• Title/Summary/Keyword: Disposal system

Search Result 803, Processing Time 0.035 seconds

The Permeability Characteristic of Z-Type Sheet Pile Joints under Water Sealing Conditions (지수조건에 따른 Z형 강널말뚝 연결부의 투수특성)

  • Chung, Ha-Ik;Lee, Yong-Soo;Hong, Seung-Seo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

Performance as a factor in the Contemporary Fashion Show - focus on the Paris and London collections Since the 1990s - (현대 패션쇼에 나타난 퍼포먼스적 요소 - 1990년 이후 파리, 런던 컬렉션을 중심으로 -)

  • 장안화;박민여
    • Journal of the Korean Society of Costume
    • /
    • v.51 no.4
    • /
    • pp.71-80
    • /
    • 2001
  • Since the beginning of the 90's, Fashion shows appear to be a type of performance form of art combining with other areas to visually entertain the viewers. This can be explained by the modern tendency to escape from society which requires formality and complicated lifestyles. Fashion shows take place in a scene Influenced by the idea of post-modernism which redefines the definition of space. A church, old factory, unoccupied ground, subway stations, or even place like a waste disposal are used as a setting. The stage set is no longer the T shape run way and the procinium arch has disappeared. The gap between audience and stage has diminished and theatrical element is added to the fashion performance by using viewers living and working environments as setting of the show. The human relation with machine based on the cutting edge technology such as the stage automation, robots and mist making sprinkler system introduces new elements with spontaneity and detailed planning in the stage performance. Music also plays an Important role in attracting viewers. The sound track covers house music to techno music. Instead of music being abstract, folks orchestral music, choirs, piano. even live concert performed by pop artist provide the liveliness of the fashion show. And the catwalk itself is a performance. Model needs to be well trained as the capable talent who can handle sensitive gestures, facial expressions, dancing and choreography. The improvisatorial interaction between audience and model lead to audience participation. Models now range from pop star, ordinary people, handicapped people, to elderly and so on. John Galliano introduced the theatrical factors for the fashion show and Alexander Mcqueen approached the fashion show as the visual art of communication. Hussein Chalayan utilized high technology skewing futurism as if in a magic show. Today the Fashion show tends to be a total performance which includes audience participation, impromptu, and that break the limitation that fashion shows previously had. This will lead the fashion industry in opening new horizon of its own.

  • PDF

A PRACTITIONERS VIEW OF MODERN DEVELOPMENTS IN LIMNOLOGY

  • IMBERGER J.;ANTENUCCI J.;BRUCE L.;DUCAS A.;EWING T.;FEAVER S.;HIPSEY M.;IMERITO A.;LAM C.;MORILLO S.;ROMERO J.;SHIMIZU K.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.09a
    • /
    • pp.11-12
    • /
    • 2005
  • With the great advances in process understanding, sensor and instrumentation technology and modelling capability it is important to ask what if any practical benefits can the lake manager and operator look forward to. Here, we examine some of the more important problems facing operators of drinking reservoirs, hydro-lakes and lakes used predominantly for recreation and the environment. In drinking reservoirs the main problems originate from increased loadings of nutrients leading to increased biomass and biomass that may give rise to toxins, of anthropogenic chemicals such as metals and synthetic organics and of pathogens of different types. Hydro-lakes are predominantly plagued by problems arising from low oxygen levels in the hypolimnion and in recreational and environmentally sensitive lakes the biggest challenge for the operator is to maintain an existing or establish a new trophic hierarchy or protect the water body from foreign species. The control variables that are at an operator's disposal are the choice of lake water level, the modification of the water colunm stratification via a de-stratification system, the modification of the lake flow path with flow intervention. curtains, intervention in the catchments to modify the loadings flowing into a lake, manipulation of the trophic chain with introduction of new species and chemical dosing, the latter being of marginal use in a large lake. Each of these options is cost effective under certain-circumstances. We endeavour to provide a users guide for their application and show how, especially new instrumentation and modelling methodologies may be used to achieve an effective intervention.

  • PDF

Blasting Impact by the Construction of an Underground Research Tunnel in KAERI (한국원자력연구소내 지하처분연구시설 건설에 따른 발파 영향)

  • Kwon Sang-Ki;Cho Won-Jin;Kim Deug-Su
    • Explosives and Blasting
    • /
    • v.23 no.4
    • /
    • pp.1-18
    • /
    • 2005
  • The underground research tunnel, which is under construction in KAERI for the validation of HLW disposal system, is excavated in a granite rock by drill&blasting. In order not to disturb the operation at the research facilities including Hanara reactor by the blasting for the excavation of $6m{\times}6m$ tunnel, a test blasting at the site was performed. Using the vibration equation derived from the test blasting, it was possible to predict the vibration at different locations at KAERI and to conclude that the blasting design would meet the design criteria at the major facilities in KAERI. The noise and vibration generated by the main blasting were continuously measured. In the case of vibration, the measured values were lower than the predicted one from the vibration equation. It is, therefore, concluded that the influence of blasting work for the construction of 280m long research tunnel on the major facilities in KAERIl would be insignificant.

Economic Feasibility Study for Commercial Production of Bio-hydrogen (해양바이오수소개발 사업의 상업생산을 위한 예비경제성평가)

  • Park, Se-Hun;Yoo, Young-Don;Kang, Sung Gyun
    • Ocean and Polar Research
    • /
    • v.38 no.3
    • /
    • pp.225-234
    • /
    • 2016
  • This project sought to conduct an economic feasibility study regarding the commercial production of bio-hydrogen by the marine hyperthermophilic archaeon, Thermococcus onnurineus NA1 using carbon monoxide-containing industrial off-gas. We carried out the economic evaluation of the bio-hydrogen production process using the raw material of steel mill by-product gas. The process parameter was as follows: $H_2$ production rate was 5.6 L/L/h; the conversion of carbon monoxide was 60.7%. This project established an evaluation criterion for about 10,000 tonne/year. Inflation factors were considered as 3%. The operating costs were recalculated based on prices in 2014. The total investment required for development was covered 30% by capital and 70% by a loan. The operation cost for the 0.5-year test and integration, and the cost for the first three months in the 50% production period were considered as the working capital in the cost estimation. The costs required for the rental of office space, facilities, and other related costs from the construction through to full-scale production periods were considered as continuing expenses. Materials, energy, waste disposal and other charges were considered as the operating cost of the development system. Depreciation, tax, maintenance and repair, insurance, labor, interest rate charges, general and administrative costs, lubrication and miscellaneous expenses were also calculated. The hydrogen price was set at US$ 4.15/kg for the economic evaluation. As a result, the process was considered to be economical with the payback period of 6.3 years, NPV of 18 billion Won and IRR of 26.7%.

Development of an environment-friendly moving aquatic animal rendering equipment and evaluation of fertilizer value for recycling of fish waste (친환경 이동식 수산생물 폐사체 처리장치 개발 및 재활용을 위한 비료 가치 평가)

  • Kim, Jae-Ok;Kim, Su-Mi;Seo, Jung-Soo;Jee, Bo-Young;Kim, Young-Jae;Kwon, Mun-Gyeong
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.97-101
    • /
    • 2020
  • Although aquaculture production rates grown over the years, aquatic animal diseases occur every year which causes substantial economic losses. When an aquatic animal is infected with an aquatic animal pathogen it is either incinerated or buried according to the aquatic life disease control act. Although these methods prevent the spread of disease, it is not environment friendly. Here, we developed an aquatic animal rendering equipment for disposal of fish waste which is environment-friendly and efficient. Also, fertilizer components of fish waste were evaluated value for recycling. The mobile rendering equipment was designed for field operation and/or high temperature and pressure system, oil and water separator, and shredding drying apparatus. During the experiment (July-2016 to November-2016), a total of 53,824 kg fish waste was collected, and 29,216 kg compost of rendering by-product was made. Also, compost made from viral (Viral hemorrhagic septicemia virus) infected fish did not reflect any detectable pathogen. The concentration of nitrogen, phosphorus, and organic matter in the fish waste compost were 2.17%, 26.98%, and 92.44%, respectively. The results suggest that fish waste used in this study was decomposed efficiently as per the official standard for fertilizer product. This equipment can be useful for efficient inactivation of the aquatic animal pathogenic agents and recycling of the fish waste in an environment-friendly manner.

Hydrogeological Properties of Geological Elements in Geological Model around KURT (KURT 지역에서 지질모델 요소에 대한 수리지질특성)

  • Park, Kyung Woo;Kim, Kyung Su;Koh, Yong Kwon;Choi, Jong Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.3
    • /
    • pp.199-208
    • /
    • 2012
  • To develop site characterization technologies for a radioactive waste disposal research in KAERI, the geological and hydrogeological investigations have been carried out since 1997. In 2006, the KURT (KAERI Underground Research Tunnel) was constructed to study a solute migration, a microbiology and an engineered barrier system as well as deeply to understand geological environments in in-situ condition. This study is performed as one of the site characterization works around KURT. Several investigations such as a lineament analysis, a borehole/tunnel survey, a geophyscial survey and logging in borehole, were used to construct the geological model. As a result, the geological model is constructed, which includes the lithological model and geo-structural model in this study. Moreover, from the results of the in-situ hydraulic tests, the hydrogeological properties of elements in geological model were evaluated.

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.

Technology Trends in Spent Nuclear Fuel Cask and Dry Storage (사용후핵연료 운반용기 및 건식저장 기술 동향)

  • Shin, Jung Cheol;Yang, Jong Dae;Sung, Un Hak;Ryu, Sung Woo;Park, Yeong Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.110-116
    • /
    • 2020
  • As the management plan for domestic spent nuclear fuel is delayed, the storage of the operating nuclear power plant is approaching saturation, and the Kori 1 Unit that has reached its end of operation life is preparing for the dismantling plan. The first stage of dismantling is the transfer of spent nuclear fuel stored in storage at plants. The spent fuel management process leads to temporary storage, interim storage, reprocessing and permanent disposal. In this paper, the technical issues to be considered when transporting spent fuel in this process are summarized. The spent fuels are treated as high-level radioactive waste and strictly managed according to international regulations. A series of integrity tests are performed to demonstrate that spent fuel can be safely stored for decades in a dry environment before being transferred to an intermediate storage facility. The safety of spent fuel transport container must be demonstrated under normal transport conditions and virtual accident conditions. IAEA international standards are commonly applied to the design of transport containers, licensing regulations and transport regulations worldwide. In addition, each country operates a physical protection system to reduce and respond to the threat of radioactive terrorism.

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF