• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.028 seconds

A Novel High-Performance Strategy for A Sensorless AC Motor Drive

  • Lee, Dong-Hee;Kwon, Young-Ahn
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.81-89
    • /
    • 2002
  • The sensorless AC motor drive is a popular topic of study due to the cost and reliability of speed and position sensors. Most sensorless algorithms are based on the mathematical modeling of motors including electrical variables such as phase current and voltage. Therefore, the accuracy of such variables largely affects the performance of the sensorless AC motor drive. However, the output voltage of the SVPWM-VSI, which is widely used in sensorless AC motor drives, has considerable errors. In particular, the SVPWM-VSI is error-prone in the low speed range because the constant DC link voltage causes poor resolution in a low output voltage command and the output voltage is distorted due to dead time and voltage drop. This paper investigates a novel high-performance strategy for overcoming these problems in a sensorless ac motor drive. In this paper, a variation of the DC link voltage and a direct compensation for dead time and voltage drop are proposed. The variable DC link voltage leads to an improved resolution of the inverter output voltage, especially in the motor's low speed range. The direct compensation for dead time and voltage drop directly calculates the duration of the switching voltage vector without the modification of the reference voltage and needs no additional circuits. In addition, the proposed strategy reduces a current ripple, which deteriorates the accuracy of a monitored current and causes torque ripple and additional loss. Simulation and experimentation have been performed to verify the proposed strategy.

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

The Economic Burden of Cancers Attributable to Metabolic Syndrome in Korea

  • Kim, Dongwoo;Yoon, Seok-Jun;Gong, Young-Hoon;Kim, Young Ae;Seo, Hye-Young;Yoon, Jihyun;Kim, A-Rim
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.4
    • /
    • pp.180-187
    • /
    • 2015
  • Objectives: Metabolic syndrome is an important etiologic factor in the development of certain types of cancers. The economic cost of the treatment of cancer has been steadily increasing. We therefore estimated the economic burden of cancers attributable to metabolic syndrome in Korea. Methods: We reviewed metabolic syndrome-related cancers and relative risk and then calculated population attributable fractions. We analyzed insurance claims data for metabolic syndrome-related cancers in 2012 in order to estimate the direct costs associated with these cancers, including hospitalization, outpatient visits, transportation costs, and caregivers' costs as well as indirect costs such as loss of productivity due to cancer treatment and premature death. Results: In 2012, 18 070 patients in Korea had cancers attributable to metabolic syndrome. The economic burden was USD 199.8 million and the direct and indirect costs were USD 124.5 million and USD 75.3 million, respectively. Conclusions: We estimated the economic burden of cancers attributable to metabolic syndrome in Korea and the efforts are necessary to reduce this burden.

A Study on the Noise Reduction of a Portable Fuel Cell System (휴대용 연료전지 시스템의 소음 저감에 대한 연구)

  • Jeon, In-Youl;Bae, Joon-Soo;Oh, Min-Jung;Choi, Sang-Hyeon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF

Synthesis and Thermal Properties of Poly(benzoxazole)s Based on Pendants

  • Jang, Hyewon;Lee, Seulbi;Choi, Jae Kon
    • Elastomers and Composites
    • /
    • v.50 no.2
    • /
    • pp.138-145
    • /
    • 2015
  • A series of wholly aromatic poly(hydroxyamide)s(PHAs), containing varying amounts of 2,6-dimethylphenoxy group and quinoxaline ring in the main chain, were synthesized by a direct polycondensation method. The inherent viscosities of the PHAs in either DMAc or DMAc/LiCl solution at $35^{\circ}C$ were found to be in the range of 1.02~1.90 dL/g. In the solubility study, we observed that PHA 1, PHA 2, and PHA 3 were dissolved in aprotic solvents such as DMAc, NMP, DMF, and DMSO with LiCl on heating; however, PHA 4, PHA 5, and PHA 6 could be dissolved in aprotic solvents on heating without LiCl. For poly(benzoxazole)s(PBOs), the 10% and maximum weight loss temperatures were in the range of $582{\sim}622^{\circ}C$ and $630{\sim}659^{\circ}C$, respectively. Residues of PBOs at $900^{\circ}C$ were found to be relatively high, which were in the range of 65.3~70.8%.

Circular Fresnel POF(Plastic Optical Fiber) Daylighting System Performance Evaluation Study (원형 프레넬 집광형 POF 주광 조명시스템 성능 평가 연구)

  • Kang, Eun-Chul;Choi, Yong-Jun;Yoon, Kwang-Sik;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • CF(Circular Fresnel) POF(Plastic Optical Fiber) daylighting system is a beam daylighting system utilizing solar direct beam radiation. In this study, a CF POF daylighting system has been introduced, developed and applied to KIER test buildings. The CF POF daylighting system consists of three parts: light collector, light transmitter and light diffuser. The light collector includes a Circular Fresnel lens focusing solar direct illuminance by sun tracking. The light transmitter contains the POF cable which has light transmission loss of 4.5% per meter. The light diffuser has about 80% diffuser efficiency. This study aims to evaluate of POF daylighting system performance. At the results of a CFPOF system performance evaluation, the theoretical CFPOF system efficiency was 41.9% and the actual CFPOF system efficiency at the KIER test building was 37.5%. The difference was due partly to the connecting efficiency.

