Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

The Study of Body Types of Adult Women in Korea (한국 20대 성인여성의 체형 연구)

  • 손희순;손희정
    • The Research Journal of the Costume Culture
    • /
    • v.6 no.2
    • /
    • pp.141-152
    • /
    • 1998
  • In the result of classification body types for 100 adult women by direct measurements and antropometric measurements, the mean of weight is bigger than he mean of weight of 97'. So modern 20's women is more than than 94'. In the result of factor analysis, 5 factors were extracted (horizontal sizes, vertical sizes, and degree of shoulder) from exponent sizes of the antropometric measurements item, and another 5 factors were extracted (thick of body, horizontal form of the torso, silhouette of the torso, and size of abdomen) from direct measurements item. The body types are classified into 4 types by cluster analysis in the result of direct measurement item, and another body types are classified into 5 types by antropometric measurement item, it was classified into the horizontal size and the shape and silhouette of torso, and by direct measurement item, it was only classified into the vertical and horizontal size. So for the patternmaking of clothing, it is more adoptable the classification of body by antropometric measurement item than direct measurement item.

  • PDF

Proposal of Nail Tip Size by Measuring Nail Size of Korean Women in Their 20s -Focusing on Size Comparison Through Direct Measurement and 3D Scanner Measurement- (20대 국내여성의 손톱 사이즈 측정을 통한 네일 팁 사이즈 제안 -직접측정법과 3D 스캐너측정법을 통한 사이즈 비교를 중심으로-)

  • Lee, Eunsil;Kim, Eunsil
    • Journal of Fashion Business
    • /
    • v.24 no.1
    • /
    • pp.102-116
    • /
    • 2020
  • After its introduction in Korea, nail art is becoming active, especially among women in their 20s and 30s who are interested in fashion and beauty. Although self-nail tips are available online in various designs for each brand that is currently on the market, these designs and sizes of self-nail tips on the market are different for each age group. Since the design or size is not suggested for the different situations, there are difficulties in purchasing products that match the shape and size of nails of consumers. In this study, frequency analysis was performed using 'SPSS statistics 21.0 for windows program' to analyze data obtained by direct measurement method and 3D scanner measurement method for Korean women in their 20s. For comparative analysis between direct and 3D scanner measurements, a corresponding sample, 'T-test', was performed. As a result, we proposed the standardization of nail tip size after comparative analysis between direct measurement and 3D scanner measurement. Previous studies have been proceeding with direct measurement method. However, this study introduced a 3D scanner measurement method in the nail field and attempted the standardization of nail size by age group of Korean women. Importantly, this sutdy suggests standardization of nail tip size among missing body sizes.

Analysis of Difference between Direct Measurement and 3-D Automatic Measurement According to Classification of Side Figure of Elderly Women (고령 여성의 측면체형 분류에 따른 직접측정치와 3차원 자동측정치간의 차이 분석)

  • Chung, Juwon;Nam, Yun-Ja;Park, Jinhee
    • Fashion & Textile Research Journal
    • /
    • v.21 no.5
    • /
    • pp.627-639
    • /
    • 2019
  • This study analyzes differences between the results of 3D direct measurements and automated measurements for Korean elderly females according to age groups, side somatotype, and BMI groups. This study compares the measurement differences of the direct and the 3D automated measurements for women between the ages of 70 to 85, according to age group, BMI group, and side somatotype. A comparison of the results of the direct measurement and the 3D automated measurements for elderly women show that a meaningful discrepancy exists for 29 items out of 33 items. Furthermore, the results of comparing the average error tolerance recommended by ISO20685 shows that 30 items out of 33 items exceeded ISO recommendations. The results of the automated measurement program shows a higher degree of accuracy for straight postures; however, this unsuitable for postures of elderly women with a changed somatotype. The analysis results of the measurement difference indicate the suitability of the automatic measurement programs is found to be high for stood postures, while problems seem to exist on several items along with an automated program is not appropriately used due to posture and part of body changes for elderly women. Therefore, it is recommended to develop an algorithm, that reflects the body changes of elderly women first and then upgrade the automated program equipped with a measurement size method. It is hoped that the study results can be utilized as base data for improving the automated measurement program.

