• Title/Summary/Keyword: Direct Loss

Search Result 907, Processing Time 0.03 seconds

The Converter of High Efficiency 48V 400A for Electronic Exchange (전자교환기용 고효율 48V 400A급 전력변환장치의 시작)

  • 박성우;서기영;전중함;김부국;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.60-63
    • /
    • 1998
  • The widely used power supply (Switched Mode Power Supply : SMPS) as a source in order to stabilize direct current for electronics or communication systems has merits, when it is compared to the existing source for stability, such as high efficiency, small size, light weight by means of switching process of the semiconductor device which controls the flow of power. However, due to existence of inductors and capacitors used for charging energy, the source part in electronic or communication systems hasn't reached the speed, that is supposed to get, for achieving smaller size and lighter weight. In order to get smallness in size, it is necessary to increase switching frequency. And that makes devices for measuring energy smaller. Nevertheless, the rise switching frequency brings increases in switching loss, inductor loss, and power loss. Also, the occurrence of surge and noise caused by high frequency switching is getting higher. The resonant converter has been considered as one of methods that give solutions for the problems of SMPS and that method have been paid attention as a source technology in electronics and communication.

  • PDF

Correlation Between the Optical Performance of the Reflective Polarizer and the Structure of LCD Backlight

  • Yu, Mi-Yeon;Lee, Byung-Woo;Lee, Jeong-Ho;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.256-260
    • /
    • 2009
  • The optical performance of the reflective polarizer was investigated over three kinds of direct-lit backlights and/or different configurations of the optical sheets. The optical gain factor achieved by using the reflective polarizer increased as the diffuse nature of the optical sheet was enhanced, because of the more efficient polarization conversion. In addition, the gain factor decreased substantially in flat-lamp backlights compared to tubular-lamp backlights, which was ascribed to the high loss factor during the polarization recycling process due to the complex structure and large area of flat lamps. All these results suggested that reducing the loss factor of the backlight is very important for efficient polarization conversion and thus high optical gain of the reflective polarizer.

Current Status of the 2nd Generation of Intact Stability: Investigation of the Pure Loss of Stability and Parametric Roll Mode

  • Chung, Jaeho;Shin, Dong Min;Kim, Won-Don;Moon, Byung Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.55-65
    • /
    • 2020
  • A review of the 2nd generation of intact stability by the International Maritime Organization is performed. The main issues with the new stability criteria are reviewed. In particular, the physical background and related mathematical formulations of the pure loss of stability and parametric roll are summarized. Based on a literature review, benchmark calculation results for 17 different types of ships are discussed, and the final results are in excellent agreement with our physical expectations. Some relatively serious design problems are found in the application of the new stability criteria to sample ships built in Korea, and possible technical solutions are proposed, which have to be improved in the coming years.

Optimal Control Scheme for Matrix Converter (매트릭스컨버터의 최적제어기법 고찰)

  • Cho, Choon-Ho;Mo, Dong-Yeong;Lee, Sang-Chul;Choi, Chang-Young;Lee, Gun-Sik;Kim, Tae-Woong;Park, Gwi-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.21-22
    • /
    • 2010
  • Matrix converter is direct power conversion system. Matrix converter has many merits that possible bidirectional power flow, input power factor own control and system without DC-link. But matrix converter has some demerits that need many switching devices and switching loss. This paper suggest optimal matrix converter control scheme for improvement for switching loss part. Proposed control scheme verified that 10% improvement in efficiency, input current's harmonic loss and output voltage's EMI improvement.

  • PDF

A Study on the Non-Insurance Cost due to the Industrial Accident - On the focus of the Ulsan area cooperation - (산업재해로 인한 비보험비용에 관한 연구 - 울산지역의 중소기업을 대상으로 -)

  • 고성석;이태영
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.103-109
    • /
    • 2001
  • When workers get accidents in doing their works, industrial accident insurance covers the compensation for the accidents. Generally, this kind of costs is applied in terms of Direct Cost. In our society circumstance to terminate the accident, many kinds of cost (Non-Insurance Cost) are also discharged. Non-Insurance Cost resulted from additional compensation for insurance allowance, is the important basic data source to estimate Loss Cost. Several studies have been done for the output of accident cost, but companies have difficult to apply these studies into practice and generalize the amount of accident loss cost. This study means to suggest improving solutions for the output of Accident Loss Cost and to reduce Opportunity Cost caused by Industrial Accident.

