• Title/Summary/Keyword: Discrepancy

Search Result 1,903, Processing Time 0.029 seconds

A study on Teacher Perception and Classroom Practice of Practical Problem-Focused Home Economics Instruction (실천적 문제 중심 가정과 수업에 대한 교사의 인식과 실행에 관한 연구)

  • Go, Mi-Young;Yu, Nan-Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.23 no.1
    • /
    • pp.159-176
    • /
    • 2011
  • The purpose of this study was to investigate 1) how the middle school Home Economics teachers perceive the importance of the practical problem-focused instruction, 2) how often they perform the instruction, and 3) what they require for the implementation the instruction. Data were collected from 150 Home Economics teachers via e-mail survey and from 6 Home Economics teachers' face-to-face interviews. Descriptive statistics including frequency, percentage, average, and standard deviation, and the results of such analyses as ANOVA, T-test, and correlation were reported using SPSS/win 10.1. The results of this research were as follows: First, even though the majority of the respondents recognized the high need for practical problem-focused instruction, only a small portion of the respondents reported that they performed that instruction in the classroom. There was no correlation between the perception of the need for practical problem-focused instruction and the degree of performance of practical problem-focused instruction. Secondly, the of performance of practical problem-focused instruction was significantly different depending on the years of teaching experience and the subject that the teachers majored in. Job satisfaction had positive correlations with the perception of the need for practical problem-focused instruction and the degree of performance of practical problem-focused instruction. Thirdly, the more teachers shared information and materials with colleagues, the better they tended to be at practical problem-focused instruction. On the other hand, insufficient time for their instruction and a deficiency in understanding the rationale of the instruction were pointed out as barriers to classroom practice. The respondents answered that long-term training programs on the philosophical foundation of practical problem-focused instruction, materials related to the instruction as well as additional credits for Home Economics are most critical to reduce the discrepancy between the teacher perception and the classroom practice of practical problem-focused instruction.

  • PDF

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

DENTAL CROWDING AND ITS RELATIONSHIP TO TOOTH SIZE AND ARCH DIMENSION IN KOREAN (한국인에서 치아 및 악궁의 크기와 총생의 관계)

  • Lee, Nan-Young;Hong, Sung-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.510-521
    • /
    • 2006
  • This investigation was undertaken to examine the extent to which tooth size and arch dimension each contribute to dental crowding. The sample included 50 subjects with well aligned dentition (25 males, 25 females) and those of 40 subjects with gross dental crowding(20 males, 20 females). Plaster model and digital model made from alginate impression taken at the one visit. Tooth size, arch length, arch perimeter, intercanine width and intermolar width was measured on the plaster and digital models. The findings in this study lead to the following conclusions. 1. In maxilla, the mesiodistal diameters of lateral incisor and premolars of the crowded group were significantly larger than those of the normal occlusion group (P<0.05). 2. In mandible, the mesiodistal diameters of central incisor, canine and premolars of crowded group were significantly larger than those of the normal occlusion group (P<0.05). 3. In maxilla, arch perimeter and intermolar width of crowded group were significantly smaller than normal occlusion group but intercanine width of crowded group were larger than normal occlusion group (P<0.05). There was no significantly difference in arch length (P>0.05). 4. In mandible, arch perimeter of crowded group was smaller than normal occlusion group(P<0.05). There were no difference in arch length intermolar width and intercanine width (P>0.05) 5. In the analysis of correlation coefficients of arch length discrepancy with variables, arch perimeter, intermolar width and mesiodistal width of 2nd premolar showed positive correlations in maxilla. 6. There was a significant difference between tooth width measurements made by the 2 methods, with all the digital model measurement larger than plaster model measurements (P<0.05) : the magnitude of the differences does not appear to be clinically relevant. 7. In the analysis for reproducibility, the plaster model measurement was showed lower degree of correlation between 1st and 2nd measurement than digital model.

  • PDF

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

Parasympathetic Modulation Plays a Key Role in Initiation of Paroxysmal Atrial Fibrillation

  • Lee, Won-Jae;Shin, Dong-Gu;Hong, Geu-Ru;Park, Jong-Sun;Kim, Young-Jo
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.216-231
    • /
    • 2007
  • Background : An acceleration or deceleration of the heart rate (HR), which reflects autonomic effects, is observed before the onset of paroxysmal atrial fibrillation (PAF). The purpose of this study was to assess the discrepancy in the autonomic interactions before the onset of PAF for different patterns of change in the HR. Materials and Methods : From 105 Holter tapes with the PAF recorded, 55 episodes (42 patients, 34 men, $58{\pm}12$ years) of PAF (>5 min), preceded by a sinus rhythm for more than 1 hour, were selected and submitted to time-domain and frequency-domain HR variability analyses. Fifty-five episodes were divided into 2 groups: group A PAF (n=30) with acceleration of the HR during the last 2 minutes before the PAF and group B (n=25) with deceleration of the HR. Results : A significant linear decrease in the mean R-R interval was observed in group A ($924{\pm}30$ to $835{\pm}28ms$, $P$=0.001) and an increase from $831{\pm}32$ to $866{\pm}31ms$ in group B PAF episodes ($P$=0.046). In the frequency-domain analyses, the LF/HF ratio exhibited a progressive linear increase before the PAF in group A ($P$=0.005). The HF normalized units (HFnu) and natural logarithm-transformed HF ($In$HF) values decreased from $30.8{\pm}4.0$ to $16.1{\pm}1.8$ ($P$=0.003) and $4.49{\pm}0.25$ to $4.07{\pm}0.22$ ($P$=0.001), respectively. Contrary to the results in group A, a significant increase in the HF components (HFnu and $In$HF) (from $22.6{\pm}3.2$ to $30.2{\pm}4.0$, $P$=0.005, and $4.27{\pm}0.27$ to 4.75 0.33, $P$=0.001, respectively) and a resultant decrease in the LF/HF ratio were observed in group B PAF episodes. No significant changes were observed in the LF components in either PAF group. Conclusion : Autonomic stimuli leading to an acceleration or deceleration of the HR before the onset of AF are due to parasympathetic modulation. Parasympathetic modulation plays a key role in the initiation of PAF.

  • PDF

SOFT TISSUE CHANGES AFTER DOUBLE JAW SURGERY IN SKELETAL CLASS III MALOCCLUSION (골격성 III급 부정교합자의 양악수술후 연조직 변화의 평가)

  • Cho, Eun-Jung;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.1-16
    • /
    • 1996
  • The purpose of this study was to evaluate the amount and interrelationship of the soft and hard tissue changes after simultaneous maxillary advancement and mandibular setback surgery in skeletal Class III malocclusion. The sample consisted of 25 adult patients(13 males and 12 females) who had severe anteroposterior skeletal discrepancy. These patients had received presurgical orthodontic treatment and surgical treatment which consisted of simultaneous Le Fort I or Le Fort II osteotomy and bilateral sagittal split ramus osteotomy. The presurgical and postsurgical lateral cephalograms were evaluated. The computerized statistical analysis was carried out with SPSS/$PC^+$ program. The results were as follows. 1. The correlation of maxillary hard and soft tissue horizontal changes were high and the ratios for soft tissue to A point were $71\%$ at Sn, $67\%$ at SLS and $37\%$ at LS. 2. The correlation of mandibular hard and soft tissue horizontal changes were very high and the ratios were $84\%$ at LI, $107\%$ at ILS, $96\%$ at Pog' and $97\%$ at Gn'. 3. The correlation of mandibular hard tissue horizontal changes and soft tissue vertical changes were moderate. 4. The upper to lower lip length were increased(P<0.001). 5. The soft tissue thickness were decreased in upper lip and increased in lower lip(P<0.001). The postsurgical changes were reversely correlated with initial thickness in upper lip.

  • PDF

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.