A Study on the Regional Property for the Agricultural Water Demand (농업용수 수요량의 지역적 특성 조사 연구(관개배수 \circled1))

  • 김선주;이광야;여운식;박재흥
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.120-125
    • /
    • 2000
  • This study analyzes agricultural water demand nationwide which calculated by the estimation system for agricultural water demand(ESAD) with the data are observed in the other Studies. The results are as follows. Maximum, minimum and average values of annual evapotranspiration in paddy in 1,767 boundaries covering all the country are estimated as 819.2mm, 595.2mm and 702.9mm respectively. In the case of transplant seeding, the annual effective rainfall is estimated as 834.7mm to 464.3mm, while the average is 635.3mm. The amount of effective rainfall is largest in case of transplant seedlings and then come watered direct seeding and dry direct seeding regardless of region. Maximum, minimum and average values of annual evapotranspiration in upland in 1,767 boundaries are estimated as 659.97mm, 129.3mm and 411.8mm respectively. The annual effective rainfall is estimated as 607.2mm to 68.3mm while the average is 257.4mm. infiltration ratio in paddy in 1,767 boundaries applied in ESAD is 5.06mm/day in average, varying from 12.0mm/day to 2.0mm/day. Applied conveyance loss is 12.8% in average, varying from 18.0% to 8.0%.

  • PDF

A Study on Earned Value Management System (EVMS) For Project Using ERP System (ERP 시스템을 이용한 프로젝트 EVMS에 관한 연구)

  • Park, Je-Won;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.145-151
    • /
    • 2010
  • It seems that a primary concern of the project-based company, which provides a large scale product or service over long term period, is to run a successful project through systematic project process control and control costs. One of the typical project control methods is Earned Value Management System(EVMS) which analyses the precess through performance measurement. Even though the EVMS is a highly efficient tool in the managerial aspect, it cannot easily determine the Planned Value(PV), Actual Cost(AC), or Earned Value(EV) due to the indistinct criteria and extensive data. The accurate calculation of AC in particular, is the basic of project management, but most companies record direct personnel expenses or direct expenses only. Since they calculate indirect expenses based on the estimated ratio, it limits the systematic project management that reflects changes in profit and loss of a company. This study introduces a EVMS for project management and its actual case based on EVMS and ERP system which some additional modules are installed for performance measurement. It is expected that this new method enables a company to save time and effort, and also to improve transparency by specifying expense items in detail and to switch quarterly settlement to monthly by reducing the time of calculation.

The Change of Hair Surface According to Perm Treatment Method (퍼머 시술방법에 따른 모발표면의 변화)

  • Kim, Jung-Hae;Yoo, Tae-Soon;Jung, Youn
    • Fashion & Textile Research Journal
    • /
    • v.9 no.3
    • /
    • pp.341-346
    • /
    • 2007
  • This research is the hair damage as treating a perm before and after that is compared the change of surface characteristics of human hair. On the basis of this, we would to show a basic data for hair damage prevention and hair improvement to keep the beautiful and healthy hair. Results are as follows; For the change of formational characteristics of hair surface, untreated hair before the perm treatment had smooth appearance overall and undamaged scale that is in pattern and finely folded was observed but damaged hair and extremely hair had uneven edge and damages throughout along with the dissolution of scale which the border of epidermal gap is unclear. Hair after a perm treatment caused cortical exposures due to extensive loss of scale during the treatment and even bubble effect. Protein perm, regular perm, soft perm, and direct heating perm, in that order, had the most damages to the hair.

Cost Estimation of Accidents in Auto-Glass Manufacturing Process (자동차유리 제조공정에서 발생하는 산업재해의 손실비용 추정)

  • Lim, Hyeon-Kyo;Lee, Seung-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.43-48
    • /
    • 2011
  • Estimation of accident costs would set a sound criterion on which invest judgement for work improvement would be decided. Unfortunately, however, the professional agency and most companies in Korea still adopt the conventional cost estimation method based on Heinrich's theory would not be applicable any more since it was developed about a century ago. This research was carried out to confirm the validity of conventional accident cost estimation method. With 110 accident cases occurred in an autoglass manufacturing plant for last 7 years, post-accident treatment procedure was simplified as a model with several phases, and practical costs were analyzed case by case. The results showed that, as expected, the company should the largest portion of loss due to accidents, and that mean indirect cost were 10.10(${\pm}20.70$) times as much as direct cost estimated by conventional method. Therefore, finally, accident types and items influenced much on accidents costs were analyzed and discussed.