  • PDF

Development of An Integrated Controller for a Direct Drive Turbo Compressor (직접 구동방식 터보 압축기를 위한 통합 제어기 개발)

  • 권정혁;변지섭;최중경
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.4
    • /
    • pp.225-234
    • /
    • 2003
  • Turbo compressors need high speed rotating impeller in structure, high rate gearbox and conventional induction motor. This mechanical system increased moment of inertia and mechanical friction loss. Recently turbo compressor has adopted a super high-speed motor and driver and have made its size smaller and mechanical friction loss at minimum. In this paper, variable super high - speed motor controller, compressor controller and MMI controller are implemented with only one DSP (TMS320VC33) chip for a 150HP, 70,000rpm direct drive turbo compressor. It was required hardware and software integration. The result of integration, Controller hardware became simple and all control software are developed same developing tool. The implements turbo compressor meets the requirements.

Network Analysis on Ageing Problems : Identifying Network Differences between Types of Cities

  • Seo, Bojun;Lee, Soochang
    • International Journal of Advanced Culture Technology
    • /
    • v.5 no.2
    • /
    • pp.19-25
    • /
    • 2017
  • The research is to identify social networks of problems that have an influence on the quality of ageing people's lives by using social network analysis, based on the premise that there are differences in networks of ageing problems in urban and rural areas. From analyzing network of ageing people's problems using NodeXL, vertices in the networks of both urban and rural areas are well-connected. For urban areas, financial poverty is the core problem related to the quality of life. It has direct connections with illness and health, family responsibility, housing, role loss in community, and employment, which have positive or negative interactions with the quality of older people's lives. For rural areas, on the other hand, role loss in community is the major problem. It has direct connections with the elderly abuse, financial poverty, leisure activity, divorce, isolation and loneliness from society, education, and suicide. As a result, the research shows that the problems of ageing people have strong linkages and interactive effects with a structure of network, and the networks are different depending on types of places for living.

Radio Coverage Prediction of DMO Terminal in TETRA TRS (TETRA TRS에서 DMO 단말기의 전파도달범위 예측)

  • Lee, Soon-Hwa;Kim, Chang-Bock
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.51-56
    • /
    • 2014
  • TETRA(TErrestrial Trunked RAdio) provide specialized disaster radio communication services as a standard European for digital TRS(Trunked Radio System). Especially, DMO(Direct Mode Operation) feature is used effectively in the radio shadow areas which base station does not propagate radio signal because it can communicate directly with terminal to terminal without base station's relay function. However, to effectively used DMO feature, radio coverage prediction information should be provided to users. Therefore in this paper, we were calculated link budget of TETRA DMO terminals which were distributing and operating in the country and then predicted reaching distance about radio propagation to be applied with path loss model.

A Study of minimization of Playback Loss Time on IP-TV Platform based on TIT (TIT 기반에 IP-TV 플랫폼의 재생 소실 시간 최소화에 관한 연구)

  • Sso, Sang-Jin;Jin, Hyun-Joon;Park, Noh-Kyung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2007
  • Since the DirectTV started its digital broadcasting services in 1994 for the first time in the U.S., digital broadcasting widened its services in many areas. In korea, TIT(Transport Information Technology) based IP-TV services have been provided in Saemaeul trains and some sections of subway trains. But the software systems for the service performed in alternated fashions and suffered from many problems such as suspension, memory leaking and overflow. These problems increased playback loss time and resulted in bad reliabilities. In this paper, a software TIT monitor is designed and implemented for the TIT system in physically poor environments. The designed system formalized monitoring time intervals for effective monitoring. Through the real experiments, playback time is improved in 14% comparing to existing system.

  • PDF

The Development of Super High Speed PMSM Sensorless Vector driver for Direct Drive Method Turbo Compressor (직접 구동방식의 터보 압축기를 위한 초고속 영구자석형 동기전동기 센서리스 벡터 구동 시스템 구현)

  • 권정혁;변지섭;최중경;류한성
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.879-884
    • /
    • 2002
  • There are screw, reciprocating and turbo compressor by structure in an air compressor, essential equipment on he industrial spot. Resently it is wide that the range of turbo compressor's use in gradual, turbo compressor needs high speed rotation of impeller in structure, high rated gearbox and conventional induction motor. This mechanical system increased the moment of inertia and mechanical friction loss. Resently the study of turbo compressor applied super high speed motor and drive, removing gearbox made its size small and mechanical friction loss minimum. In this study we tried to develope variable super high speed motor drive systems for 150Hp, 70,000rpm drect drive Turbo compressor. The result of study is applied to a 150Hp direct turbo compressor and makes it goods.