• Title/Summary/Keyword: Disinfection treatment

Search Result 372, Processing Time 0.028 seconds

Disinfection Methods of Pruning Scissor for Preventing Transmission of Fire Blight (과수 화상병 전염 차단을 위한 전정 가위 소독 방법)

  • Yeon-Jeong Lim;Hyeonheui Ham;Mi-Hyun Lee;Woohyung Lee;Yong Hwan Lee
    • Research in Plant Disease
    • /
    • v.30 no.2
    • /
    • pp.194-198
    • /
    • 2024
  • Pathogens of fire blight can survive for a long time on pruning tools, etc., and fire blight can be spread through agricultural implements. In particular, in Korea, pruning is frequently performed to remove flowers, immature fruits, and succulent shoots, and this farm work is known to be a major factor of the spread of fire blight. Therefore, in this study, in order to completely sterilize pathogens on pruning shears, we verified the disinfection effect of disinfectants distributed domestically and used them to identify an effective disinfection method. When disinfecting by immersion after inoculating Erwinia amylovora TS3128 on the scissor blade, 70% ethanol and 1% and 0.2% sodium hypochlorite sterilized immediately 10 sec after immersion, while 30% chlorine dioxide showed little disinfection effect. When disinfecting by spraying, 70% ethanol sterilized bacteria 1 sec after spraying, but 1% and 0.2% sodium hypochlorite disinfected bacteria after 10 and 60 sec, respectively. After cutting the naturally disease occurring branches five and 100 times, the bacteria were not hardly sterilized in immersion treatment in 70% ethanol for 30 sec but perfectly disinfected over 60 sec. Considering these results, pruning shears should be disinfected by frequently immersing them in 70% ethanol for at least 60 sec during pruning work in the field.

Awareness and practice of dental unit waterline management in dental hygienist (치과위생사의 치과 유니트 수관관리에 대한 인식과 실천도)

  • Lee, Seong-Sook;Kim, Dong-Ae;Song, Sun-Young;Kim, Mi-Yeon;Shim, Ha-Na
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.507-516
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the awareness and practice of dental unit waterline management in dental hygienist. Methods: A self-reported questionnaire was completed by 377 dental hygienists in Seoul and Gyeonggido from March 2 to April 30, 2015. The data were collected by direct visit and informed consent was received after explanation of the study. The questionnaire consisted of general characteristics of the subjects, awareness of dental waterline, practice of dental waterline, and implementation of dental waterline disinfection. Data were analyzed using SPSS 12.0 program. Results: There was a significant correlation between the dental unit waterline disinfection and the appropriateness of the water used for dental treatment(p<0.01, p<0.001). The handpiece was the most commonly used device before treatment and the majority of the subjects answered that they didn't take water out of ultrasonic scaler and air-water syringe on a daily basis. Conclusions: The majority of the dental hygienists did not know the right understanding and proper practice of dental unit waterline management. To reduce the dental device contamination, the continuing education of waterline management should be done for the dental hygienists.

Factors Affecting Chemical Disinfection of Drinking Water

  • Lee, Yoon-jin;Nam, Sang-ho;Jun, Byong-ho;Oh, Kyoung-doo;Kim, Suk-bong;Ryu, Jae-keun;Dionysiou, Dionysios D.;Itoh, Sadahiko
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.126-131
    • /
    • 2004
  • This research sought to compare chlorine, chlorine dioxide and ozone as chemical disinfectants of drinking water, with inactivation of total coliform as the indicator. The inactivation of total coliform was tested against several variables, including the dose of disinfectant, contact time, pH, temperature and DOC. A series of batch processes were performed on water samples taken from the outlet of a settling basin in a conventional surface water treatment system that is provided with the raw water drawn from the mid-stream of the Han River. Injection of 1 mg/L of chlorine, chlorine dioxide and ozone resulted in nearly 2.4, 3.0 and 3.9 log inactivation, respectively, of total coliform at 5 min. To achieve 99.9 % the inactivation, the disinfectants were required in concentrations of 1.70, 1.00 and 0.60 mg/L for chlorine, chlorine dioxide and ozone, respectively. Bactericidal effects generally decreased as pH increased in the range of pH 6 to 9. The influence of pH change on the killing effect of chlorine dioxide was not strong, but that on ozone and free chlorine was sensitive. The activation energies of chlorine, chlorine dioxide and ozone were 36,053, 29,822 and 24,906 J/mol for coliforms with inactivation effects being shown in the lowest orders of these.

