• Title/Summary/Keyword: Direction measurement

Search Result 1,590, Processing Time 0.036 seconds

Development of a New On-line fiber Orientation Sensor Based on Dielectric Anisotropy

  • Nagata, Shinichi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.5
    • /
    • pp.49-55
    • /
    • 2002
  • A new method is proposed for the on-line measurement of the fiber orientation of sheet materials. The measurement of fiber orientation is very important in manufacturing paper sheets, non-woven fabrics, and glass sheets, because fiber orientation strongly affects product properties represented by, for example, dimensional stability of paper. A method developed in this research utilizes anisotropy of dielectric constants of sheet materials as a key characteristic to determine the fiber orientation. The new on-line sensor, consisting of 5 microwave dielectric resonators set in different directions, was designed to detect the fiber orientation while paper is running with high speed on a paper machine. This sensor can determine the direction and the degree of fiber orientation from the measured direction of the maximal dielectric constant and its variation, respectively. The fundamental performance of this system was examined by the static measurement of printing grade paper, which gave a satisfactory result. Then, the dynamic measurements were done at a speed of 1,000 m/min by using a high-speed test-coating machine.

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

An analysis on the Earth geoid surface variation effect for use of the tilt sensor in celestial navigation system

  • Suk, Byong-Suk;Yoon, Jae-Cheol;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1867-1870
    • /
    • 2005
  • The celestial navigation is one of alternatives to GPS system and can be used as a backup of GPS. In the celestial navigation system using more than two star trackers, the vehicle's ground position can be solved based on the star trackers' attitude information if the vehicle's local vertical or horizontal angle is given. In order to determine accurate ground position of flight vehicle, the high accurate local vertical angle measurement is one of the most important factors for navigation performance. In this paper, the Earth geophysical deflection was analyzed in the assumption of using the modern electrolyte tilt sensor as a local vertical sensor for celestial navigation system. According to the tilt sensor principle, the sensor measures the tilt angle from gravity direction which depends on the Earth geoid surface at a given position. In order to determine the local vertical angle from tilt sensor measurement, the relationship between the direction of gravity and the direction of the Earth center should be analyzed. Using a precision orbit determination software which includes the JGM-3 Earth geoid model, the direction of the Earth center and the direction of gravity are extracted and analyzed. Appling vector inner product and cross product to the both extracted vectors, the magnitude and phase of deflection angle between the direction of gravity and the direction of the Earth center are achieved successfully. And the result shows that the angle differences vary as a function of latitude and altitude. The maximum 0.094$^{circ}$angle difference occurs at 45$^{circ}$latitude in case of 1000 Km altitude condition.

  • PDF

The Effect of Fatigue on EMG Activity and Dynamic Balance of Subjects with Functional Lumbar Instability

  • Kim, Myong-Chul;Kim, Ho-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.207-213
    • /
    • 2015
  • Purpose: The aim of the current study was to investigate EMG activity on dynamic balance of subjects with functional lumbar instability following fatigue of low back. Methods: The subjects (24 university students) were divided into 2 groups; functional lumbar instability group (6 males and 6 females) and lumbar stable group (7 males and 5 females) who could complete a questionnaire and undergo a prone instability test. All participants were evaluated for distribution of muscle activity using the TeleMyo DTSTM system. Dynamic balance was tested by Y balance test. This study was conducted for measurement of EMG activity on dynamic balance with the difference between FLIG and control group following muscle fatigue. Results: The functional lumbar instability group (FLIG) showed a significantly lower YBT score (%) of anterior, posterolateral direction on Y-balance test (YBT) in dynamic balance than the lumbar stable group (LSG) (p<0.05). The FLIG was significantly lower than the LSG in anterior direction in EMG activity(%) of MF, RA, ES, GMX, GME, RF, and posteromedial direction in EMG activity(%) of IO, ES and then posterolateral direction in EMG activity(%) of IO, ES in dynamic balance (p<0.05). There was significant correlation of MF, RA, and GMX in anterior reach direction (p<0.05) and ES, GME (p<0.01) and IO, ES in posteromedial reach direction (p<0.05) and EO, ES, GMX in posterolateral reach direction (p<0.05) there was positive correlation. Conclusion: This study showed that FLIG effected EMG activity by dynamic balance following muscle fatigue. Further study is needed for measurement of various ages and work with lumbar instability for clinical application.

A New Speed Measurement Circuit Using 2 Way Edge Detection Method (2중천이검출방식을 이용한 새로운 속도 측정회로)

  • Yoon, Kyung-Sup;Lee, Moo-Young;Kim, Woo-Hyun;Kwon, Woo-Hyen
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.280-289
    • /
    • 1997
  • The measure of motor speed using encoder is difficult to detect accurate speed and direction in very low speed because the intervals between an encoder pulse and pulse are long. So various speed estimation techniques were proposed to have the good dynamic performance in low speed. And direction detection is so important as speed measurement in very low speed. But because the conventional direction detection circuit check the direction only 1 time in 1 period of each encoder pulses, so it has long delayed detection time in very low speed, thus accurate detection of direction is difficult. In this paper, we propose a 2 way edge detection method which can detect at the rising and filling edge of each encoder pulses. So it can check the direction 4 times in 1 period of each encoder pulses. Therefore if we use proposed method, we can reduce the detection time as 1/4 than that of conventional circuit and can detect more accurate speed and direction. And computer simulation and experiment is performed to verify the perfomance and effect of proposed circuit and we analyze it's results by comparing with that of conventional circuit.

