• Title/Summary/Keyword: Dipole Distribution

Search Result 154, Processing Time 0.027 seconds

Investigation of Boundary between Pohang and Janggi Basins by Electrical Resistivity Survey (전기비저항(電氣比抵抗) 탐사(探査)에 의한 포항분지(浦項盆地)와 장기분지의 경계규명(境界糾明))

  • Min, Kyung Duck;Yun, Hyesu;Moon, Hi-Soo;Lee, Hyun Koo;Lee, Dae-Ha
    • Economic and Environmental Geology
    • /
    • v.23 no.2
    • /
    • pp.215-219
    • /
    • 1990
  • Geological and electrical resistivity surveys along the survey line of about 3 km between Kyungsangbukdo Youngilgun Hodong and Gwangmyungdong using by dipole-dipole electrode array method were carried out to examine the boundary and structural relationship between Tertiary Pohang and Janggi basins. Electrical resistivity data were interpreted qualitatively and quantitatively by means of pseudosection of apparent electrical resitivity distribution and finite difference method for two dimensional geologic structure model. The nearly vertical fault zone with low electrical resistivity value of 1-5 Ohm-m and widths of about 200m at the surface and 400 m at depth exists around 1.2 km west of national road between Ocheoneup and Yangbukmyun. Mudrocks, sandstones and tuffaceous rocks are widely distributed with electrical resistivity values of 6-77 Ohm-m. Especially, tuffaceous rocks with relatively high electrical resistivity value are predominant at eastern side of fault zone. Consequently, it is known that Pohang and Janggi basins are in fault contact.

  • PDF

Penetrated Electric Fields and Resonant Frequencies inside Metallic Enclosure with Aperture Exited by an External Dipole Source (개구를 갖는 함체의 외부 다이폴 파원에 의한 침투전계와 공진 주파수 특성)

  • 황보승;김기채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.939-947
    • /
    • 2001
  • This paper presents the penetrated electric fields and resonant frequencies inside a metallic enclosure with aperture excited by an external dipole source. In the theoretical analysis, integral equations for the current distribution and electric field distributions on the aperture are solved by applying Galerkin\`s method of moments. The results show that the electric fields inside metallic enclosure is maximum at the near the aperture and resonant frequencies are the same as calculated of the enclosure without aperture. To verify the theoretical analysis the electric field inside enclosure and resonant frequencies are compared with the experimental results.

  • PDF

염수침입 현상의 전기비저항 분석에 대한 지구통계기법의 응용

  • 심병완;정상용;김병우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.92-96
    • /
    • 2001
  • Although the problem of seawater intrusion at the coastal aquifer was recognized before over one hundred years at the coastal aquifer, much groundwater keep on being salinitized by several reasons such as groundwater exhaustion, coastalline change, and human activities. The horizontal and vertical electrical soundings and geostatistical methods were used to define the local characteristics of saltwater intrusion and to estimate the saltwater interface in the southeastern area of the Pusan City. The 24 points of the Schlumberger vertical electrical soundings(VES) to loom depth and the 2 lines of dipole-dipole horizontal soundings are peformed. The resistivity data have lognormal distributions. The horizontal extents of saline water intrusion were estimated from the inversion of horizontal prospecting data. Lognormal ordinary kriging is used in A-A' resistivity profiles on May and July because the data have stationary models in semivariograms. Lognormal IRF-k kriging is used for the isopleth maps using vertical resistivity data. The 10 ohm-m resistivity line on the isopleth maps of 21m, 30m, 50m, and 70m depth using resisitivity data measured in July is sifted to the east, cpomparing that of the isopleth maps measured in May. The kriged vertical and horizontal resistivity isopleth maps suggested that the geostatistical methods can be used to define the variation of earth resistivity distribution at the saltwater interface.

  • PDF

Development and Application of the Computer Program for the Performance and Noise Prediction of Axial Flow Fan (축류형 송풍기의 성능 및 소음 예측을 위한 전산 프로그램의 개발 및 적용)

  • Chung, Dong-Gyu;Hong, Soon-Seong;Lee, Chan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.3 s.8
    • /
    • pp.31-40
    • /
    • 2000
  • A computer program is developed for the prediction of the aerodynamic performance and the noise characteristics in the basic design step of axial flow fan. The flow field and the performance of fan are analyzed by using the streamline curvature computing scheme with total pressure loss and flow deviation models. Fan noise is assumed to be generated due to the pressure fluctuations induced by wake vortices of fan blades and to radiate via dipole distribution. The vortex-induced fluctuating pressure on blade surface is calculated by combining thin airfoil theory and the predicted flow field data. The predicted performances, sound pressure level and noise directivity patterns of fan by the present method are favorably compared with the test data of actual fan. Furthermore, the present method is shown to be very useful in optimizing design variables of fan with high efficiency and low noise level.

