• 제목/요약/키워드: Direct Diffusion

검색결과 293건 처리시간 0.029초

A SIMPLE CHARACTERIZATION OF POSITIVITY PRESERVING SEMI-LINEAR PARABOLIC SYSTEMS

  • Haraux, Alain
    • 대한수학회지
    • /
    • 제54권6호
    • /
    • pp.1817-1828
    • /
    • 2017
  • We give a simple and direct proof of the characterization of positivity preserving semi-flows for ordinary differential systems. The same method provides an abstract result on a class of evolution systems containing reaction-diffusion systems in a bounded domain of ${\mathbb{R}}^n$ with either Neumann or Dirichlet homogeneous boundary conditions. The conditions are exactly the same with or without diffusion. A similar approach gives the optimal result for invariant rectangles in the case of Neumann conditions.

3D 적층 IC를 위한 웨이퍼 레벨 본딩 기술 (Wafer Level Bonding Technology for 3D Stacked IC)

  • 조영학;김사라은경;김성동
    • 마이크로전자및패키징학회지
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2013
  • 3D 적층 IC 개발을 위한 본딩 기술의 현황에 대해 알아보았다. 실리콘 웨이퍼를 본딩하여 적층한 후 배선 공정을 진행하는 wafer direct bonding 기술보다는 배선 및 금속 범프를 먼저 형성한 후 금속 본딩을 통해 웨이퍼를 적층하는 공정이 주로 연구되고 있다. 일반적인 Cu 열압착 본딩 방식은 높은 온도와 압력을 필요로 하기 때문에 공정온도와 압력을 낮추기 위한 연구가 많이 진행되고 있으며, 그 가운데서 Ar 빔을 조사하여 표면을 활성화 시키는 SAB 방식과 실리콘 산화층과 Cu를 동시에 본딩하는 DBI 방식이 큰 주목을 받고 있다. 국내에서는 Cu 열압착 방식을 이용한 웨이퍼 레벨 적층 기술이 현재 개발 중에 있다.

수동급기 직접 메탄올 연료전지의 동적 모델 (Dynamic Model of a Passive Air-Breathing Direct Methanol Fuel Cell)

  • 하승범;장익황;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • The transient behavior of a passive air breathing direct methanol fuel cell (DMFC) operated on vapor-feeding mode is studied in this paper. It generally takes 30 minutes after starting for the cell response to come to its steady-state and the response is sometimes unstable. A mathematical dynamic one-dimensional model for simulating transient response of the DMFC is presented. In this model a DMFC is decomposed into its subsystems using lumped model and divided into five layers, namely the anodic diffusion layer, the anodic catalyst layer, the proton exchange membrane (PEM), the cathodic catalyst layer and the cathodic diffusion layer. All layers are considered to have finite thickness, and within every one of them a set of differential-algebraic governing equations are given to represent multi-components mass balance, such as methanol, water, oxygen and carbon dioxide, charge balance, the electrochemical reaction and mass transport phenomena. A one-dimensional, isothermal and mass transport model is developed that captures the coupling between water generation and transport, oxygen consumption and natural convection. The single cell is supplied by pure methanol vapor from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The water is not supplied from external source because the cell uses the water created at the cathode using water back diffusion through nafion membrane. As a result of simulation strong effects of water transport were found out. The model analysis provides several conclusions. The performance drop after peak point is caused by insufficiency of water at the anode. The excess water at the cathode makes performance recovery impossible. The undesired crossover of the reactant methanol through the PEM causes overpotential at the cathode and limits the feeding methanol concentration.