  • PDF

Double-Excitation Type Single Sheet Tester for the Measurement of the Magnetic Characteristics of the Electrical Steel Sheets (전기강판의 자기특성 측정을 위한 2방향 여자 형 Single Sheet tester 개발)

  • Kim, Hong Jung;Koh, Chang Seop;Hong, Sun-Ki;Shin, Pan Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.10
    • /
    • pp.461-469
    • /
    • 2005
  • In this paper, a double-excitation type single sheet tester is developed to measure the magnetic characteristics of the electrical steel sheets. The developed system has the uniform magnetic field area of 20$\times$20mm$^{2}$, and can be applied to the measurement of the magnetic characteristics of the Non-oriented and Grain oriented electrical steel sheets. In the developed system, the magnetic flux density and magnetic field intensity are measured by using B-coil and H-coil, respectively. The B-coil has 1 turn search coil for each direction, and H-coil has 640 and 640 turns for rolling direction and transverse direction on the Im thickness Glass-Epoxy basement, respectively. Through experiments, it Is shown that the system can measure the magnetic characteristics up to 1.87 of magnetic flux density in the rolling direction in case of the Grain oriented electrical steel sheet. The measured results are compared with those measured in Okayama university, .Japan.

Bone Density Spatial Distribution of Radiation Dose Measurement (양방사선 골밀도 측정 장치의 공간산란선량분포측정)

  • Kim, Seon-Chil;Won, Do-Yeon;Park, Chang-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • In this experiment, how DEXA(Dual-energy X-ray Absorptiometry) bone mineral density was measured using the equipment. In order to maintain the same measurement conditions, bone mineral density measurements of 10 cm thick phantom, with an actual patient at a point when examining the same conditions(100 kVp, 1 mA) and then out to the five doses of radiation and its average was calculated by dividing measured. X-ray dose rate measured at the Research Institute, Sword of the gamma survey meters calibrated MEDCOM Ltd. (Inspector GM counter tube) was used, calibration factor is 1.15. On a horizontal plane around the patient, depending on the distance was significantly reduced dose rate. In addition, orientation $0^{\circ}$ head end was higher in the direction of the highest dose rate, $0^{\circ}$ $180^{\circ}$ direction from the direction towards the higher dose rate reduced to some extent in the direction of all the $120^{\circ}$ were able to identify.

  • PDF

Classification of Fall Direction Before Impact Using Machine Learning Based on IMU Raw Signals (IMU 원신호 기반의 기계학습을 통한 충격전 낙상방향 분류)

  • Lee, Hyeon Bin;Lee, Chang June;Lee, Jung Keun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.96-101
    • /
    • 2022
  • As the elderly population gradually increases, the risk of fatal fall accidents among the elderly is increasing. One way to cope with a fall accident is to determine the fall direction before impact using a wearable inertial measurement unit (IMU). In this context, a previous study proposed a method of classifying fall directions using a support vector machine with sensor velocity, acceleration, and tilt angle as input parameters. However, in this method, the IMU signals are processed through several processes, including a Kalman filter and the integration of acceleration, which involves a large amount of computation and error factors. Therefore, this paper proposes a machine learning-based method that classifies the fall direction before impact using IMU raw signals rather than processed data. In this study, we investigated the effects of the following two factors on the classification performance: (1) the usage of processed/raw signals and (2) the selection of machine learning techniques. First, as a result of comparing the processed/raw signals, the difference in sensitivities between the two methods was within 5%, indicating an equivalent level of classification performance. Second, as a result of comparing six machine learning techniques, K-nearest neighbor and naive Bayes exhibited excellent performance with a sensitivity of 86.0% and 84.1%, respectively.

Measurement of the Fiber Orientation Distribution for Thickness direction of Injection Molded Long Fiber Reinforced Polymeric Composites (장섬유강화 플라스틱 복합재의 사출성형에 있어서 두께방향의 섬유배향 분포측정)

  • 윤성운;박진국;조선형;김이곤
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1998.03a
    • /
    • pp.199-204
    • /
    • 1998
  • In this study, a method is presented which can be used to measure the fiber orientation distribution for thickness direction during injection molding using image processing. The intensity method in used for measuring the distribution. And the effects of fiber content, injection molding condictions on the orientation function are also discussed.

  • PDF

The evaluation of thermal parameter for quench characteristics in Bi-2223/Ag superconducting system (Bi-2223/Ag 초전도시스템의 퀜치특성을 위한 열적 파라미터 평가)

  • Choi, S.;Nah, W.;Jang, S.H.;Joo, J.;Ha, H.S.;Sohn, M.H.;Kwon, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1237-1239
    • /
    • 2005
  • In this study, we estimate the thermal conductivity of stainless steel reinforced Bi-2223/Ag tape which was made from American Superconductor. The equipments for thermal conductivity measurement was set up using conduction cooled cryocooler. Two direction of thermal conductivity was measured. The one is the direction of cut length, and the other is direction of transverse of wounded coil with insulation material. It was observed that the thermal conductivity of transverse direction of coil was extremely lower than that of cut length direction. It was mainly seems that superconducting filaments and insulation material were effected on thermal conductivity in thermal conductivity of transverse direction.

  • PDF