Disagreement between direct and indirect blood pressure measurements obtained from minipigs

  • Lee, Won-Jae;Park, Lisa Soyeon
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.131-136
    • /
    • 2018
  • Blood pressure (BP) measurement plays a pivotal role in veterinary medicine for diagnosing cardiovascular disorders and monitoring anesthesia of animals. Although indirect BP measurement has been widely applied to monitor BP because of its convenience and non-invasiveness, it is still unclear whether indirect BP measurement is compatible with direct BP measurement in minipigs. In addition, the effect of animal posture during BP measurement is not well understood in minipigs despite its importance to cardiovascular performance. Therefore, both systolic and diastolic arterial BPs in minipigs were measured via femoral artery catheterization for direct BP measurement and using a compressive cuff as an indirect BP measurement under the dorsal or right lateral recumbent postures. Numerical values were processed by the Bland-Altman method to calculate the bias ${\pm}$ SD and the limits of agreement (LOA). In accordance with the American College of Veterinary Internal Medicine guidelines, the results between direct and indirect BP measurements were determined as apparent disagreements in both systolic and diastolic arterial BPs under all postures because of large bias ${\pm}$ SD and wide LOA. The results of the present will help prevent misinterpretation of the anesthetized patient's condition during monitoring of BP by indirect measurement.

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

A System for Measuring 3D Human Bodies Using the Multiple 2D Images (다중 2D 영상을 이용한 3D 인체 계측 시스템)

  • 김창우;최창석;김효숙;강인애;전준현
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

Development of the Photogrammetric Method of Head Through 3-Dimensional Approach (3차원적 접근 방식을 통한 머리 부위 사진 측정법의 개발)

  • Kim, Woong;Nam, Yun-Ja;Kim, Min-Hyo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.7-13
    • /
    • 2005
  • We developed an accurate and reliable photogrammetric method available instead of the direct measurement method and the three-dimensional scanning method. Our research was restricted to a head on the body. Approaching three-dimensionally, we calibrated a distorted image of a photograph and got linear equations of camera beams. Then we assigned z values of landmarks in the head and obtained three-dimensional coordinates for each landmark putting those z values in linear equations of camera beams and finally could calculate measurement results from those three-dimensional coordinates. When we compared results obtained by a program, 'Venus Face Measurement(VFM)' that we had developed applying our method with results obtained by the direct measurement method, VFM showed very accurate and reliable results. In conclusion the photogrammetric method developed in this study was testified to an outstanding measurement method as a substitute for the direct measurement method and the three-dimensional scanning method.

Representative Male Upper Body types of the 20s by the Combination of Direct and Indirect Measurement Values (직접측정치(直接測定値)와 간접측정치(間接測定値)의 결합(調合)에 의한 20대(代) 남성(男性) 상방신(上半身) 대표체형(代表體型) 연구( 硏究))

  • Li, Eun-Ji;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.4
    • /
    • pp.135-151
    • /
    • 2007
  • This study is human body measurement of 200 adult males in their 20s by both direct and indirect methods in order to reveal the representative male upper body types. Composition factors of body types were classified while the combination of direct-indirect measurement values was chosen. The following are the findings: 1) The analysis of direct-indirect measurement statistics showed the following results: 173.80cm (height), 69.87kg (weight), 95.58cm (chest girth), $24.67^{\circ}$ (right shoulder angle), and $9.34^{\circ}$ (shoulder width angle). 2) The factor analysis of the body types by direct measurement produced 5 factors: 1 (front length of upper body), 2 (front length of upper body), 3 (back length of upper body), 4 (circumference of upper body), and 5 (shoulders length). These factors accounted for 90.08%. Also, the cluster analysis of factor scores led to 3 types: 1 (33%, short, comparatively wide shoulders and full in the hips), 2 (25.1%, well-developed upper body in tall, inversed triangle), 3 (41%, average height, short upper body). 3) The body-type factor analysis by indirect measurement resulted in 6 factors with the explanation of 83.24%: 1 (rear upper bady thickness), 2 (front upper body width), 3 (front chest thickness), 4 (left-right shoulder angle), 5 (front width of protrusion distance in chest and shoulders), and 6 (neck's front-rear side angle).In addition, the cluster analysis of factor scores brought about 4 types: 1 (15%, well-developed front chest, beardless waist), 2 (23.5%, flat chest, with shoulder, drooping shoulders, strait neck), 3 (39%, with shoulder, curved back), and 4 (22.5%, narrow and thin, curved waist). 4) Among the 118 subjects (75%), 58 subjects commonly appearing in indirect measurement values group and direct measurement values group were chosen the representative body type group according to asterisk indexes. They had the highest frequency in direct type 3 and indirect type 3, whose combination represented the physical characteristics of the representative body types.