  • PDF

인터넷을 이용한 DLC(Direct Load Control)의 구성 및 부하제어기법 (A Configuration of DLC(Direct Load Control) Using Internet Communication and Load Control Method)

  • 이재경;김인수;김형중;이승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.60-64
    • /
    • 2001
  • Recent recovery of the Korean economy drives a rapid increase in utility consumption and requires more stable utility supply and maintenance. However, power location security hardship, reinforcement of international environmental regulation and a huge cost of power plant construction have increased the burden laid on the stable supply. In addition, an efficient and flexible load management is required more than any era since an increment of the rate of increase in cooling load is expected. Therefore, according as the necessity of direct load control for cooling load during the summer in Korea was on the rise, direct load control systems by Internet communication method are constructed at five commercial buildings. Based on practical load control, this study proposes various application modes and communication methods prior to extension diffusion of direct load control hereafter.

  • PDF

직접메탄올연료전지에서 메탄올 크로스오버에 미치는 인자 연구 (Investigation of Factors Influencing Methanol Crossover in Direct Methanol Fuel Cell)

  • 현민수;김상경;임성엽;이병록;백동현;정두환
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 2008
  • 직접메탄올연료전지의 운전 변수에 따른 메탄올 크로스오버를 메탄올 농도센서를 이용하여 정량적으로 측정하였으며 실제 셀 운전 시 메탄올크로스오버 저감의 측면에서 유리한 운전조건을 분석하였다. 메탄올 농도, 전극 양단의 압력차, 전류의 크기, 온도, stoichiometry등을 변화시켜 diffusion, convection, electro-osmosis의 메커니즘별 기여도와 실제 전지 운전 조건의 영향을 함께 분석하였다. 이상의 세 가지 메커니즘 중에서 농도 차이에 의한 diffusion이 가장 큰 영향을 미쳤으며 electro-osmosis에 의한 영향은 고농도에서만 관찰할 수 있었다.

$Hg_{1-x}Cd_xTe$ OMVPE System 과 ARIIV Reactor Chamber의 설계 및 제작 (Disign of $Hg_{1-x}Cd_xTe$ OMVPE System and ARIIV Reactor Chamber)

  • 한석룡
    • 한국진공학회지
    • /
    • 제2권4호
    • /
    • pp.410-415
    • /
    • 1993
  • The direct growth OMVPE system, designed specificallyfor direct growth of Hg1-xCdxTe using annular rectant inlet inverted verticla (ARIIV) reactor, was constructed. This paper presents the detailed technical approach on a newly designed ARIIV reactor that increases Hg incorporation, imposes uniformity, and avoids the needs for temperature processing to create alloys by inter diffusion approach.

  • PDF

DIRECT PROBING OF CARRIER MOTION IN ORGANIC FIELD EFFECT TRANSISTOR BY OPTICAL SECOND HARMONIC GENERATION

  • Iwamoto, Mitsumasa;Manaka, Takaaki;Lim, Eun-Ju
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1561-1563
    • /
    • 2008
  • We report an optical second harmonic generation measurement that allows direct probing of dynamical carrier motion in organic field effect transistors. Carrier injection and transport process are discriminated. The mobility and contact resistance of pentacene FETs are determined from the visualized diffusion-like carrier motion.

  • PDF

와동과 상호작용하는 화염편에서의 오염물질 생성특성 (Pollutant Formation Characteristics in a Flamelet Interacting with a Vortex)

  • 오창보;이의주
    • 한국안전학회지
    • /
    • 제25권1호
    • /
    • pp.9-16
    • /
    • 2010
  • Flame structure of diffusion flame interacting with a single vortex was investigated with direct numerical simulation (DNS). A well-known counterflow diffusion flame was used as an initial flat flame and single vortices were made by issuing a high-velocity jet abruptly in fuel- and air-side. The variations in the maximum concentration of major species (CO and $CO_2$) and NOx (NO and $NO_2$) with the stoichiometric scalar dissipation rate were investigated. Unsteady effects in the species concentration variation of the flame interacting with a vortex were identified by comparing with that of steady flame. $NO_2$ formation characteristics of the flame interacting with a vortex were well understood by investigating the $HO_2$ formation. To enhance the prediction performance in the fire simulation, current turbulent combustion modelings are needed to be modified by adopting the unsteady effects in the species concentrations of diffusion flame interacting with a vortex.