• Title/Summary/Keyword: Discharge Load Density

Search Result 32, Processing Time 0.024 seconds

A Study for the Selection Method of Control Area of Nonpoint Pollution Source (비점오염원 관리지역의 선정 기법에 관한 연구)

  • Park, Sanghyun;Jeong, Woohyeok;Yi, Sangjin;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Determination of Focused Control Pollutant Source by Analysis of Pollutant Delivery Characteristics in Unit Watershed Upper Paldang Lake (팔당호 상류의 단위유역별 오염물질 유출특성 분석을 통한 중점관리 오염원 선정)

  • Kim, Dong Woo;Jang, Mi Jeong;Han, Ihn Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.367-377
    • /
    • 2014
  • Paldang lake which is the most important water resource in Korea is classified as a stream type reservoir and water quality of Paldang lake can be significantly influenced by external pollutant source. So this study was aimed to determine focused control BOD and TP sources of each unit watershed upper Paldang lake through analysis of pollutant source distribution and pollutant runoff characteristics. Generated load, discharge load, delivery load and each load density of 11 unit watersheds upper Paldang lake were calculated using data of water quality and flow rate from pollutant sources and 74 small streams. As a result of generated load, discharge load and delivery load of BOD and TP from pollutant sources, the most BOD generated load was taken by livestock with 66% of total BOD discharge load and domestic had the most BOD discharge load, 42.7%. The ratio of delivery load of livestock and domestic was 36.4% and 34.3%, respectively. Livestock occupied high ratio of TP generated load, discharge load and delivery load with 82.5%, 44.4% and 46.7%, respectively. Gyeongan watershed which had high population density showed the highest BOD delivery load density of $14.6kg/km^2/d$ and the highest TP delivery load density with $1.23kg/km^2/d$ was analyzed in Cheongmi watershed including the biggest number of livestock. From these results, management of domestic sewer and livestock excrement was determined as a focused control pollutant source. And intensive management about domestic sewer in Gyeongan stream and livestock excrement in Cheongmi stream is required for water quality improvement of Paldang lake.

Characterization on the Pollution Discharge Load at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin (수질오염총량관리 단위유역별 오염물질 배출부하량 특성분석 - 금강수계를 대상으로)

  • Park, Jun Dae;Choi, Ok Youn;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.786-795
    • /
    • 2012
  • Water quality management should be focused on the pollution concentrated area so that the improvement of water quality can be achieved effectively for the management of Total Maximum Daily Loads (TMDLs). It is necessary to consider discharge characteristics in the TMDL plan. This study analysed discharge characteristics such as pollution generation and discharge load density, and reduction potential by each unit watershed, and categorized the unit watershed into four groups according to its discharge load characteristics. This analysis can be used as helpful information for the prioritization of pollution reduction area and selection of pollution reduction measures in the development of TMDL plans.

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

A Study on the Spatial Strength and Cluster Analysis at the Unit Watershed for the Management of Total Maximum Daily Loads (다변량통계분석을 이용한 수질오염총량관리 단위유역별 오염물질 배출특성 분석 - 한강수계를 중심으로 -)

  • Choi, Ok Youn;Kim, Ki Hoon;Han, Ihn Sup
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.700-714
    • /
    • 2015
  • The characteristic of the water quality and pollutant discharge was analyzed at the units watershed of the total amount management in Han-river basin, and after classified in a similar area by multivariate statistical analysis, the main trend such as the water quality trend and pollutant discharge characteristic were analyzed. As a result of this study, the density of the pollutant at the unit watershed is not necessarily identified as discharge density, and the primary management watershed and targeted substances were analyzed depending on the operating status of the environmental infrastructure in watershed and the main pollution factor and discharge path per pollutants. As a result of cluster analysis, watersheds were classified into four groups according to discharge characteristics. It will be used when selecting target area of primary management that is appropriate to the characteristics of each river and establishing efficient water quality improvement plans.

