• 제목/요약/키워드: Discharge capacity test

검색결과 244건 처리시간 0.025초

식생분포에 따른 하도의 통수능 검토를 위한 3차원 모형의 적용 (Application of Three-Dimensional Model to Evaluate Stream Discharge Capacity due to Vegetation)

  • 노준우;이진영;안기홍
    • 환경영향평가
    • /
    • 제20권1호
    • /
    • pp.37-48
    • /
    • 2011
  • Recently, the social and environmental functions of nature river are important due to the increase of expectation for river restoration. So it should be considered the effect of vegetation affecting the conveyance capacity and hydraulic resistance. However, it has not yet proposed a objective standard and modeling method to estimate the effect of conveyance capacity according to vegetaion distribution in the watercourse such as water level or velocity. Therefore, this study simulates the variations of water level and velocity using 3-dimensional hydrodynamic model, EFDC, to consider a conveyance capacity in downstream of the Soyang Reservoir. The simulation results were validated using statistical index such as F-test and T-test. As results, the water level rises about 0.01 to 0.47m and velocity difference are about -0.95m/s to 0.23m/s.

카본을 부극으로 사용하는 $LiMnO_2$ 전지의 전기화학적 특성 (Charge/Discharge Characteristics of $LiMnO_2$ Battery using Carbon as Anode Materials)

  • 김은미;임승규;김남인;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.277-278
    • /
    • 2008
  • Orthorhombic $LiMnO_2$(o-$LiMnO_2$) has attracted public attentions as a cathode materials of Lithium ion battery because it has low cost and high theoretical discharge capacity of 285mAh $g^{-1}$. In our study, o-$LiMnO_2$ is synthesized by quenching method. To verify their phase structure, X-ray diffraction is accomplished. Test cells are assembled to check electrochemical characteristics using acquired o-$LiMnO_2$ cathode and carbon anode. Charge/Discharge cycling was carried out for 50cycles. And impedance was measured at 1, 2, 5, 10, 30, 50cycle. During cycle test, the max discharge capacity was recorded 139mAh $g^{-1}$ at 10cycle.

  • PDF

풍화토지반에서 전기방전에 의한 확공앵커의 극한 인발력 (Ultimate Pullout Capacity of Underreamed Anchors Using Electric Discharge in weathered soil)

  • 김성규;김낙경;김재원;강병철;김태훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1354-1359
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The anchor is an underreamed anchor by using high voltage electric discharge energy. In this study, a series of field test were carried out in order to find ultimate load of underreamed anchors in weathered soil at the new apartment construction site located in Inchon, Korea. Data were analyzed in order to define a relation between ultimate load and the number of electric discharge.

  • PDF

영향인자를 고려한 연직배수재의 통수능 평가 (Estimation on Discharge Capacity of Prefabricated Vortical Drains Considering Influence Factors)

  • 신은철;박정준;김종인
    • 한국지반공학회논문집
    • /
    • 제21권9호
    • /
    • pp.13-23
    • /
    • 2005
  • 연직배수공법은 연약지반과 준설매립지반의 압밀을 촉진시키고, 강도를 증진시키는데 가장 널리 사용되는 공법중의 하나이다. 토목섬유로 제작된 연직배수재(PVD)를 활용하여 지지력이 부족한 지반을 개량하는 경우, 배수재의 통수능력이 매우 중요한 요인으로 작용한다. 일반적으로 통수능력 실험은 고무 멤브레인으로 구속압력을 가하여 행해지고 있으나, 이는 현장에서 발생할 수 있는 여러 통수능력 저하 영향인자를 충분히 반영하지 못하고 있는 실정이다. 현장조건에서 연직배수재는 해성점토나 실트질 사질토에 의해서 구속되어 배수재가 휘어지거나, 접히거나 하여 배수성능이 저하되기 때문이다. 따라서, 본 연구에서는 연직배수재를 활용하여 연약지반을 개량할 경우 현장조건을 고려한 통수능력을 평가하기 위하여 소형 통수능력 실험장치와 대형 통수능력 실험장치를 이용하여 배수재, 토사종류 및 측압, 상재하중, 동수경사의 실험조건을 설정하여, 연직배수재의 종방향 통수능력 실험을 수행하였다. 분석 결과, 배수재 종류에 따른 통수능력은 포켓식 배수재가 접착식에 비하여 크게 도출되었다. 토사종류에 따른 통수능력은 점토보다 준설토지반에서 더 크며, 하중과 동수경사, 가압시간의 증가에 따라 통수능력이 감소하는 것으로 나타났다. 포켓식 배수재가 점토지반에 타입되었을 경우, 하모니카형 코어를 가진 배수재가 요철형보다 통수능력이 크며, 준설토 지반에 타입된 경우에는 초기 배수면적비와 통수능력비가 거의 비례하는 것으로 나타났다.

