• 제목/요약/키워드: Displacement Calibration

검색결과 120건 처리시간 0.023초

기름 유량표준장치의 개발 및 측정 불확도에 관한 연구 (A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.

지상 레이져 매핑시스템 구현을 위한 4S-Van 시스템 설계 (The design of 4S-Van for implementation of ground-laser mapping system)

  • 김성백;이승용;김민수
    • Spatial Information Research
    • /
    • 제10권3호
    • /
    • pp.407-419
    • /
    • 2002
  • 본 연구에서는 레이져 매핑 시스템 구현을 위한 4S-Van 시스템의 설계에 대해 논하였다. 레이져 센서는 대상물의 3차원값을 기존의 사진측량에 비해 정확하고 빠르게 측정가능한 센서이다. 4S-Van 에 장착된 레이져의 광의 발사위치와 방향을 결정하기 위해 약결합 방식의 (D)GPS/INS 통합 알고리즘을 사용하였다. 레이져 매핑을 실현하기 위한 기초적이고 예비적인 실험으로서 현 시스템에 장착된 센서를 고려하여(D)GPS/INS 통합 알고리즘의 성능테스트와 장착된 CCD 카메라의 보정을 위해 근거리사진측량 기법중의 하나인 self-calibration 기법을 통해 외부표정요소와 내부표정요소를 획득하였다. 3대의 레이져 스케너를 동시에 작동시켜 데이터간의 상호보정을 통해 정밀도 향상을 시도하였다. 향후 레이져 데이터와 CCD 영상을 통해 확보된 질감 정보를 이용하여 컴퓨터 공간상에 지형지물에 대해 3차원 시각화 및 도시모델링 구축에 활용할 계획이다.

  • PDF

Absolute Distance Measurements Using the Optical Comb of a Femtosecond Pulse Laser

  • Jin, Jong-Han;Kim, Young-Jin;Kim, Yun-Seok;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권4호
    • /
    • pp.22-26
    • /
    • 2007
  • We describe a new way of implementing absolute displacement measurements by exploiting the optical comb of a femtosecond pulse laser as a wavelength ruler, The optical comb is stabilized by locking both the repetition rate and the carrier offset frequency to an Rb clock of frequency standard. Multiwavelength interferometry is then performed using the quasi-monochromatic beams of well-defined generated wavelengths by tuning an external cavity laser diode consecutively to preselected light modes of the optical comb. This scheme of wavelength synthesizing allows the measurement of absolute distances with a high precision that is traceable to the definition of time. The achievable wavelength uncertainty is $1.9{\times}10^{-10}$, which allows the absolute heights of gauge blocks to be determined with an overall calibration uncertainty of 15 nm (k = 1). These results demonstrate a successful industrial application of an optical frequency synthesis employing a femtosecond laser, a technique that offers many possibilities for performing precision length metrology that is traceable to the well-defined international definition of time.

Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장 (Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

Piezoelectric PZT Cantilever Array Integrated with Piezoresistor for High Speed Operation and Calibration of Atomic Force Microscopy

  • Nam, Hyo-Jin;Kim, Young-Sik;Cho, Seong-Moon;Lee, Caroline-Sunyong;Bu, Jong-Uk;Hong, Jae-Wan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.246-252
    • /
    • 2002
  • Two kinds of PZT cantilevers integrated with a piezoresistor have been newly designed, fabricated, and characterized for high speed AFM. In first cantilever, a piezoresistor is used to sense atomic force acting on tip, while in second cantilever, a piezoresistor is integrated to calibrate hysteresis and creep phenomena of the PZT cantilever. The fabricated PZT cantilevers provide high tip displacement of $0.55\mu\textrm{m}/V$ and high resonant frequency of 73 KHz. A new cantilever structure has been designed to prevent electrical coupling between sensor and PZT actuator and the proposed cantilever shows 5 times lower coupling voltage than that of the previous cantilever. The fabricated PZT cantilever shows a crisp scanned image at 1mm/sec, while the conventional piezo-tube scanner shows blurred image even at $180\mu\textrm{m}/sec$. The non-linear properties of the PZT actuator are also well calibrated using the piezoresistive sensor for calibration.

