• Title/Summary/Keyword: Distance measuring system

Search Result 449, Processing Time 0.026 seconds

Personalized Cooling Management System with Thermal Imaging Camera (열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.782-785
    • /
    • 2021
  • In this paper, we propose a personalized cooling management system with thermal imaging camera. The proposed equipment uses a thermal imaging camera to control the amount of cold air and the system according to the difference between the user's skin temperature before and after the procedure. When the skin temperature is abnormally low, the cold air supply is cut off to prevent the possibility of a safety accident. It is economical by replacing the skin temperature sensor with a thermal imaging camera temperature measurement, and it can be visualized because the temperature can be checked with the thermal image. In addition, the proposed equipment improves the sensitivity of the sensor that measures the distance to the skin by calculating the focal length by using a dual laser pointer for the safety of a personalized cooling management system to which a thermal imaging camera is applied. In order to evaluate the performance of the proposed equipment, it was tested in an externally accredited testing institute. The first measured temperature range was -100℃~-160℃, indicating a wider temperature range than -150~-160℃(cryo generation/USA), which is the highest level currently used in the field. In addition, the error was measured to be ±3.2%~±3.5%, which showed better results than ±5%(CRYOTOP/China), which is the highest level currently used in the field. The second measured distance accuracy was measured as below ±4.0%, which was superior to ±5%(CRYOTOP/China), which is the highest level currently used in the field. Third, the nitrogen consumption was confirmed to be less than 0.15 L/min at the maximum, which was superior to the highest level of 6 L/min(POLAR BEAR/USA) currently used in the field. Therefore, it was determined that the performance of the personalized cooling management system applied with the thermal imaging camera proposed in this paper was excellent.

MARGINAL FIDELITY AND FRACTURE STRENGTH OF IN-CERAM CROWNS ACCORDING TO VARIOUS RESIN CEMENTS (접착재의 종류에 따른 In-Ceram 도재관의 변연적합도와 파절강도에 관한 연구)

  • Lim, Ju-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.888-899
    • /
    • 1998
  • In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fidelity according to type of resin cement and measuring position, and to evaluate fracture strength according to type of resin cement. In this study, twenty seven In-Ceram crowns were fabricated on the metal master die of prepared maxillary right central incisor and devided into three groups. All specimens were cemented with Panavia 21 (group PV), Super-bond (group SB) and Lute-it (group LI) on the metal master die. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of metal master die by using a stereomicroscope (SZ-ST, Olympus, Japan). Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the metal master die. For the mesurement of fracture strength, lingual surfaces of cemented specimens were loaded at a distance of 1mm from incisal edge by using the Autograph S-2000 (Shimadzu, Japan). The results of marginal fidelity and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows: 1. In comparison of marginal fidelity according to the measuring points, there was no significant difference. 2. The marginal fidelity according to the type of resin cement was decreased in order of group $LI\;(63.75{\mu}m),\;SB\;(77.78{\mu}m),\;PV\;(86.53{\mu}m)$, and there was significant difference between group LI and PV (p<0.05). 3. The fracture strength according to the type of resin cement was showed descending order of group $LI\;(60.00kg/cm^2),\;SB\;(56.80kg/cm^2),\;PV\;(56.11kg/m^2)$, but there was no significant difference.

  • PDF

3D Head Modeling using Depth Sensor

  • Song, Eungyeol;Choi, Jaesung;Jeon, Taejae;Lee, Sangyoun
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.13-16
    • /
    • 2015
  • Purpose We conducted a study on the reconstruction of the head's shape in 3D using the ToF depth sensor. A time-of-flight camera (ToF camera) is a range imaging camera system that resolves distance based on the known speed of light, measuring the time-of-flight of a light signal between the camera and the subject for each point of the image. The above method is the safest way of measuring the head shape of plagiocephaly patients in 3D. The texture, appearance and size of the head were reconstructed from the measured data and we used the SDF method for a precise reconstruction. Materials and Methods To generate a precise model, mesh was generated by using Marching cube and SDF. Results The ground truth was determined by measuring 10 people of experiment participants for 3 times repetitively and the created 3D model of the same part from this experiment was measured as well. Measurement of actual head circumference and the reconstructed model were made according to the layer 3 standard and measurement errors were also calculated. As a result, we were able to gain exact results with an average error of 0.9 cm, standard deviation of 0.9, min: 0.2 and max: 1.4. Conclusion The suggested method was able to complete the 3D model by minimizing errors. This model is very effective in terms of quantitative and objective evaluation. However, measurement range somewhat lacks 3D information for the manufacture of protective helmets, as measurements were made according to the layer 3 standard. As a result, measurement range will need to be widened to facilitate production of more precise and perfectively protective helmets by conducting scans on all head circumferences in the future.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