순간방전 시험에 의한 산업용 축전지 잔존수명 분석 (Analysis of Industrial Battery lifetime Using Instantaneous Discharge Test)

  • 김종민;방선배;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.123-124
    • /
    • 2008
  • Battery is one of the emergency power. Battery reliability is a very important to keep up the minimum of building capabilities in case of interruption of electric power. Instantaneous discharge test is carried out for measuring transient voltage change(${\Delta}V$) and internal instantaneous impedance(Z), and then it is compared with discharge test results for the estimating the battery capacity. As a result, it was confirmed that the voltage change(${\Delta}V$) and the instantaneous impedance of the batteries failed in actual discharge test were higher that those of the sound batteries. Such an instantaneous discharge test can be a diagnosis of battery sound.

  • PDF

휴대전자기기용 저용량 리튬이온 배터리의 충방전 열화 기구 분석 및 모니터링 (Evaluation and monitoring of degradation mechanism of Li-ion battery for portable electronic device)

  • 변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권2호
    • /
    • pp.129-140
    • /
    • 2013
  • As a fundamental experimental study for reliability improvement of lithium ion secondary battery, degradation mechanism was investigated by microscopic observation and acoustic emission monitoring. Microstructural observation of the decomposed battery after cycle test revealed mechanical and chemical damages such as interface delamination, microcrack of the electrodes, and solid electrolyte interphase (SEI). Acoustic emission (AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Observed damages were attributed to sources of the detected AE signals.

실내실험과 현장실험을 통한 다양한 PVD의 연약지반개량효과 (Laboratory Test and Field Study of Soft Ground Improvement Effect by Using Various PVDs)

  • 신은철;쟌나라 나자로바
    • 한국지반신소재학회논문집
    • /
    • 제7권2호
    • /
    • pp.15-21
    • /
    • 2008
  • 인공연직배수재는 일반적인 샌드드래인에 비하여 비용 절감, 지반 교란의 최소화, 시공성 및, 시공 중에 발생될 수 있는 배수재의 변형을 최소화하는 유연성을 지니고 있다. 본 연구에서는 실내실험을 통하여 측압과 동수경사에 따른 여러형태 PVD의 통수능을 도출하였다. 시험결과는 압밀된 점토에 대한 과압력이 증가하였으며, 또한 PVD 공시체의 측압도 증가하였다. 이는 측압이 증가함에 따라 통수능이 감소됨을 나타내고 있으며, PVD 코어의 공극크기는 통수능과 비례관계에 있음을 보여준다. 현장조건을 고려하여 시뮬레이션을 통한 침하량에 대한 수치해석을 수행한 결과 현장계측한 침하량과 유사하게 나타났다.

  • PDF

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

Ni-MH 2차 전기 전극용 Zr-Ti-V-Ni-Mn계 수소저장합금의 조성에 따른 전기화학적 특성 (The electrochemical properties of Zr-Ti-V-Ni-Mn hydrogen storage alloys with various compositions for an electrode of Ni-MH secondary battery)

  • 최승준;정소이;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.219-224
    • /
    • 1999
  • Effects of alloy modification for the $Zr_{0.7}Ti_{0.3}V_{0.4}Ni_{1.2}Mn_{0.4}$ alloy as an electrode materials have been investigated. When Ti in the alloy was partially substituted by Zr, the hydrogen storage capacity and subsequently the discharge capacity increased significantly, however, the activation characteristic and rate capability decreased. By substituting Mn with other elements (Cr, Co and Fe) in the alloy, discharge capacity decreased but the cycle life and rate capability were improved. Considering both the discharge capacity, the high rate discharge property and cycle life, the $Zr_{0.7}Ti_{0.3}V_{0.4}Ni_{1.2}Mn_{0.3}Cr_{0.1}$ alloy among the alloys subjected to the test was found to be a prominent alloy for a practical usage.

  • PDF

주택용 BESS에 적용하기 위한 재활용 셀의 성능에 관한 연구 (A Study on the Performance of Recycled Cells for application to Residential BESS)

  • 김필중;양성수
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.14-19
    • /
    • 2024
  • 주택용 BESS에 적용하기 위한 재활용 셀 성능을 파악하기 위해 지난 5년 동안 사용한 셀을 선택하였다. 시험에 사용된 셀의 기본 사양은 공칭 전압이 3.7[V], 공칭 용량이 2,200[mAh], 충전 전압이 4.05[V], 연속방전전류가 1[C](2,200[mA]), 연속충전전류가 0.5[C](1,100[mA]) 이다. 새 셀의 경우 내부저항은 21.3±1[mΩ]인데, 재활용 셀의 경우 평균 내부저항이 25.38[mΩ]로 나타나 약 19.1[%] 상승하였다. 충·방전 용량은 새 셀에 비해 약 18.9~19.3[%] 정도 낮게 나타났다. 내부저항과 충·방전 용량이 셀의 노화에 상호 밀접하게 연관되어 있으므로 BESS에 적용할 셀은 초기 내부저항보다 1.5배 이하이고 70[%] 이상의 충·방전 용량 성능을 갖는 제품을 사용할 필요가 있다.