• Title/Summary/Keyword: Disaster prevention facility

Search Result 144, Processing Time 0.026 seconds

Evaluation on Geological Structures to Secure Long-term Safety of Nuclear Facility Sites (원자력시설물 부지의 장기적 안전성 확보를 위한 지질구조 평가)

  • Jin, Kwangmin;Kim, Young-Seog
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.149-166
    • /
    • 2018
  • Many large earthquakes have continuously been reported and resulted in significant human casualties and extensive damages to properties globally. The accident of Fukushima nuclear power plant in Japan was caused by a mega-tsunami, which is a secondary effect associated with the Tohoku large earthquake (M=9.0, 2011. 3. 11.). Most earthquakes occur by reactivation of pre-existing active faults. Therefore, the importance of paleoseismological study have greatly been increased. The Korean peninsula has generally been considered to be a tectonically stable region compared with neighboring countries such as Japan and Taiwan, because it is located on the margin of the Eurasian intra-continental region. However, the recent earthquakes in Gyeongju and Pohang have brought considerable insecurity on earthquake hazard. In particular, this region should be secure against earthquake, because many nuclear facilties and large industrial facilities are located in this area. However, some large earthquakes have been reported in historic documents and also several active faults have been reported in southeast Korea. This study explains the evaluation methods of geological structures on active fault, fault damage zone, the relationship between earthquake and active fault, and respect distance. This study can contribute to selection of safe locations for nuclear facilities and to earthquake hazards and disaster prevention.

Evaluation test of applicability of Compressed Air Foam fire extinguishing system for train fire at rescue station in Subsea tunnel (해저터널 구난역 열차화재시 압축공기포(Compressed Air Foam) 소화설비의 적용성 평가 실험)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.413-418
    • /
    • 2016
  • Recently, a mega project such as Korea-China or Korea-Japan undersea tunnel project has been emerged for detail discussion and the interest in undersea tunnel is on the rise. More severe damage by train fire is expected in undersea tunnel comparing to ground tunnel and thus the study on more efficient fire extinguishing system, besides existing disaster prevention design is underway. To that end, a full-scale fire tests using CAF fire extinguishing system which has been developed by modifying traditional foam fire extinguishing system for fire suppression at rescue station in timely manner were conducted over 7 times. The test was conducted after setting the rescue station in virtual tunnel with a car of KTX. As a result of using compressed air foam directly to the fire source, 30 liter of Heptane combustibles was extinguished within 1 minutes. Applicability of compressed air foam to train fire at rescue station in undersea tunnel was has been proven and further study is considered required while changing the nozzle angle and location so as to achieve quick and easy extinguishing goal, making use of the advantage of CAF, as well as to reduce the fire water and chemicals required.

Estimation on Filling Performance of Thixotropic Grout for Increasing Front-Water Depth of Gravity-Type Quay Wall (중력식 안벽 구조물의 증심 시공을 위한 가소성 그라우트의 충진성능 평가)

  • Jang, Kyong-Pil;Ryu, Yong-Sun;Kwon, Seung-Hee;Han, Woon-Woo;Oh, Myong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.169-177
    • /
    • 2017
  • Recently, as the size of transportation vessels has increased, there is a growing need for securing the front-water depths of existing port facilities. The method of deepening front-water depth is securing the depth of the port facility, and it is reinforced by grouting after excavating the rubble-mound to the required depth. The purpose of this study is to investigate the reinforcing performance and filling performance of thixotropic grout as a grouting material for reinforcing rubble-mound. Compressive strength tests were carried out for two types of thixotropic grout, and 5 specimens with a diameter of 400 mm and a height of 530 mm were manufactured and evaluated for filling performance. The required strength of reinforced rubble-mound required to ensure the safety of the structure is 6 MPa. All the thixotropic grouts used in this study were found to satisfy the required strength over 9 MPa at 7 days of age. As a result of visual observation of filling state of the filling performance test specimens, it was confirmed that the thixotropic grout was well filled up to the desired fillet height.

Sensitivity analysis of pump and tank sizes on water network operation and water age (송수펌프용량 및 배수지규모에 따른 송·배수시스템의 운영비용 및 체류시간 분석)

  • Kim, Kangmin;Choi, Jeongwook;Jung, Donghwi;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.803-813
    • /
    • 2017
  • Recently, various studies have been conducted to optimize the pump operation scheduling and/or the pump/tank size minimizing the system cost of water distribution network. Prior to that, it is important to understand the sensitivity of pump/tank size on the system cost and overall water quality. Here, we have performed the sensitivity analysis to investigate the effect of pump/tank size on the economic cost (construction and operation) and water quality (water age). The analysis was applied on a real, large-scale water transmission network currently operating in South Korea. The results revealed that the pump/tank size has a strong influence on system construction/operation costs. Especially, the tank size has a significant effect on the system-wide water quality. In the case of applied networks, the operating cost decreases as the capacity of the facility increases, but the design cost increases. Using a sensitivity analysis, a suitable range of pump/tank size could be suggested to minimize costs and stabilize the water quality at the same time prior to a system design.

