• Title/Summary/Keyword: Distributed power generation system

Search Result 440, Processing Time 0.028 seconds

The Study of Optimized Combustion Tuning Method for Fossil Power Plant (발전용 보일러의 최적연소조정기법에 대한 실험적 연구)

  • Jung, Jae-Jin;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.45-52
    • /
    • 2009
  • Fossil power plants firing lower grade coals or equipped with modified system for $NO_x$ controls are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. In order to develop a on-line combustion tuning system, field test was conducted at operating power boiler. During the field test the exhaust gases' $O_2,\;NO_x$ and CO was monitored by using a spatially distributed monitoring grid located in the boiler's high temperature vestibule and upper convective rear pass region. At these locations, the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. using these monitored information we can improving combustion at every point within the furnace, therefore the boiler can operate at reduced excess $O_2$ and gas temperature deviation, reduced furnace exit gas temperature levels while also reducing localized hot spots, corrosive gas conditions, slag or clinker formation and UBC. Benefits include improving efficiency, reducing $NO_x$ emissions, increasing output and maximizing availability. Discussion concerning the reduction of greenhouse gases is prevalent in the world. When taking a practical approach to addressing this problem, the best way and short-term solution to reduce greenhouse gases on coal-fired power plants is to improve efficiency. From this point of view the real time optimized combustion tuning approach is the most effective and implemented with minimal cost.

An Enhanced Instantaneous Circulating Current Control for Reactive Power and Harmonic Load Sharing in Islanded Microgrids

  • Lorzadeh, Iman;Abyaneh, Hossein Askarian;Savaghebi, Mehdi;Lorzadeh, Omid;Bakhshai, Alireza;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1658-1671
    • /
    • 2017
  • To address the inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids (MGs) with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on the active compensation of circulating voltage drops is proposed in this paper. Using the proposed strategy, reactive power and harmonic currents are shared accurately and proportionally without knowledge of the feeder impedances. Since the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having a remarkable effect on the amplitude or quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminals of the units. In addition, accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to MGs. The effects of communication failures and latency on the performance of the proposed strategy are also explored. The design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase MG are provided to validate the effectiveness of the proposed control method.

Demand Response Program Using the Price Elasticity of Power Demand (전력수요의 가격탄력성을 이용한 수요반응 프로그램)

  • Yurnaidi, Zulfikar;Ku, Jayeol;Kim, Suduk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.76.1-76.1
    • /
    • 2011
  • With the growing penetration of distributed generation including from renewable sources, smart grid power system is needed to address the reliability problem. One important feature of smart grid is demand response. In order to design a demand response program, it is indispensable to understand how consumer reacts upon the change of electricity price. In this paper, we construct an econometrics model to estimate the hourly price elasticity of demand. This panel model utilizes the hourly load data obtained from KEPCO for the period from year 2005 to 2009. The hourly price elasticity of demand is found to be statistically significant for all the sample under investigation. The samples used for this analysis is from the past historical data under the price structure of three different time zones for each season. The result of the analysis of this time of use pricing structure would allow the policy maker design an appropriate incentive program. This study is important in the sense that it provides a basic research information for designing future demand response programs.

  • PDF

Improved Phase and Harmonic Detection Scheme using Fast Fourier Transform with Minimum Sampling Data under Distorted Grid Voltage (최소 샘플링의 고속푸리에 변환을 이용한 비정상 계통의 향상된 위상추종 및 고조파 검출 기법)

  • Kim, Hyun-Sou;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • In distributed generation systems, a grid-connected inverter should operate with synchronization to grid voltage. Considering that synchronization requires the phase angle of grid voltage, a phase locked loop (PLL) scheme is often used. The synchronous reference frame phase locked loop (SRF-PLL) is generally known to provide reasonable performance under ideal grid voltage. However, this scheme indicates performance degradation under the harmonic distorted or unbalanced grid voltage condition. To overcome this limitation, this paper proposes a phase and harmonic detection method of grid voltage using fast Fourier transform (FFT). To reduce the calculation time of FFT algorithm, minimum sampling data is taken from the voltage measurement to determine the phase angle and the magnitude of harmonic components. An experimental test setup for a grid-connected inverter system has been constructed. By comparative simulations and experiments under various abnormal grid voltage conditions, the proposed scheme has been proven to effectively track the phase angle of the grid voltage.

Fuzzy Droop Control considering SOC Balancing of BESSs (다수 BESS의 SOC Balancing을 고려한 퍼지 드룹 제어)

  • Han, Seong-Geun;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.616-622
    • /
    • 2015
  • A microgrid which is composed of distributed generation systems, energy storage systems and loads is operated in the grid-connected mode and in the islanded mode. Especially, in the islanded mode, a microgrid should maintain frequency in the allowed range. The frequency is decided by a balance between power supply and power demand. In general, the frequency is controlled by using battery energy storage systems (BESSs) in the microgrid. Especially, droop control is applied to controlling BESSs in the microgrid. Meanwhile, over-charging and deep-discharging of BESS in operation and control cause life-shortening of batteries. In this paper, a fuzzy droop control is proposed to change droop gains adaptively by considering state of charge (SOC) of BESSs to improve the life cycle of the battery. The proposed fuzzy droop control adjusts droop gains based on SOC of BESSs in real time. In other to show the performance of the proposed fuzzy droop control, simulation based on Matlab/Simulink is performed. In addition, comparison of the convention droop control and the proposed fuzzy droop control is also performed.

