• Title/Summary/Keyword: Disinfection facility

Search Result 28, Processing Time 0.029 seconds

A Study on Water Quality Management Methods of Waterscape Facilities in Accordance Legislation of Water Quality Criteria (수질기준 법제화에 따른 물놀이형 수경시설의 수질관리방안 연구)

  • Na, Kyung-Ho;Yong, Jeong-Ju;Kim, Ji-Soo;Byeon, Ju-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.487-493
    • /
    • 2017
  • This study was conducted to propose measures of water quality management as the water criteria for waterscape facilities which have been highlighted as alternatives to wading pools in summer season was legislated. The number of public waterscape facilities has reached 290 sites in Gyeounggi province and 971 sites in South Korea in 2017. The water tank capacity of 80.3 % public waterscape facilities was less than $100m^3$. Facilities with disinfection system were only 6.5 % and facilities with filtration function were also very low at 6.9 %. Most of the waterscape facilities, about 93%, are expected to be vulnerable to complying with revised water quality criteria because they have to be disinfected by handling. Chlorine disinfectants, which are more persistent than ozone or ultraviolet sterilization methods, are more preferred. However, care should be taken when adding disinfectans because hypochlorous acid, which is an effective component of chlorine disinfectant, remains after the disinfection, but it is easily decomposed with time. For this study, ${\bigcirc}{\bigcirc}$ park floor fountain with a capacity of $63m^3$ was selected and the amount of free residual chlorine concentration was measured by injecting a certain amount of chlorine bleach. As a result, it took 5 hours to decrease from the water quality standard of 4 mg/L to 0.04 mg/L. If the waterscape facility is operated for 7 to 8 hours, the chlorine bleach should be re-injected after 5 hours. In addition, the problem of pH increase due to the input of chlorine disinfectant is expected, and the neutralization method using vinegar was proposed.

Development of a Concentration Prediction Model for Disinfection By-product according to Introduce the Advanced Water Treatment Process in Water Supply Network (고도정수처리에 따른 상수도 공급과정에서의 소독부산물 농도 예측모델 개발)

  • Seo, Jeewon;Kim, Kibum;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.421-430
    • /
    • 2017
  • In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

Effects of Food Safety Management Support of Center for Children's Foodservice Management on Foodservice Facilities for Children in Busan Area (부산 일부 지역의 어린이 급식시설에 대한 어린이급식관리지원센터의 위생.안전 관리 지원 효과)

  • Kim, Sung-Hye;Oh, Eung-Young;Han, Jin-Suk
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.24 no.2
    • /
    • pp.261-274
    • /
    • 2014
  • The purpose of this study was to examine the effects of food safety management support in the Center for Children's Foodservice Management (CCFSM) on foodservice facilities for children in Busan area. We assessed the status of hygiene and safety practices of institutional and non-institutional foodservice on a quarterly basis by using an inspection checklist for food hygiene and safety developed by dieticians from February to December in 2013. The subjects were 103 children's foodservices, including 37 institutional and 66 non-institutional foodservices. Inspection checklist consisted of nine categories with 39 checklists; general characteristics, personal hygiene, ingredient control, menu planning, cooking processing control, serving management, washing, disinfection and storage control, and environment and safety management. The average score of each field (pre-supporting/post-supporting) in institutional foodservice was 0.56/0.92 for personal hygiene, 0.55/0.87 for ingredient control, 0.76/0.97 for menu planning, 0.53/0.89 for processing control, 0.27/0.67 for serving management, 0.47/0.91 for washing, disinfection and storage control, and 0.61/0.91 for environment management and 0.64/0.94 for safety management. In non-institutional foodservice, the average score of each field (pre-supporting/post-supporting) was 0.49/0.80 for personal hygiene, 0.52/0.75 for ingredient control, 0.78/0.97 for menu planning, 0.42/0.76 for processing control, 0.32/0.61 for serving management, 0.57/0.88 for washing, disinfection and storage control, and 0.46/0.82 for environment management and 0.73/0.88 for safety management. The average scores of all categories (pre-supporting/post-supporting) were 0.57/0.91 in institutional foodservice and 0.53/0.82 in non-institutional foodservice. The effects of management support in CCFSM on institutional foodservice were higher than those of non-institutional foodservice. Based on these results, we found that management support in CCFSM on foodservice facilities for children had a significantly positive effect on status of hygiene and safety practice regardless of foodservice facility size.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

Epidemiological Investigation of an Outbreak of Hepatitis A at a Residential Facility for the Disabled, 2011

  • Lim, Hyun-Sul;Choi, Kumbal;Lee, Saerom
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.2
    • /
    • pp.62-73
    • /
    • 2013
  • Objectives: An outbreak of hepatitis A occurred at a residential facility for the disabled in July 10, 2011. This investigation was carried out to develop a response plan, and to find the infection source of the disease. Methods: A field epidemiologist investigated the symptoms, vaccination histories, living environments, and probable infection sources with 51 residents and 31 teachers and staff members. In July 25, 81 subjects were tested for the hepatitis A virus antibody, and specimens of the initial 3 cases and the last case were genetically tested. Results: Three cases occurred July 10 to 14, twelve cases August 3 to 9, and the last case on August 29. Among the teachers and staff, no one was IgM positive (on July 25). The base sequences of the initial 3 and of the last case were identical. The vehicle of the outbreak was believed to be a single person. The initial 3 patients were exposed at the same time and they might have disseminated the infection among the patients who developed symptoms in early August, and the last patient might have, in turn, been infected by the early August cases. Conclusions: The initial source of infection is not clear, but volunteers could freely come into contact with residents, and an infected volunteer might have been the common infection source of the initial patients. Volunteers' washing their hands only after their activity might be the cause of this outbreak. Although there may be other possible causes, it would be reasonable to ask volunteers to wash their hands both before and after their activities.

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.

A study on the management status of public small-scale sewage treatment facilities and the improvement (마을하수도 운영실태 및 개선방안)

  • Shin, Dae-Yewn;Bae, Chul-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.55-64
    • /
    • 2008
  • In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.

Application of HACCP for Hygiene Control to Jabchae in Team Foodservice Facility (잡채를 중심으로 한 단체급식시설의 위생개선을 위한 HACCP 적용에 관한 연구)

  • 이선애;박경준;강성태
    • Culinary science and hospitality research
    • /
    • v.9 no.4
    • /
    • pp.81-97
    • /
    • 2003
  • The purpose of this study was to evaluate hazard factors in the steps of production, holding and assembly and service of jabchae that were served by contracted management in school meal foodservice. And method of control with the Hazard Analysis Critical Control Point (HACCP)program was suggested. The hazard factors in jabchae product had come from the temperature, time, growth of microbiological equipment and utensils. Almost of raw materials, prepreparation and storage, cooking, holding, serving established the critical control point. It has shown that the microbiological quality of raw materials for jabchae was a little inferior at the time of receiving based on the total plate count(10$^3$∼10 $^{5}$ ), coliform(0∼10$^3$). However microbiological quality become acceptable level by washing and a few disinfection method. Microbiological growth has increased in 3hr at room temperature up to 5.1${\times}$10$^2$ after preparation of jobchae. In conclusion, it is extremly important to reduce hoiding and serving time and to avoid treating food within the danger zone for food safeness. In addition, the prevention of cross-contamination during mixing the ingredients with improper equipment and with insanitary treatments by workers was also important to keep the food safe in this foodservice facility.

  • PDF

Application of HACCP for Hygiene Control in University Foodservice Facility - Focused on Vegetable Dishes (Sengchae and Namul) - (대학급식시설의 위생관리개선을 위한 HACCP 적용에 관한 연구 - 생.숙채류를 중심으로 -)

  • 허영수;이복희
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.3
    • /
    • pp.293-304
    • /
    • 1999
  • The purpose of this study was to evaluate the microbiological quality, and to assure the hygienic safety of the food production in the university food service facility located in Seoul in accordance with the Hazard Analysis Critical Control Point(HACCP) concepts. In the hygienic state assessment of kitchen, it has revealed that it was very important to remove water from the kitchen floor and to establish standard method for disinfection of cooking utensils. And foodservice workers were required to have training program for the safe handling of food and utensils since they did treat food without hygienic gloves. The kitchen layout had to be improved because the near distance of table with heating unit and shelf might cause the growth of microorganisms when prepared food was kept on the shelf. In terms of the timetemperature measurement and microbiological quality assessment during each of the food production phases, most of sengchae (raw vegetable dish) and namul (cooked vegetable dish) were treated within danger zone for food safeness ($5~60^{\circ}C$). It has shown that the microbiological quality of raw materials was very much inferior at the time of receiving based on the TPC($10^{5}~10^{7}$), coliform($10^{3}~1O^{6}$), which was not acceptable level(TPC:$10^{6}$, coliform:$10^{3}$) suggested by Solberg. Microbiological growth has increased in the both of sengchae and namul considerably during most of food production phase. Therefore, it is extremely important to reduce holding and serving time and to avoid treating food within the danger zone for food safeness. In addition, the prevention of cross-contamination during mixing the ingredients with improper equipments and with insanitary treatments by workers was also important to keep the food safety in this speciqic university foodservice facility.

  • PDF