Geometric Evaluation of Patient-Specific 3D Bolus from 3D Printed Mold and Casting Method for Radiation Therapy

  • An, Hyun Joon;Kim, Myeong Soo;Kim, Jiseong;Son, Jaeman;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.32-38
    • /
    • 2019
  • Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

Roundabout Design and Intervehicle Distance Measure for V2X-based Autonomous Driving (V2X 기반 자율운전을 위한 회전교차로 설계 및 차간 거리 측정)

  • Hwang, Jae-Jeong;Oh, Seok-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.83-89
    • /
    • 2021
  • To improve the performance of self-driving cars, the introduction of V2X, a communication technology that connects vehicles, infrastructure, and vehicles, is essential. Even if traffic information of the other vehicle is known, the structure of the intersection and a distance calculation algorithm are required for accurate calculations at roundabouts. This paper proposes a design algorithm for a rotating intersection and implemented in Matlab that complies with the national design rules and enables accurate calculations. Assuming the roundabout and the entrance/exit path to be a circle, a method for measuring the distance between vehicles at an arbitrary point was proposed using the horizontal shift of the entrance circle to the main circle. The algorithm could be used in fully autonomous vehicles by designing a roundabout suitable for the terrain by arbitrarily varying the angle between branches and the radius of curvature of the entrance and exit roads, and transmitting a warning signal when a collision between two driving vehicles is expected.

Design of Wireless Transmission System on Distance Measurement (거리측정 무선 전송 시스템 설계)

  • Kim, Young-Keun;Yeom, Jin-Su;Ryu, Kwang-Ryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.101-104
    • /
    • 2008
  • 현대에 컴퓨터를 기반으로 무선으로 데이터를 측정하고 제어하는 device들이 보편화 되어있으며, 낮은 가격으로 높은 성능을 낼 수 있는 device들이 각광 받고 있다. 그리고 산업 환경에서 유선 이용이 불가능한 곳이나 직접 사람이 들어갈 수 없는 위험한 장소와 거리 측정할 때 Zigbee 통신 Solution을 이용한다면 공간의 제약 없이 컴퓨터로 데이터를 분석 처리할 수 있다. Zigbee 통신은 기존의 RF나 bluetooth등에 비해 전력 소모에서 효율적이고 battery 사용을 장시간 사용할 수 있는 장점을 가지고 있다. 또한 시스템 구현 비용이 아주 저렴하기 때문에 네트워크에 많은 노드들을 설치 할 수 있다. 이에 본 논문에서 구현한 거리 측정 무선 송/수신 시스템은 여러 개의 LMC(Laser Measuring Control)와 이에 상응하는 여러 개의 Slave Zigbee에서 하나의 Master Zigbee 까지 무선으로 데이터를 송신한다. Master Zigbee는 LMC에서 측정한 데이터들을 수신 받아 컴퓨터로의 처리를 하고자 하였다.

  • PDF

Improved Single Channel Speech Enhancement Algorithm Using Adaptive Postfiltering

  • Song, Eunwoo;Kang, Hong-Goo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.122-125
    • /
    • 2011
  • In real environment, background noise exists everywhere and degrades the performance of system. To reduce this distortion, a speech enhancement algorithm can be very useful and variety methods have been proposed. In this paper, we propose a postfilter to improve the performance of optimally modified log-spectral amplitude (OM-LSA) estimator. Proposed algorithm uses the formant postfilter to minimize perceptual distortion caused by background noise. We adjust an emphasizing parameter which is varied by spectral flatness and first reflection coefficient. The performance of the proposed algorithm is evaluated by measuring the log-spectral distance (LSD) and the perceptual evaluation of speech quality (PESQ) score. The test results show the improvement of proposed algorithm compared to conventional OM-LSA.

  • PDF

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

The Effect of Gas Pressure on the c-axis Orientation Properties of Co-Cr Thin Film prepared by Sputtering Method (스퍼터링법으로 제작된 Co-Cr 박막에서 가스 압력이 c-축 배향성에 미치는 영향)

  • Choi, Sung-Min;Son, In-Hwan;Kim, Jae-Hwan;Kim, Kyung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.761-763
    • /
    • 1998
  • In this paper, Co-Cr thin films which are known for a excellent perpendicular magnetic recording media were prepared. Changing target- substrate distance, Ar gas pressure and arriving atoms, the incident angle and c-axis orientation properties by using the facing targets sputtering system. We evaluated the c-axis dispersion angle by measu ring half-height width with Micro area X-Ray Diffractometer, measured the thickness of thin film with Ellipsometer. The magnetic properties were compared measuring in-plane squareness and perpendicular coercivity with vibrating sample Magnetometer.

  • PDF