  • PDF

Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone (옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)-)

  • Min, Kyung Duck;Kim, Chang Ryol;Yun, Chun Sung;Chung, Seung Hwan
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF

Theoretical Analysis of Open Water Characteristics of a Rudder (타 단독 특성의 이론적 해석)

  • I.Y. Gong;C.G. Kang;C.M. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.29-42
    • /
    • 1992
  • A potential based panel method is used to predict the open water characteristics of spade-type rudders. The inflow velocity is assumed to be constant in lime and uniform in space. Source and dipole are distributed on the rudder surface. It is assumed that the wake surface is streaming from trailing edge and it is represented by dipole distribution. In this paper, wake geometry is assumed by imposing appropriate conditions at the trailing edge and far from the body. The effects of wake geometry are studied. The pressure Kutta condition is applied at the trailing edge, the effects of which are compared with those of two-dimensional Kutta condition. The results of calculations for a spade-type rudder are compared with published results. It is concluded that this approach shows fairly good agreement with experimental results and can be used in the initial design stage of a rudder.

  • PDF

Aerosol Synthesis of Gd2O3:Eu/Bi Nanophosphor for Preparation of Photofunctional Pearl Pigment as Security Material

  • Jung, Kyeong Youl;Han, Jang Hoon;Kim, Dae Sung;Choi, Byung-Ki;Kang, Wkang-Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.5
    • /
    • pp.461-472
    • /
    • 2018
  • $Gd_2O_3:Eu/Bi$ nanoparticles were synthesized via spray pyrolysis and applied for the preparation of a luminescent pearl pigment as an anti-counterfeiting material. The luminescence properties were optimized by changing the $Eu^{3+}$ and $Bi^{3+}$ concentration. Ethylene glycol was used as an organic additive to prepare the $Gd_2O_3:Eu/Bi$ nanoparticles. The highest emission intensity was achieved when the total dopant content was 10.0 at.% and the mole fraction of Bi was 0.1. The concentration quenching was mainly due to dipole-dipole interactions between the same activators, and the critical distances were 9.0 and $19.6{\AA}$ for $Eu^{3+}$ and $Bi^{3+}$, respectively. The prepared $Gd_2O_3:Eu/Bi$ powder exhibited an average size of approximately 82.5 nm and a narrow size distribution. Finally, the $Gd_2O_3:Eu/Bi$ nanophosphor coated on the surface of the pearl pigment was confirmed to have good red emission under irradiation from a portable ultraviolet light-emitting diode lamp (365 nm).

Analysis on particle deposition onto a heated, horizontal free-standing wafer with electrostatic effect (정전효과가 있는 가열 수평웨이퍼로의 입자침착에 관한 해석)

  • Yoo, Kyung-Hoon;Oh, Myung-Do;Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1284-1293
    • /
    • 1997
  • The electrostatic effect on particle deposition onto a heated, Horizontal free-standing wafer surface was investigated numerically. The deposition mechanisms considered were convection, Brownian and turbulent diffusion, sedimentation, thermophoresis and electrostatic force. The electric charge on particle needed to calculate the electrostatic migration velocity induced by the local electric field was assumed to be the Boltzmann equilibrium charge. The electrostatic forces acted upon the particle included the Coulombic, image, dielectrophoretic and dipole-dipole forces based on the assumption that the particle and wafer surface are conducting. The electric potential distribution needed to calculate the local electric field around the wafer was calculated from the Laplace equation. The averaged and local deposition velocities were obtained for a temperature difference of 0-10 K and an applied voltage of 0-1000 v.The numerical results were then compared with those of the present suggested approximate model and the available experimental data. The comparison showed relatively good agreement between them.

Calculation of Magnetic Fields under 3 Phase Power Lines with Branch Lines (분기선로가 있는 3상 전력선로하의 전자파 자계 계산)

  • Kang, Dae-Ho;Lee, Yong-Sik;Kim, Bu-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.110-119
    • /
    • 2009
  • In this study magnetic fields near electric power lines with branch lines which have a arbitrary angle were derived and formulated by dipole antenna theory and could be calculated easily using the formula. It seems that those formula could be applicable to the consideration of magnetic fields during the design of distribution lines with branch lines. As an example those formulated equations on elements of magnetic fields were applied to a model of 3 phase distribution lines with branch lines and calculated by Matlab programs and the results were presented The analyzed results are follows. The resultant magnetic field is dominated by the componant By all over y-axis in the case of the smaller branched angle $\alpha$ and the lower observed point z. In case of ${\alpha}=\frac{\pi}{2}$[rad], the resultant field is affected by the componant Bx. The resultant field is dominated by the componant Bz at the vicinity of the power lines and it shows very large value at the branch line position of y-axis in case of ${\alpha}>\frac{\pi}{2}$.

Nonlinear Inversion of Time-domain Induced Polarization Data with Negative Apparent Chargeability Data (음의 겉보기 충전성 자료를 포함한 시간영역 유도분극 자료의 비선형 역산)

  • Cho, In-Ky;Kim, Yeon-Jung
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.139-148
    • /
    • 2021
  • Negative apparent chargeability data in time-domain induced polarization (IP) survey are very often considered as noise and rejected before the inversion stage. Negative IP data can, however, occur naturally as a consequence of the distribution of chargeable zones in the ground. In some cases, the negative apparent chargeability values may account for most of the data measured. Negative IP data are caused by the geometry of chargeable zones and electrode positions. Negative apparent chargeability data appear most frequently when a dipole-dipole array is used. In this study, the effect of negative apparent chargeability data on inversion results is analyzed through the numerical 2D time-domain IP modeling and nonlinear inversion. The results demonstrate clearly that negative apparent chargeability data have to be included in the inversion as they contain important information on the distribution of subsurface chargeability.