• Title/Summary/Keyword: Distance Instrument

Search Result 165, Processing Time 0.024 seconds

A Study on Mechanism Stated Number of Electro-Optical Distance Measuring Instrument (광파측거의의 기계정수에 관한 연구)

  • Lee, Y.H.;Mun, D.Y.
    • Journal of Korean Port Research
    • /
    • v.5 no.2
    • /
    • pp.77-84
    • /
    • 1991
  • This paper is compared with fourier series and least square polynomial fit and interpolation to mechanism stated number in electro-optical distance measuring instrument. Systematic instrumental errors occurring in electro-optical systems include uncertainties in the position of the electrical center of the transmitter, uncertainties in the effective center of the reflectors. frequency drift and instrument nonlinearity. Microwave systems are affected by uncertainties in the electrical centers of the master and remote units and by a phenomenon called group swing or reflection. As the result of this study, mechanism stated number will be used as verification of electro0optical measuring instrument to distance measurement.

  • PDF

A Human Factors Study in Instrument Panel Layout of the Korean Air Force Aircraft. (항공기 계기판의 적정배열을 위한 인간공학적 연구)

  • Park Jong-Sun
    • Journal of the military operations research society of Korea
    • /
    • v.2 no.1
    • /
    • pp.127-143
    • /
    • 1976
  • The purpose of this thesis is to study the optimal arrangement of aircraft instrument panels through the human factors approach. Human factors engineering is the process of effectively fitting the human component to the machine component in any man-machine system. The human factors. are especially important to an aircraft pilot who must constantly shift his attention between the instrument panel within the cockpit and the surrounding area of the aircraft. The preliminary part of this study is to find the general patterns of the Korean pilot's eye movements during their various flying maneuvers, and which instruments require the most attention while in flight. It is assumed that all pilots have a general pattern of eye movement when observing the aircraft instrument panel and that an optimum arrangement would be to minimize the eye travel distance between instruments. In this thesis the arrangements of instruments is taken to be the independent variable and the eye travel distance between instruments the dependent variable. la order to compile the information necessary for this study, sixty Korean Air Force pilots were interviewed and requested to complete information forms. These information forms listed various flying maneuvers and listed each instrument used on the instrument panel. The compilation of the information on these completed forms listed the instruments most frequently used by the pilots. The second part of this study was to determine the optimum instrument arrangement. It was necessary to study the various number of possible arrangements of instruments depending upon the number of instruments involved. Therefore, these instruments are grouped by two major functions, The flight instruments were subdivided into three groups, and the engineering instruments were subdivided into six groups. With this subdivision we arrive at the possible number of arrangements of 4,320. Through the simulation method, total eye travel distance for each of these 4,320 arrangements is calculated and the arrangement which appears to be of optimum distance between the most frequently used aircraft instruments is determined. The results of this study indicate that the optimum distance between instruments would be 33,028cm and that the corresponding distance of the instrument panel now being used is 34,288cm. Therefore, an increased efficiency of $3.8\%$ would be realized if the existing aircraft instrument panel were re-arranged according to layout proposed in this thesis.

  • PDF

The Development of Industrial Laser Range Finder (산업용 레이저 거리 계측기 개발)

  • Bae, Young-Chul;Kim, Chun-Suk;Kim, Yi-Gon;Cho, Eui-Joo;Park, Jong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.4
    • /
    • pp.228-235
    • /
    • 2007
  • The Laser distance instrument in past was used mainly with military affairs and the helicopter loaded measures the distance with target and the firing body used in the tank. The military suspicion case measurement distance was scope until of tens km consequently from possibility km and under measuring should have been boiled the low error was 5m husbands and wives. Like this under using should have been boiled the effort was being continued the Laser distance instrument will be able to apply in industry from the present paper hereupon and the usability developed verified.

  • PDF

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

The Development of High Precision Laser Finder Ranger (고정밀 레이저 거리 계측기 개발에 관한 연구)

  • Bae, Young-Chul;Kim, Yi-Gon;Park, Jong-Bae;Kim, Chun-Suk;Cho, Eui-Joo;Seo, Jonh-Joo;Azimov, U.B.;Koo, Young-Duk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2296-2302
    • /
    • 2006
  • In this paper, we propose a development technique of high precision laser finder ranger within instrument distance 1km, instrument error less than 1 m by using pulse time of flight method in the 5m unit instrument and heterodyne method in the within Am unit. These propose methods can be more advanced to measurement velocity and more highly precision distance instrument not affected the strength of light. We also validate this usefulness.