Watershed Management Plan through Water Quality Monitoring for Main Branches of 4 Water Systems in Chungcheongnamdo (충청남도 4대수계 주요 지류하천 수질 모니터링을 통한 유역 관리 방안)

  • Park, Sanghyun;Kim, Hongsu;Cho, Byunguk;Moon, Eunho;Choi, Jinha
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.163-172
    • /
    • 2016
  • This study aimed to develop a plan for effective performance of a watershed through correct identification of a river watershed by using the flowrate of the river and water quality data, which is the basis for the establishment of the water environment policy. The target river for water quality improvement was selected based on the monitoring result for 4 water systems in Chungcheongnamdo province in the recent 3 years. The result of analysis for the distribution of discharge capacity by a pollution source group for the water quality improvement target river showed that most of the target river has a high discharge capacity in the water system for living and livestock. Analysis for the density of the total discharge capacity of the whole watershed of Chungcheongnamdo indicated that the river that needs water quality improvement has high BOD concentration and high discharge load density at the point that this river is located. Thus, for efficient watershed management through selection and concentration, Chungcheongnamdo needs to improve the target river in priority. Stepwise planning is also required to establish and execute the water quality improvement in order to satisfy said target water quality, and establish the index for the water improvement rate for its evaluation.

Numerical analysis of deposition and channel change in the vegetation zone (식생대에서 유사의 퇴적과 하도변화 수치모의 분석)

  • Hwang, Hyo;Jang, Chang-Lae;Kang, Minseok
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • This study analyzed the bed load transport and channel change on the vegetation zone through laboratory experiments and numerical simulations. To examine the effect of vegetation zone in the laboratory experiment, artificial vegetation zones made of acrylic sticks were installed in the experimental channel, and discharge conditions were adjusted to examine the bed load transport and channel change in the vegetation zone. Next, numerical simulations were performed by applying the same conditions as those of the laboratory experiment to the Nays2D model, a two-dimensional numerical model, and the applicability of the numerical model was examined by comparing the results with the results of the laboratory experiment. Finally, by applying a numerical model, the bed load transport and channel change according to the change in vegetation density were examined. As a result of examining the bed load transport and channel change in the vegetation zone according to the discharge condition change by applying the laboratory experiment and the numerical model, the results of the two application methods were similar. As the discharge increased, bed load from the upper stream was deposited inside the vegetation zone. On the other hand, on the other side of the vegetation zone, the flow was concentrated and erosion occurred. Also, the range of erosion increased in the downstream direction. As a result of examining the bed load transport and channel change according to the change in vegetation density, as the vegetation density increased, the bed load from the upper stream was deposited inside the vegetation zone. On the other hand, due to the increase in vegetation density, the flow was concentrated to the opposite side of the vegetation zone, erosion occurred.

Application of Priority Order Selection Technique for Water Quality Improvment in Stream Watershed by Relationship of Flow and Water Quality (유량-수질관계 비교를 통한 하천 수질개선 우선순위 선정기법 적용)

  • Lim, Bong-Su;Cho, Byung-Wook;Kim, Young-Il;Kim, Do-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.802-808
    • /
    • 2010
  • This study was carried out to apply the method of priority order selection for water quality improvement of watershed. The monitoring of flow and water quality, grouping branch streams and discharge load density were estimated on 18 branch streams located in middle and lower area of Geum River, Chungcheongnam-do. Based on average BOD concentration of stream at low flow, the results of the water quality analysis of stream which excess river living standard class 2 (less than BOD 3 mg/L) are Jeongancheon, Bangchukcheon, Gilsancheon, Jocheon, Seokseongcheon and Ganggyeongcheon. As a result of grouping stream, stream that have more than $10\;m^3/min$ of flow and more than 3.0 mg/L of average BOD concentration such as Group A are Jocheon, Seokseongcheon, Ganggyeongcheon and Jeongancheon. In Group A, stream corresponds to over than discharge load density as of 10 BOD kg/$day{\cdot}km^2$ is Jocheon, Seokseongcheon and Ganggyeongcheon. In view of the selected results to improve water quality basin through monitoring of flow and water quality, grouping stream, and estimation of discharge load density, Jocheon in Yeongi, Seokseongcheon located on the border of Buyeo and Nonsan, Ganggyeongcheon on Nonsan such as stream basin were urgent to improve water quality.

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.