• Title/Summary/Keyword: Discharge.charge-time

Search Result 241, Processing Time 0.026 seconds

AC PDP(Plasma Display Panel)의 방전 특성 해석

  • 황기웅;정희섭;서정현
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1997.07a
    • /
    • pp.173-176
    • /
    • 1997
  • A numerical analysis of the micro-discharge in an AC pplasma dispplay cell has been made using time-deppendent, 2-dimensional multi-fluid equations to understand the discharge pphysics of He-Xe discharge. The time deppendent distribution of the electron tempperature, densities of electrons, various ions and excited sppecies, and the effects fo the wall charge accumulated on the dielectric surface are obtained and comppared with the results of direct observation of time deppendent behavior of VUV and visible sppectra from single discharge cell observed using a gated, image intensified CCD to elucidate the discharge physics.

  • PDF

Analysis of Wall-charge behavior using V-Q Lissajous' figure in AC-PDP driving (AC-PDP 구동에 있어서 V-Q Lissajous' Figure을 이용한 벽전하 거동분석)

  • Chung, Jong-Kab;Cho, Woo-Sung;Choi, Chang-Hun;Ju, Byeong-Keon;Park, Sun-Woo;Kim, Chul-Ju;Rho, Seung-Ryong;Kim, Young-Cho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.111-115
    • /
    • 2002
  • To understand the discharge characteristics in AC-PDP, it is necessary to study on the wall charge behavior. But, it is difficult to measure the wall charge directly. In this paper, the V-Q Lissajous' figure is used to measure the wall charge indirectly and analyze the wall charge behavior. With the V-Q Lissajous' figure, the discharge characteristics of AC-PDP are studied according to vary driving conditions, such as the frequency, pulse duty ratio, and rising & falling time. As a result, the V-Q Lissajous' figure is used to measure the discharge characteristics of the AC-PDP. It is confirmed that firing initial voltage and firing final voltage for discharge are effected by the aboved variables. Related with the wall voltage generation, it is thought that the difference of the slope at the V-Q Lissajous' figure is caused by charged ions inside the dielectric layer.

  • PDF

A Study on the Characteristics of Reset Discharge in the ADS Driving Method for the PDPs (PDP의 ADS 구동방식에서의 초기화 방전특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.17-22
    • /
    • 2003
  • The priming discharge characteristic at the reset period in the ADS drive method of PDP was experimentally analyzed in this research. The amount of wall charge accumulated by the discharge and the accumulated time are unrelated to the priming pulse width. The self-erase discharge by excessive wall charge is related to the amount of wall charge by the priming discharge and this is related to space charge generated by the priming discharge. From the experimental result, in the optimized priming condition the plus width is 8$mutextrm{s}$ and the voltage is about 163V. The space charge which helps the self-erase discharge exists during about 16$mutextrm{s}$ immediately after generating the priming discharge. Therefore, it is suitable within 16$mutextrm{s}$ of the priming pluse width for the effective reset process.

An Optimal Energy Storage Operation Scheduling Algorithm for a Smart Home Considering Life Cost of Energy Storage System

  • Yan, Luo;Baek, Min-Kyu;Park, Jong-Bae;Park, Yong-Gi;Roh, Jae Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1369-1375
    • /
    • 2017
  • This paper presents an optimal operation scheduling algorithm for a smart home with energy storage system, electric vehicle and distributed generation. The proposed algorithm provides the optimal charge and discharge schedule of the EV and the ESS. In minimizing the electricity costs of the smart home, it considers not only the cost of energy purchase from the grid but also the life cost of batteries. The life costs of batteries are calculated based on the relation between the depth of discharge and life time of battery. As the life time of battery depends on the charge and discharge pattern, optimal charge and discharge schedule should consider the life cost of batteries especially when there is more than one battery with different technical characteristics. The proposed algorithm can also be used for optimal selection of size and type of battery for a smart home.

The Delay-Time Characteristics of DC Discharge in the Discharge Logic Gate Plasma Display Panel (방전논리게이트 플라즈마 디스플레이 패널의 직류방전 지연특성)

  • Ryeom, Jeong-Duk;Kwak, Hee-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 2007
  • In this research, the characteristics of the DC discharge that was the logical gate input of discharge logic gate PDP newly proposed was considered. The logical output is induced by controlling the potential difference of inter-electrode according to the discharge path in the discharge logic gate. From the experimental result the discharge time lag was shortened to 1/3 and the voltage has decreased to 1/2 in the case to apply priming discharge for improving stability of these DC discharges compared with the case when it is not applied. Moreover, after the priming discharge ends, the space charge generated by this discharge influences it up to about $30[{\mu}s]$. And, as a measured result of the influence that the space charge exerts on the DC discharge with the change in time and spatial distance, it has been understood that there is a possibility that going away spatially can slip out the influence of the discharge easily as for going away from the discharge time-wise. Therefore the conclusion that the discharge logic gates of each scanning electrode can be operated independently is obtained.

Effect of Address Discharge Characteristics by Selective Reset Method in AC Plasma Display Panel (교류형 플라즈마 디스플레이에서 선택적 초기화 방법에 의한 기입 방전 특성의 영향)

  • Cho, Byung-Gwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1004-1008
    • /
    • 2012
  • The effect of address discharge characteristics by selective reset method is investigated to prevent the weakness of address discharge in the middle of a TV-field without increase of the black luminance. To reduce black luminance in AC PDP usually, the first subfield during one TV frame adopted the conventional rising ramp-reset waveform, whereas the other subfields adopted the subsidiary reset waveform without rising ramp type. As the wall charge for the address discharge was accumulated by only the rising ramp waveform during the first reset period, the wall charge on three electrodes was disappeared as time passed and the address discharge would be weakened in the rear subfields. To prevent a reduction of the address discharge characteristics without decrease the black luminance, the modified rising ramp reset waveform was adopted only in the sixth subfield. As a result, a modified driving method could improve the address discharge characteristics compared with selective reset driving scheme with almost the same black luminance.

The Diagonosis of Treeing Breakdown Simultaneous Detection on Charge of Partial Discharge and Acoustic Emission Pulse (방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • Choi, J.K.;Kim, S.H.;Park, J.J.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1781-1783
    • /
    • 1996
  • Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with a artificial needle shape void by the charge of partial discharge and acoustic emission pulse in each phase angle area at the same time. We have analyzed the ${\Phi}-Q-n$ pattern and the insulation diagnosis of the samples using statistic operators such as charge magnitude and A.E pulse factor, skweness, kurtosis, G,C. Therefore, the relation between the charge of partial discharge and A.E pulse will be helpful and efficient to predict the breakdown just before the breakdown occure.

  • PDF

A Study on the Multi-Channel Large Capacity Charge/Discharge Formation Module (다채널 대용량 충방전기 모듈 개발에 대한 연구)

  • Lee, Jun Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • This study was developed through the secondary battery module charging/discharger possible utilization in the production process equipment circuit. The developed module is ensuring construction of efficient and productive charging and discharger through this research a limit on the yield and the price of existing single -channel charge and discharger circuit as a 5V 70A grade secondary battery Formation charge and discharger for up to 1 board 4 channels. In order to improve the sensing accuracy, through a robust differential amplifier circuit described using 16bit Analog-Digital Converter and noise was secured 16bit resolution sensing. The configuration also made demands for property Rise / Fall Time. Data Acquisition, discharge efficiency and also to fit the sink circuit temperature level for mass production.

Improved Waveform during the Addressing Period for the Improvement of the Addressing Time for AC PDPs

  • Lim, Jong-Sik;Kim, Hyun-Seok;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.511-514
    • /
    • 2004
  • ADS(Address Display period Separation) driving method has been considered to be the most appropriate driving technique for AC PDPs. However when the ADS driving method is applied to the high-resolution AC PDP, the required long addressing time often becomes a problem. In this paper, we present a new waveform for reducing the addressing time and for the stable addressing discharge. In this new waveform, a wall charge acceleration pulse is applied to the common electrode right after 80us scan time. In this way, the charge generated by the addressing discharge is accelerated to the electrodes. Experiments using the wall charge acceleration pulse showed that we could stably address an AC PDP with the scan pulses having pulse width of 1 us

  • PDF

Relation of X-ray diffraction and charge/discharge capacity Of LiMn$_2$O$_4$ cathode for Lithium ion batteries (리튬 이온 전지용 LiMn$_2$O$_4$ 정극의 X-선 회절 분석과 충방전 용량과의 관계)

  • 정인성;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.347-350
    • /
    • 1998
  • We studied relation of X-ray diffraction and charge/discharge capacity of LiMn$_2$O$_4$ cathode. LiMn$_2$O$_4$ is prepared by reacting stoichiometric mixture of LiOH.$H_2O$ and MnO$_2$ (mole ratio 1 : 2) and heating at $700^{\circ}C$, 80$0^{\circ}C$ for 24hr, 36hr, 48hr, 60hr and 72hr. Through X-ray diffraction pattern, it is analyzed that crystal structure and lattice parameter and peak ratio so on. We obtained X-ray diffraction pattern that varied lattice parameter and peak intensity by function of calcining temperature and time. Cathode active materials calcined at 80$0^{\circ}C$ for 36hr shown that (111)/(311) Peak ratio at X-ray diffraction pattern was 0.37. It means that crystal structure is formed very well in this temperature and time. In the result of charge/discharge test, cathode active material calcined at 80$0^{\circ}C$ for 36hr displayed excellent charge/discharge properties than that of cathode active materials calcined at other temperature and title. In this study, we certified that spinel structure basied cubic is formed very well at 80$0^{\circ}C$ for 36hr. In this case, (111)/(311) peak ratio at X-ray diffraction is 0.37, and charge/discharge properties is excellent than others.

  • PDF