Precise Baseline Measurement and Computation of Correction Factor For EDM Instrument Calibration (EDM 장비의 검교정을 위한 정밀 기선장 관측 및 보정계수 산정)

  • 조재명;윤홍식;이원춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.83-89
    • /
    • 2004
  • The electronic distance measurement instrument, first introduced in the 1950s has, since those early days, undergone continual refinement. Rapid advances in related technologies have provided lighter, smaller and more precise equipment. Understanding for the principle, the standardized observation technique and the precision of EDM instrument is mostly important to improve the quality and the reliability of by-product in the field of engineering and industrial surveying. Simple and accurate calibration is regularly and periodically necessary to maintenance the precision of EDM instrument. This paper describes the calculated example of zero error and scale error as a correction of EDM by applying the least square method to baseline observations. Here we deals also with the testing criteria for precision instrument testing according to different types of EDM instruments.

  • PDF

Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery (최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상)

  • Park, Hyeonjun;Won, Jongseok;Park, Jaeheung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.12
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

디지탈 화상처리를 이용한 사출제품의 길이측정용 시각검사시스템 개발에 관한 연구

  • 김재열;박환규;오보석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.281-285
    • /
    • 1996
  • In this paper, I made visual inspection system using Vision Board and it is consist of an illuminator (a fluorescent lamp), image input device(CCD(Charge)Coupled Device) camera), image processing system(Vision Board(FARAMVB-02), image output device(videomonitor, printer), a measuring instrument(TELMN1000). Length measurement by visual inspection system is used 100mm gauge block instead of calculating distance between camera and object, it measured horizontal and vertical length factor from 400mm to 650mm by increasing 50mm. In this place, measured horizontal and vertical length factor made use of length measurement of a injection. A measuring instrument used to compare a measured length of a injection visual inspection system with it. In conclusion, length measurement of a injection compared a measuring instrument withvisual inspecion system using length factor of 100mm guage block. Maximum error of length compared two devices a measuring instrument with visual inspection system is 0.55mm. And operation program is made up Borland C++ 3.1. By changing, it is applied to various uses.

  • PDF

Development of Measurement System for Deflection of the Large-Size FPD (대면적 평판 디스플레이용 유리기판의 처짐 측정장치 개발)

  • Kim, Sook-Han;Kim, Tae-Sik;Lee, Eung-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • There is a need to enlarge the mother glass substrate in OLED to raise its productivity and to realize OLED TV. On the other hand, some difficulties may arise regarding the deflection of a large glass substrate during its handling operation due to its thinness $(0.5\sim0.7t)$, which is not even enough to allow it to stand its own mass. This thesis proposes a conceptual plan for the application of the clamping- and bending-end conditions to the glass substrate handler. To verify proposed plan, the non-contact 3 dimensional measuring instrument is developed. The composition of the 3 dimensional measuring instrument measures shape of the product using X-Y stage robot and laser distance sensor. X-Y stage robot and laser distance sensor are controlled by LabVIEW language. To calibrate measuring instrument, the direction conversion of the Euler angle was used. In order to confirm deflection of the glass substrate, the experiment was carried out at the bending end boundary condition and the proposed effect was verified.

  • PDF

위성 영상 탑재체에 관련된 영상품질 인자의 특성

  • Cho, Young-Min
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.66-74
    • /
    • 2002
  • The characteristics of the satellite image quality parameters driven by satellite imaging instrument are investigated. Since the satellite image is directly produced by the satellite imaging instrument, the satellite image quality depends on the imager performance highly. This is why the imager performance parameters are considered as an important part of the satellite image quality parameters. The imager performance parameters consist of spectral band parameters, ground sample distance(GSD) parameters, swath width parameters, imager Modulation Transfer Function (MTF), imager Signal to Noise Ratio(SNR), radiometric response characteristics parameters, pixel registration, and imager calibration.

  • PDF