Design and calibration of a wireless laser-based optical sensor for crack propagation monitoring

  • Man, S.H.;Chang, C.C.;Hassan, M.;Bermak, A.
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1543-1567
    • /
    • 2015
  • In this study, a wireless crack sensor is developed for monitoring cracks propagating in two dimensions. This sensor is developed by incorporating a laser-based optical navigation sensor board (ADNS-9500) into a smart wireless platform (Imote2). To measure crack propagation, the Imote2 sends a signal to the ADNS-9500 to collect a sequence of images reflected from the concrete surface. These acquired images can be processed in the ADNS-9500 directly (the navigation mode) or sent to Imote2 for processing (the frame capture mode). The computed crack displacement can then be transmitted wirelessly to a base station. The design and the construction of this sensor are reported herein followed by some calibration tests on one prototype sensor. Test results show that the sensor can provide sub-millimeter accuracy under sinusoidal and step movement. Also, the two modes of operation offer complementary performance as the navigation mode is more accurate in tracking large amplitude and fast crack movement while the frame capture mode is more accurate for small and slow crack movement. These results illustrate the feasibility of developing such a crack sensor as well as point out directions of further research before its actual implementation.

Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사 (The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer)

  • 조승일;김성부;이종규;이용봉;이두희
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.

모아레 간섭계와 모델교정법을 이용한 솔더 합금의 점소성 물성치 역추정 (Inverse Estimation of Viscoplastic Properties of Solder Alloy Using Moir$\acute{e}$ Interferometry and Computer Model Calibration)

  • 강진혁;이봉희;주진원;최주호
    • 한국전산구조공학회논문집
    • /
    • 제24권1호
    • /
    • pp.97-106
    • /
    • 2011
  • 본 연구에서는 전자패키지에 사용되는 솔더 재료의 점소성 물성치를 규명하였다. 이를 위해 전자패키지와 비슷한 변형을 보이는 시편을 제작하였고 모아레 간섭계를 이용하여 열사이클 하에서의 변형을 측정한 뒤 시편의 굽힘 변위와 솔더의 전단 변형률을 구하였다. 시편에 대해 점소성 유한요소해석을 실시하였고 해석 결과가 실험 결과에 일치하도록 물성치를 역으로 추정하였다. 실험에서 발생한 측정오차와 실험횟수 부족 등의 불확실성을 고려하기 위해 컴퓨터 모델 교정법을 이용하였고, 그 결과 추정된 물성치는 평균 및 신뢰구간으로 표현되었으며, 이로 인한 유한요소해석 결과도 마찬가지로 평균 및 신뢰구간으로 표현되었다.

지진관측자료의 효과적인 활용에 관한 고찰 (Best Use of the Measured Earthquake Data)

  • 연관희;박동희;김성주;최원학;장천중
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.36-43
    • /
    • 2001
  • In Korea, we are absolutely short of earthquake data in good quality from moderate and large earthquakes, which are needed fur the study of strong ground motion characteristics. This means that the best use of the available data is needed far the time being. In this respect, several methods are suggested in this paper, which can be applied in the process of data selection and analysis. First, it is shown that the calibration status of seismic stations can be easily checked by comparing the spectra from accelerometer and velocity sensor both of which are located at the same location. Secondly, it is recommended that S/N ratio in the frequency domain should be checked before discarding the data by only look of the data in time domain. Thirdly, the saturated earthquake data caused by ground motion level exceeding the detection limit of a seismograph are considered to see if such data can be used for spectrum analysis by performing numerical simulation. The result reveals that the saturated data can still be used within the dominant frequency range according to the levels of saturation. Finally, a technique to minimize the window effect that distorts the low frequency spectrum is suggested. This technique involves detrending in displacement domain once the displacement data are obtained by integration of low frequency components of the original data in time domain. Especially, the low frequency component can be separated by using discrete wavelet transform among many alternatives. All of these methods mentioned above may increase the available earthquake data and frequency range.

  • PDF

240 kV 고전압 변성기 국가표준 시스템 구축 (Establishment of National Standard System for 240 kV High Voltage Transformer)

  • 정재갑;권성원;이상화;강전홍;김명수;한상길;김윤형;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.164-169
    • /
    • 2008
  • National standard system for calibrating voltage transformer(VT) up to primary voltage of 240 kV have been established in 2005. The system consists of voltage source, regulating unit, VT testing unit, standard VT, VT under test and VT burden. To verify and validate the performance for 240 kV VT calibration system, the comparison with the National Measurement Institute of Australia(NMIA) has been performed using same VTs. The comparison results of the VTs mesured at the Korea Research Institute of Stansdards and Science(KRISS) are consistent with those measured at NMIA within 0.002 % for ratio error and 0.14 min for phase displacement in the primary voltage ranges of Vp = 3300 V - 22000 V with a secondary voltage of Vs = 110 V.