• Title/Summary/Keyword: Direct Detection

Search Result 926, Processing Time 0.028 seconds

Analysis of array receivers for use in optical communication (광 통신에 이용되는 배열 수신기의 해석)

  • Sung, Pyung-Shik
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.3
    • /
    • pp.173-180
    • /
    • 2007
  • This paper describes the point-detector arrays system to processes the fields of signal and noise of the turbulent atmosphere. By using aboves, the maxmum output of direct-detection shows a little differences between experimental datas and theoretical datas. As a whole the experimental datas are agreed with the joint Gaussian theoretical curves and K-distribution curves.

  • PDF

Communications with a Brain-wave bio-potential based computer interface

  • Choi, Kyoung-Ho;Minoru, Sasaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.46.3-46
    • /
    • 2001
  • The overall aim of this research is to develop a computer communication interface based on brain-wave bio potentials for physically disabled people. The work focuses on using EOG and EMG signals to input characters one by one using cursor movements on a GUI screen. The Cyberlink TM system is used to acquire brain waves in real time with electrodes. EMG and EOG signals are used to direct a cursor in order to select, or to click on a character on the screen. We present a novel method for automatic EOG pattern detection by using wavelet transforms with a neuro-fuzzy approach ...

  • PDF

LIGO-India: Beyond discovery of Gravitational waves.

  • Souradeep, Tarun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.27.2-27.2
    • /
    • 2017
  • The historic discovery of gravitational waves through direct detection by the LIGO observatories in the USA, in principle, opens up a new window for astronomy. In practice, however, the true launch of gravitational-wave astronomy will await the global array of LIGO like observatories including the planned LIGO-India observatory recently flagged off by the Union cabinet of India. I will review the momentous discovery, the potential of gravitational-wave astronomy and the promise of LIGO-India.

  • PDF

Direct Solid Sample Analysis in the Moderate Power He Mip with the Spark Generation

  • S. R. Koirtyohann;Yong-Nam Pak
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.8
    • /
    • pp.622-627
    • /
    • 1994
  • Conducting solid samples are successfully analyzed with the spark ablation combined to the moderate power (500W) Helium Microwave Induced Plasma (He MIP). The relative standard deviations are in the range of 3-10% and the detection limits are around 50 ${\mu}$g $g^-1$. These values are higher than those of Ar MIP or Ar Inductively Coupled Plasma. Spark ablated particles are examined to investigate the analytical characteristics of the system.

Determination of meloxicam in human plasma by semi-micro high-performance liqiud chromatography.

  • Park, Chang-Hun;Kim, Ho-Hyun;Lee, Hee-Joo;Beom, Han-Sang
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.276.1-276.1
    • /
    • 2003
  • This study describes a simple and sensitive semi-micro HPLC method with UV detection and direct deproteinization. The plasma protein was precipitated using perchloric acid (60%) and the supernatant was directly injected onto the semi-micro HPLC system. The separation was achieved on a C18 (25 mm ${\times}$ 2.0 mm I.D) analytical column with a mobile phase of sodium acetate buffer (pH 3.5, 50 mmol) - acetonitrile (60:40, V/V). (omitted)

  • PDF

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

A Hybrid Multiuser Detection Algorithm for Outer Space DS-UWB Ad-hoc Network with Strong Narrowband Interference

  • Yin, Zhendong;Kuang, Yunsheng;Sun, Hongjian;Wu, Zhilu;Tang, Wenyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.5
    • /
    • pp.1316-1332
    • /
    • 2012
  • Formation flying is an important technology that enables high cost-effective organization of outer space aircrafts. The ad-hoc wireless network based on direct-sequence ultra-wideband (DS-UWB) techniques is seen as an effective means of establishing wireless communication links between aircrafts. In this paper, based on the theory of matched filter and error bits correction, a hybrid detection algorithm is proposed for realizing multiuser detection (MUD) when the DS-UWB technique is used in the ad-hoc wireless network. The matched filter is used to generate a candidate code set which may contain several error bits. The error bits are then recognized and corrected by an novel error-bit corrector, which consists of two steps: code mapping and clustering. In the former step, based on the modified optimum MUD decision function, a novel mapping function is presented that maps the output candidate codes into a feature space for differentiating the right and wrong codes. In the latter step, the codes are clustered into the right and wrong sets by using the K-means clustering approach. Additionally, in order to prevent some right codes being wrongly classified, a sign judgment method is proposed that reduces the bit error rate (BER) of the system. Compared with the traditional detection approaches, e.g., matched filter, minimum mean square error (MMSE) and decorrelation receiver (DEC), the proposed algorithm can considerably improve the BER performance of the system because of its high probability of recognizing wrong codes. Simulation results show that the proposed algorithm can almost achieve the BER performance of the optimum MUD (OMD). Furthermore, compared with OMD, the proposed algorithm has lower computational complexity, and its BER performance is less sensitive to the number of users.

Specific Detection of Listeria monocytogenes in Foods by a Polymerase Chain Reaction (PCR에 의한 식품으로부터 Listeria monocytogenes의 특이적 검출)

  • Shin, Soon-Young;Koo, Young-Jo;Kim, Wang-June
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1628-1634
    • /
    • 1999
  • The polymerase chain reaction (PCR) for the sensitive and specific detection of Listeria monocytogenes was employed by using LM 1 and LM 2 primers which were based on the listeriolysin O gene. The direct use of cell suspension as DNA template, without DNA extraction or lysis step, was suitable and specific enough to detect L. monocytogenes at the level of $10^2$ CFU or less per PCR for the pure culture and milk sample, however, the detection sensitivity became blunt for other food samples such as kimchi and chicken. The nested PCR, in which L-1 and L-2 (both designed from listeriolysin O gene) were employed as inner primers, was specific for detecting L. monocytogenes and enhanced the detection limit by 10 times. The PCR using LM 1 and LM 2 primers was very effective to detect L. monocytogenes from foods in terms of the specificity and time consumed, i. e. within $4{\sim}8\;hrs$ (nested PCR).

  • PDF

Aflatoxin Residues in Agricultural Commodities Determined by Direct ELISA (ELISA에 의한 농산물중 Aflatoxin 잔류 조사)

  • 조명행;손동화;이문한
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.4
    • /
    • pp.281-287
    • /
    • 1997
  • We have reported a sensitive, specific and simple direct competitive ELISA method to detect aflatoxin in agricultural commodities. We evaluated the ELISA for practical use to detect aflatoxins contaminated in the domestic and foreign agricultural commodities. The detection limits of the direct ELISA for residual aflatoxins in rice, pine nuts, corns, almonds, bean nuts, and pistachio were 10 ppb and in peanuts and cashew nuts were 20 ppb, which were elucidated from the standard curves of ELISA for aflatoxin fortified into the agricultural commodities. Residue studies of naturally contaminated aflatoxins in the agricultural commodities were also carried out by using direct ELISA. As the results of the studies, it was revealed that there were no residues of aflatoxins in 20 rice samples produced in south Korea, 20 pine nut samples in south Korea (9 samples), USA (1 sample) and China (10 samples), each of 20 almond, pistachio and bean nut samples in USA. However, aflatoxin residues were detected in corn samples imported from north Korea (350∼585 ppb in 2 of 3 samples), from USA (109*326 ppb in 6 of 6 samples) and domestic corns (61-326 ppb in 7 of 17 samples). The toxins were contaminated in corn imported from USA for popcorn (17∼20 ppb, in 3 of 10 samples) whereas no residues were detected in corn from south Korea and China. In case of cashew nuts imported from India, 11.4∼23.1 ppb of aflatoxins were detected in 4 from 20 samples. Most of the contaminated foods were harvested before 1995. Thus, hygienic managements of the foods should be required during storage and circulation at market.

  • PDF

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF