Precise Baseline Measurement and Computation of Correction Factor For EDM Instrument Calibration

EDM 장비의 검교정을 위한 정밀 기선장 관측 및 보정계수 산정

  • 조재명 (성균관대학교 토목환경공학과) ;
  • 윤홍식 (성균관대학교 토목환경공학) ;
  • 이원춘 (성균관대학교 토목환경공학과)
  • Published : 2004.04.01

Abstract

The electronic distance measurement instrument, first introduced in the 1950s has, since those early days, undergone continual refinement. Rapid advances in related technologies have provided lighter, smaller and more precise equipment. Understanding for the principle, the standardized observation technique and the precision of EDM instrument is mostly important to improve the quality and the reliability of by-product in the field of engineering and industrial surveying. Simple and accurate calibration is regularly and periodically necessary to maintenance the precision of EDM instrument. This paper describes the calculated example of zero error and scale error as a correction of EDM by applying the least square method to baseline observations. Here we deals also with the testing criteria for precision instrument testing according to different types of EDM instruments.

Keywords