Chlorine Disinfection in Water Treatment Plants and its Effects on Polyamide Membrane (수처리장에서의 염소살균처리가 폴리아마이드 분리막에 미치는 영향)

  • Jun, Byung-Moon;Yun, Eun-Tae;Han, Sang-Woo;Nguyen, Thi Phuong Nga;Park, Hyung-Gyu;Kwon, Young-Nam
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.88-99
    • /
    • 2014
  • Demand for water is increasing due to rapid population growth and increased industrial activities. Membrane technologies have attracted most attention as a promising advanced technology for the supply of sustainable water resources. Chemical and structural properties of polyamide membranes, one of the most widely used membranes in water treatment plant, has been reported to be affected by residual chlorine dissolved in water after chlorine disinfection. This paper focuses on the chlorine speciation at various solution pHs and change of surface properties/performance of polyamide membranes due to the chlorine exposure.

SURFICIAL DISINFECTION OF ESCHERIACHIA COLI-CONTAMINATED PLAYGROUND SOIL BY UV IRRADIATION

  • Kim, Jae-Eun;Kim, Tong-Soo;Cho, Shin-Hyeong;Cho, Min;Yoon, Je-Yong;Shea, Patrick J.;Oh, Byung-Taek
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.64-71
    • /
    • 2007
  • The necessity of disinfecting playground soil is an important issue, because pathogenic protozoa, bacteria, and parasite eggs remain viable for several months and can infect children. UV irradiation has been used to decontaminate water but its effectiveness on soil is unclear. We determined the efficacy of UV radiation for inactivation of an indicator bacteria, E. coli (strain ATCC 8739), on playground soil. While 99% inactivation of E. coli in the soil was readily achieved by UV radiation within 55 min at $0.4\;mW\;cm^{-2}$, complete inactivation was not achieved, even after prolonged treatment at $4\;mW\;cm^{-2}$. This was attributed to the irregular surface of the soil. A small number of E. coli escaped the UV radiation because they were situated in indentations or under small particles on the soil surface. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) confirmed that the surface characteristics of the soil is the major limiting factor in the inactivation of E. coli by UV radiation. Thus UV treatment may not be adequate for disinfecting some soils and should be carefully evaluated before being used on playground soils.

Evaluation of the performance and the removal characteristics of natural organic matter in a modular mobile water production system (모듈형 이동식 물생산 시스템 운전 성능 및 자연 유기물 제거 거동 평가)

  • Hwang, Yuhoon;Yang, Philje;Song, Jimin;Hong, Minji;Choi, Changhyung;Ko, Seokoh;Kim, Dogun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.55-65
    • /
    • 2018
  • It is necessary to develop a mobile water production system in order to provide stable water supply in case of disasters such as floods or earthquakes. In this study, we developed a modular mobile water production system capable of producing water for various uses such as domestic water and drinking water while improving applicability in various raw water sources. The water production system consists of three stages of filtration (sand filtration - activated carbon filtration - pressure filtration) to produce domestic water and an additional reverse osmosis process to produce drinking water. In laboratory and field experiments, the domestic water production system showed excellent treatment efficiency for particulate matter, but showed limitations in the treatment of dissolved substances such as dissolved organic matter. In addition, ultraviolet irradiation was considered as additional disinfection step, because it does not form precipitates of manganese oxides after disinfection. Reverse osmosis process was added to increase the removal efficiency of dissolved substances and the treated water satisfied drinking water quality standards. Fluorescence analysis of dissolved organic matter showed that the fulvic acid-like substances in raw water was successfully removed in the reverse osmosis process. The mobile water production system developed in this study is expected to be used not only in water supply in case of disaster, but also widely used in islands and rural area.

Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique (정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가)

  • Son, Hee-Jong;Hwang, Young-Do;Ryu, Dong-Choon;Jung, Chul-Woo;Lee, Gun;Son, Hyeng-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.

Piggery Waste Treatment using Improved MLE Process in Full-Scale (수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

Removal of Algogenic Organic Matter in Drinking Water Treatment Process (정수처리공정에서 조류유래 유기물질의 제거)

  • Park, Se-Jin;Cha, Il-Kwon;Yoon, Tai-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Algae causes not only the eutrophication of lake, but also the deterioration of drinking water process. Especially, algogenic organic matters(AOM) are assumed as disinfection by-products(DBPs) precursors like humic and fulvic acids. In this study, it was investigated the characteristics changes of algogenic organic matter(AOM) by prechlorination and coagulation treatment. Evaluation of enhanced coagulation and applicability of UV oxidation process were also evaluated as the drinking water treatment system for the eutrophicated water source. prechlorination was effective process for algae removal but caused releasing of dissolved organic matter(DOC) into water due to the destruction of algae's cell. In coagulation treatment with Fe(III) coagulant, reaction pH is an important factor for the removal of AOM and triholomathanes(THMs). At pH 5, removal efficiency of DOC and THMs were dramatically improved by 50% and 28%, respectively, in comparison with the conventional coagulation treatment at about pH 7. Photo-Fenton($UV/H_2O_2/Fe^{3+}$) process among the UV oxidations is the most effective system to remove AOM, but its removal efficiency was lower than that of enhanced coagulation treatment at pH 5.

Effective Heat Treatment Techniques for Control of Mung Bean Sprout Rot, Incorporable into Commercial Mass Production

  • Lee, Jung-Han;Han, Ki-Soo;Kim, Tae-Hyoung;Bae, Dong-Won;Kim, Dong-Kil;Kang, Jin-Ho;Kim, Hee-Kyu
    • The Plant Pathology Journal
    • /
    • v.23 no.3
    • /
    • pp.174-179
    • /
    • 2007
  • Seedlot disinfection techniques to control mung bean sprout rot caused by Colletoricum acutatum and C. gloeosporioides were evaluated for commercial production scheme. Soaking seedlots in propolis (100 X) and ethanol (20% for 30 min) appeared promising with control values of 85.5 and 80.8 respectively, but still resulted in up to 20% rot incidence. None of the C. acutatum conidia survived through hot water immersion treatment (HWT) for 10 min at temperatures of 55, 60 and $65^{\circ}C$, whereas the effective range of the dry heat treatment (DHT) was $60-65^{\circ}C$. Tolerance of mung bean seedlot, as estimated by hypocotyl elongation and root growth, was lower for HWT than for DHT. Germination and growth of sprouts were excellent over the range of $55-65^{\circ}C\;at\;5^{\circ}C$ intervals, except for HWT at $65^{\circ}C$ for 5 min. At this marginal condition, heat damage appeared so that approximately 2% of seeds failed to sprout to normal germling and retarded sprouts were less than 5% with coarse wrinkled hypocotyls. These results suggested that DHT would be more feasible to disinfect mung bean seedlots for commercial sprout production. Heat treatment at above ranges was highly effective in eliminating the epiphytic bacterial strains associated with marketed sprout rot samples. HWT of seedlot at 55 and $60^{\circ}C$ for 5 min resulted in successful control of mung bean sprout rot incidence with marketable sprout quality. DHT at 60 and $65^{\circ}C$ for 30 min also gave good results through the small-scale sprouting system. Therefore, we optimized DHT scheme at 60 and $65^{\circ}C$ for 30 min, considering the practical value of seedlot disinfection with high precision and accuracy. This was further proved to be a feasible and reliable method against anthracnose incidence and those bacterial strains associated with marketed sprout rot samples as well, through factory scale mung bean sprout production system.