• Title/Summary/Keyword: Distribution Automation System (DAS)

Search Result 68, Processing Time 0.022 seconds

Application of Algorithm for Improving FI Error in DAS (배전자동화 시스템의 FI 오류에 대한 개선 알고리즘 적용)

  • Lim, Il-Hyung;Choi, Myeon-Song;Yun, Jun-Seok;An, Tae-Pung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1025-1033
    • /
    • 2010
  • This paper proposes a method to improve and analysis error cause of FI(Fault Indicator) information to be used for detecting fault section in distribution automation system. FI error cause is made by consideration fault current magnitude and time. So, a new method to prevent FI error is proposed to include fault current magnitude, time and direction. Therefore, it's considered network environments that grounded and ungrounded network in distribution automation system. The proposed method is proved by Matlap Simulink. By the result in this research, it's possible to quickly restoration, supplying stability and reliability power to customer.

Joint use application of the CATV transmission line in DAS (CATV 전송로를 공용하는 배전자동화시스템)

  • 박종수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.994-999
    • /
    • 1993
  • To service with high quality electricity to customer, the utilities consider the DAS (Distribution Automation System) as a good means of it. The backbone of the DAS are communication and computer technique. Most of all, from the economical and functional point of view, the selection of transmission media for system communication is the key factor to achieve a successful DAS. In this paper author propose the method of the DAS communication which share its channel with CATV transmission line and analyze the effect.

  • PDF

The Development of Application Programs for Optimal Feeder Operation Through Distribution Automatic System

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jeong, Mi-Ae
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.42-47
    • /
    • 2004
  • This paper presents the various application programs for the Distribution Automation System (DAS) of the Korea Electric Power Corporation (KEPCO)'s distribution system. These programs are developed to allow for optimal operation in the areas of feeder automation, relay coordination, loss minimization and so on. They are single line diagram auto creation programs for the feeder, service restoration program, protection coordination program, data error detection program, and optimal network reconfiguration program. The details of these programs are presented for validity and effectiveness.

The Development of An Improved Distribution Automation System Including Low Voltage Monitoring Function (저압 배전망 감시기능을 포함하는 개선된 배전자동화시스템 개발)

  • Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1034-1041
    • /
    • 2007
  • This paper presents the developing results of improved distribution automation system including system configuration and subsystem design, prototype hardware and software implementation, and pilot tests on the real distribution networks of Korea Electric Power Corporation (KEPCO). An integrated system is designed to combine independent system for the distribution field works with DAS; transformer monitoring, power quality monitoring, voltage monitoring, outage monitoring, etc. The communication network is hierarchically configured as main network and branch network and well-defined integrated terminal units were developed. In addition, useful host configuration and applications were developed to integrate the services with DAS or interfacing other systems. Pilot tests were performed to verify that the system enables to properly integrate the DAS and other services of the distribution network.

  • PDF

Power Quality Monitoring System Using DWB on Distribution Automation System (DWB를 이용한 배전자동화 기반의 전기품질 모니터링 시스템 구축)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.86-93
    • /
    • 2011
  • The necessity of Power Quality(PQ) Management grow bigger because the disturbance strength in power system is increasing, on the other hand, the tolerance of electrical components is reducing with widely use of the IT and digital equipments. The domestic management standards on power quality are enacted based on the IEC standards in recent. Since the IEC standards defines the measurement and evaluation point on PQ as PCC(Point of Common Coupling) which is normally the point of penetration between customer and power company, the PQ monitoring system(PQMS) should be made to measure and manage the PQ of custom effectively. In this paper, therefore, the economical construction plan on PQMS using the wireless communication channel in distribution automation system is suggested, and the usefulness of the PQMS are shown by analyzing the PQM data with IEC standards.

