• 제목/요약/키워드: Discharge Properties

검색결과 1,332건 처리시간 0.031초

수력발전기 고정자 권선의 운전중 부분방전 특성 (Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings)

  • 김병한;김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.

액체 He중 고분자 film의 연면 및 부분방전 연구 (Surface flashover discharge and partial discharge of polymer film in liquid helium)

  • 김상현;김현희;정순용;최효상
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권9호
    • /
    • pp.942-948
    • /
    • 1996
  • Electrical properties such as surface flashover discharge and discharge degradations of insulating materials for superconducting cable have been investigated. It is found that the surface voltage is proportional to $l^{0.7}$ (l: discharge length) in liquid helium (LHe). V-t characteristic in LHe was a n=5.5 that was less than liquid nitrogen (L $N_{2}$). After applied AC voltage, the surface condition of polymer films was observed non-eroded areas and eroded areas. The eroded area is depending on the applied voltage. In case of LHe, the crack was observed.d.

  • PDF

양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성 (On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings)

  • 김희동;주영호;윤대헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성 (Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer)

  • 김희동;이상길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성 (Properties of Partial Discharge accompanying with Electrical Tree in LDPE)

  • 이광우;박영국;강성화;장동욱;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF

저압 방전등 교류 접등 특성의 이론적 예측 (Theoretical Prediction of AC Characteristics of Low Pressure Lamps)

  • 지철근;장우진;여인선;이진우
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.470-476
    • /
    • 1989
  • In order to develop a mathematical model which can predict the operating voltage and current of a discharge lamp, the properties and the physical phenomena of a low pressure gas discharge are investigated. Fluorescent lamp which uses a low pressure mercury-argon gas discharge is used in the model development. In a low pressure mercur-argon gas discharge, the continuity equation for each excited atom and electron, and the electron energy balance equation can predict the physical quantities of discharge. By coupling these equations and the circuit equation, the electrical characteristics of the discharge lamp can be predicted. To verify the validity of the suggested model, we calculated the voltage and current of a fluorescent lamp operating with inductor ballast for source frequency of 5KHz, 8KHz, 10KHz, and 13KHz. The results show good agreements in wave forms between the measured voltage and current, and the difference between the measured and calculated one is less than 5%.

  • PDF

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

기계적 혼합과 고상법에 의해 합성한 LiNi1-yGayO2의 전기화학적 특성 (Electrochemical Properties of LiNi1-yGayO2 Synthesized by Milling and Solid-State Reaction Method)

  • 김훈욱;윤순도;이재천;박혜령;박찬기;송명엽
    • 한국세라믹학회지
    • /
    • 제42권9호
    • /
    • pp.631-636
    • /
    • 2005
  • $LiNi_{1-y}Ga_yO_2$ (y = 0.005, 0.010, 0.025, 0.050, and 0.100) were synthesized by the solid-state reaction method after mechanical mixing, and their_electrochemical properties were investigated. All the $LiNi_{1-y}Ga_yO_2$ (y=0.005, 0.010, 0.025, 0.050, and 0.100) samples had the R3m structure. The sample with y = 0.025 showed the largest first discharge capacity (131.4 mAh/g) and good cycling performance [discharge capacity 117.5 mAh/g ($89.4{\%}$ of the first discharge capacity) at the 20th cycle]. The first discharge capacity decreased as the value of y increased. The samples with y = 0.010 and y = 0.005 had small R-factor but their cycling performance was worse than that of the sample with y = 0.025. All the $LiNi_{1-y}Ga_yO_2$ samples had smaller discharge capacities than $LiNiO_2$, but their cycling performances were better than that of $LiNiO_2$.

자장여과아크소스의 자장필터 꺾임 각도와 아크방전전류에 따라 증착된 ta-C 코팅의 마모 거동 연구 (A Study on the Wear Behavior of Tetrahedral Amorphous Carbon Coatings Based on Bending Angles of the Filtered Cathodic Vacuum Arc with Different Arc Discharge Currents)

  • 김원석;김송길;장영준;김종국
    • Tribology and Lubricants
    • /
    • 제38권3호
    • /
    • pp.101-108
    • /
    • 2022
  • The structure and properties of tetrahedral amorphous carbon (ta-C) coatings depend on the main process parameters and bending angles of the magnetic field filter used in the filtered cathodic vacuum arc (FCVA). During the process, it is possible to effectively control the plasma flux of carbon ions incident on the substrate by controlling the arc discharge current, thereby influencing the mechanical properties of the coating film. Furthermore, we can control the size and amount of large particles mixed during carbon film formation while conforming with the bending angle of the mechanical filter mounted on the FCVA; therefore, it also influences the mechanical properties. In this study, we consider tribological characteristics for filtered bending angles of 45° and 90° as a function of arc discharge currents of 60 and 100 A, respectively. Experiment results indicate that the frictional behavior of the ta-C coating film is independent of the bending angle of the filter. However, its sliding wear behavior significantly changes according to the bending angle of the FCVA filter, unlike the effect of the discharge current. Further, upon changing the bending angle from 45° to 90°, abrasive wear gets accelerated, thereby changing the size and mixing amount of macro particles inside the coating film.