Equivalent Grid Impedance Estimation Method Using Negative Sequence Current Injection in Three-Phase Grid-connected Inverter (3상 계통 연계형 인버터의 역상분 전류 주입을 이용한 계통 등가 임피던스 추정 기법)

  • Park, Chan-Sol;Song, Seung-Ho;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.526-533
    • /
    • 2015
  • A new algorithm is proposed for the estimation of equivalent grid impedance at the point of common coupling of a grid-tie inverter output. The estimated impedance parameter can be used for the improvement of the performance and the stability of the distributed generation system. The estimation error is inevitable in the conventional estimation method because of the axis rotation due to PLL. In the conventional estimation error, the d-q voltage and current are used for the calculation of the impedance with active and reactive current injections. Conversely, in the proposed algorithm, the negative sequence current is injected, and then the negative sequence voltage is measured for the impedance estimation. As the positive and negative sequence current controller is independent and the PLL is based on the positive sequence component only, the estimation of the equivalent impedance can be achieved with high accuracy. Simulation and experimental results are compared to validate the proposed algorithm.

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

A Study on Operation Characteristics of Planar-type SOFC System Integrated with Fuel Processor (연료개질기를 연계한 고체 산화물 연료전지 시스템의 운전 특성에 관한 연구)

  • Ji Hyun-Jin;Lim Sung-Kwang;Yoo Yung-Sung;Bae Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.731-740
    • /
    • 2006
  • The solid oxide fuel cell (SOFC) is expected to be a candidate for distributed power sources in the next generation, due to its high efficiency and high-temperature waste heat utilization. In this study, the 5-cell SOFC stack was operated with pure hydrogen or reformed gas at anode side and air at cathode side. When stack was operated with diesel and methane ATR reformer, the influence of the $H_2O/C,\;O_2/C$ and GHSV on performance of stacks have been investigated. The result shows that the cell voltage was decreased with the increase of $H_2O/C$ and $O_2/C$ due to the partial pressure of fuel and water, and cell voltage was more sensitive to $O_2/C$ than $H_2O/C$. Next, the dynamic model of SOFC system included with ATR reformer was established and compared with experimental data. Based on dynamic model, the operation strategy to optimize SOFC-Reformer system was suggested and simulated.

Flexible and Lined Segment Tunnel for Underground Compressed Air Energy Storage(CAES) (복공식 압축공기 지하저장을 위한 가변성 분할 라이닝 터널기술)

  • Kim, Hyung-Mok;Rryu, Dong-Woo;Chung, So-Keul;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.19 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Flexible and lined segment air-tight tunnelling technology for Compressed Air Energy Storage-Gas Turbine(CAES-G/T) power generation was introduced. The distinguished characteristics of the air-tight tunnel system can be summarized by two facts. One is that the high inner pressure due to compressed air is sustained by surrounding rock mass with allowing sufficient displacement of lining segment. The other is that the air-tightness of storage tunnel was enhanced by adopting a specially designed rubber sheet. The flexible lined air-tight underground tunnel can be constructed at a comparatively shallow depth and near urban area so that the locally distributed CAES-G/T power generation can be accomplished. In addition, this air-tight tunnelling technology can be applied to a variety of energy underground storage tunnels such as Compressed Natural Gas(CNG), Liquifed Petroleum Gas(LPG), DeMethyl Ether(DME) etc.

Development of a Coordinated Voltage Regulation Scheme in Distribution Networks with Multiple Distributed Generations (협조 제어를 이용한 분산전원 연계 배전계통의 전압조정 방식 개발)

  • Oh, Yun-Sik;Cho, Kyu-Jung;Kim, Min-Sung;Kim, Ji-Soo;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1309-1316
    • /
    • 2017
  • As penetration level of Distributed Generations (DGs) on weak distribution networks gets higher, voltage rise problem can often occur due to reverse power which is not expected in conventional distribution networks. It, however, cannot be effectively solved by using conventional voltage regulating devices such as On-Load Tap Changers (OLTCs), Step Voltage Regulators (SVRs) because those do not consider the presence of DGs when determining relevant setting parameter for voltage regulation. This paper presents a scheme for voltage regulation using coordinated control between OLTC and DGs which can actively participate in the regulation. The scheme decides which device should be operated first based on the characteristics of regulating devices, in order to prevent unnecessary operation of output changes of DG and excessive tap changing operation of OLTC. Computer simulations considering daily irradiation of PV and load curve are performed by using MATLAB Simulink and performance comparison between the presented scheme and conventional ones is also made. It can be concluded from simulation results that the scheme presented is very effective to regulate voltages in distribution networks with multiple DGs.