A Study on the Protection Switching Mechanism for Distribution Automation System Ethernet Networks Service of Distribution Automation System (배전자동화시스템 통신서비스를 위한 이중화 통신망 보호절체 알고리즘 연구)

  • Yu, Nam-Cheol;Kim, Jae-Dong;Oh, Chae-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.744-749
    • /
    • 2013
  • The protection switching technology is widely adopted in the fiber-optical transmission equipments based on TDM(Time Division Multiplexing), such as PDH, SDH/SONET. A variety of protection switching algorithms for Ethernet networks and the progress of standardization are summarized in the document. There are several kinds of protection switching algorithms for Ethernet networks, such as STP, RSTP, MSTP and etc. However, since Ethernet signal move through detour route, it causes much time to recover. Accordingly, it is difficult to secure a usability of Ethernet networks and QOS(Quality of Service). Also, if the protection switching protocol standardized by IEEE and ITU-T is used, it remains a inherent network switching time for protection. Therefore, a specific protection switching algorithm for Ethernet are needed for seamless and stable operation of Ethernet networks service for Distribution Automation System(DAS). A reliable protection algorithm with no switching delay time is very important to implement Self-healing service for DAS. This study of FPGA based protection switching algorithm for Ethernet networks shows that in case of faults occurrence on distribution power network, immediate fault isolation and restoration are conducted through interaction with distribution equipments using P2P(Peer to Peer) communication for protection coordination. It is concluded that FPGA based protection switching algorithm for Ethernet networks available 0ms switching time is crucial technology to secure reliability of DAS.

The Development of a Distribution Automation System with an Wireless Network (무선통신망을 이용한 배전자동화시스템 개발 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2747-2749
    • /
    • 2000
  • The KEPRI has been developing the medium/small scale Distribution Automation System(DAS) that adopts wireless transmission media for exchanging information between master and remote terminals. It was concluded that Short Message Service(SMS) of Personal Communication Service(PCS) was the best wireless transmission media for the medium/small scale DAS in the last year. However. we had problem that PCS had long transmission delay. Therefore. SMS phones will be substituted with Radio Link Protocol(RLP) modems having transmission delay less than 5 seconds. This paper describes wireless networks for DAS, practical experience.

  • PDF

The Study on the Distribution Automation System using Optical Network (배전자동화 시스템용 광네트워크 구성 및 운용방안에 관한 연구)

  • Kim, Myong-Soo;Ko, Sang-Chon;Kim, Yong-Pal
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.558-560
    • /
    • 1997
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to the automation of their power plants and distribution systems, employing recent developed communication technologies. Following this trend, KEPCO has installed optical communication links along its power distribution lines and at the same time, has exhausted much efforts to implement its own Distribution Automation Systems(DAS) in possible early date. This paper presents some of initial design efforts toward KEPCO's DAS at KEPRI.

  • PDF

Distributed Restoration Solution Algorithm Improving Reliability in Intelligent Distribution Management System (신뢰성이 향상된 배전지능화 시스템의 복구해 알고리즘)

  • Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1651-1657
    • /
    • 2009
  • In this paper, restoration solution algorithm to improve reliability better than restoration system of DAS(Distribution Automation System) is proposed in IDMS(Intelligent Distribution Management System). A strategy of IDMS restoration system to improve reliability and efficiency is proposed by analysis restoration system in DAS. Restoration sequence algorithm, distributed restoration solution algorithm considering a characteristic and a suitable restoration solution algorithm in IDMS are proposed. In the case study, algorithms have testified with example distribution network by C language

A Study on the Protective Coordination of Distribution Automation System under Loop Operation (배전자동화 계통의 루프 운전시 보호협조에 관한 연구)

  • Lee, Hee-Tae;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1281-1286
    • /
    • 2009
  • As a general radial configuration of power distribution system, the various researches have being studied to change a radial configuration to network one such as smart, intelligent and micro grid for loop operation. If a radial configuration changes to network, protective coordination comes to the biggest problem. When a typical protective algorithm is applied to loop distribution system protection, the interrupted section is expanded, therefore, reliability grows worse. This paper presents the new protective method being able to apply to loop distribution system with Distribution Automation System (DAS) which separate the minimal faulted section. Through contingency analysis of the sustained and momentary fault, we analyzed the influence for radial configuration and loop configuration using interrupted area and proved the effectiveness of proposed method.