A Study on the Management Method of Agricultural reservoir Using RCP Scenario (RCP 시나리오 분석을 통한 농업용 저수지 관리방안에 관한 연구)

  • Choo, Yeon Moon;Won, Chang Hee;Kim, Seong Ryul;Gwon, Chang Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 2020
  • A reservoir is defined as an artificial facility that stores and controls water during floods and droughts. Korea has constructed and managed reservoirs all over the country to benefit farming communities. The importance of reservoirs has decreased gradually due to urbanization and the spread of tap water, but the importance of water is increasing because of the recent shortage of water and the resulting rise in the price of water resources. Therefore, this study suggests countermeasures through an analysis of the used threshold for agricultural reservoirs. To this end, the forecast of rainfall up to 2100 was first analyzed using flood estimates and RCP scenarios through rainwater data collection. The increase in the RCP 8.5 scenario, the largest increase in the probability rainfall, was calculated by adding it to the current probability rainfall, and it was predicted that the marginal height of Odong Dam would reach its limit in 2028. Therefore, as a countermeasure against this, the measures to secure effective water storage were suggested through measures, such as lowering the height of Yeosu and installing movable beams. Overall, it is expected that effective management of the reservoirs used for agriculture will be possible in the future.

Estimation of the Kinetic Energy of Raindrops for Hourly Rainfall Considering the Rainfall Particle Distribution (강우입자분포를 고려한 시강우의 강우에너지 산정 연구)

  • Kim, Seongwon;Jeong, Anchul;Lee, Giha;Jung, Kwansue
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.15-23
    • /
    • 2018
  • The occurrence of soil erosions in Korea is mostly driven by flowing water which has a close relationship with rainfalls. The soil eroded by rainfalls flows into and deposits in the river and it polluted the water resources and making the rivers become difficult to be managed. Recently, the frequency of heavy rainfall events that are more than 30 mm/hr has been increasing in Korea due to the influence of climate change, which creating a favourable condition for the occurrence of soil erosion within a short time. In this study, we proposed a method to estimate the distribution of rainfall intensity and to calculate the energy produced by a single rainfall event using the cumulative distribution function that take into account of the physical characteristics of rainfall. The raindrops kinetic energy estimated by the proposed method are compared with the measured data from the previous studies and it is noticed that the raindrops kinetic energy estimated by the rainfall intensity variation is very similar to the results concluded from the previous studies. In order to develop an equation for estimating rainfall kinetic energy, rainfall particle size data measured at a rainfall intensity of 0.254~152.4 mm/hr were used. The rainfall kinetic energy estimated by applying the cumulative distribution function tended to increase in the form of a power function in the relation of rainfall intensity. Based on the equation obtained from this relationship, the rainfall kinetic energy of 1~80 mm/hr rainfall intensity was estimated to be $0.03{\sim}48.26Jm^{-2}mm^{-1}$. Based on the relationship between rainfall intensity and rainfall energy, rainfall kinetic energy equation is proposed as a power function form and it is expected that it can be used in the design of short-term operated facility such as the sizing of sedimentation basin that requires prediction of soil loss by a single rainfall event.

The Study on the Fire Monitoring Dystem for Full-scale Surveillance and Video Tracking (전방위 감시와 영상추적이 가능한 화재감시시스템에 관한 연구)

  • Baek, Dong-hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2018
  • The omnidirectional surveillance camera uses the object detection algorithm to level the object by unit so that broadband surveillance can be performed using a fisheye lens and then, it was a field experiment with a system composed of an omnidirectional surveillance camera and a tracking (PTZ) camera. The omnidirectional surveillance camera accurately detects the moving object, displays the squarely, and tracks it in close cooperation with the tracking camera. In the field test of flame detection and temperature of the sensing camera, when the flame is detected during the auto scan, the detection camera stops and the temperature is displayed by moving the corresponding spot part to the central part of the screen. It is also possible to measure the distance of the flame from the distance of 1.5 km, which exceeds the standard of calorific value of 1 km 2,340 kcal. In the performance test of detecting the flame along the distance, it is possible to be 1.5 km in width exceeding $56cm{\times}90cm$ at a distance of 1km, and so it is also adaptable to forest fire. The system is expected to be very useful for safety such as prevention of intrinsic or surrounding fire and intrusion monitoring if it is installed in a petroleum gas storage facility or a storing place for oil in the future.

A Study on the Development of Universal Design Evaluation System in the Public Space (공공공간의 유니버설디자인 평가체계 개발 연구)

  • Park, Cheongho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.2
    • /
    • pp.25-37
    • /
    • 2021
  • Purpose: The main purpose of this study is to develop an evaluation system using the weighted-values of various users and experts for the public space to apply Universal Design, and additionally to find out the commonalities and differences by comparing the importance of evaluation indicators between users and expert groups. Method: A one-sample t-test was conducted to verify that the components of the public space to universal design application are suitable as evaluation indicators, and AHP(analytic hierarchy process) was performed to derive weight-values for the evaluation system. Results: The importance-values for the total 23 facilities to be used as evaluation indicators were derived by multiplying the weighted-values of each sector, domain, and facility by the disabled, non-disabled, and experts. To summarize the results of overall importance-values derived from the AHP, The disabled showed high-rank weighted-values in facilities of building sector > park & recreation sector > cross domain and low-rank weighted-values for sidewalk and roadway domain. The non-disabled showed high-rank weighted-values in facilities of park & recreation sector > roadway domain > building sector > cross domain and low-rank weighted-values for sidewalk domain. Experts mainly showed high-rank weighted-values in the cross domain and in facilities related to entry and movement to the target space in all sectors and domains. However, it showed moderate importance-values in the sanitary space. The disabled who are restricted to movement have a high demand for universal design in buildings consisting of vertical moving line, and non-disabled people who are not limited to physical movement have a high demand for universal design in parks and recreation sector for increased leisure time. It means that experts are important to recognize the principles of making space because they value cross domain and the key spaces and facilities for suitable the purpose of use. In addition, it can be inferred that non-disabled people have a higher demand for safety than disabled people due to their high importance in roadway domain and facilities of safety and disaster prevention. Implications: The significance of this study is the establishment of a quantitative universal design evaluation system for public spaces considering the different perspectives of the disabled and the non-disabled.

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.