• Title/Summary/Keyword: Dilution volume

Search Result 134, Processing Time 0.028 seconds

Development of an Auto Dilution Unit of Substrate Solutionfor a Flow Injection Type Biosensor (흐름주입식 바이오센서용 기질용액 자동희석 장치 개발)

  • Song, D.B.;Jung, H.S.;Jung, D.H.;Kim, S.T.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.443-448
    • /
    • 2006
  • For development of an on-line monitoring unit of fermentation process, an auto dilution unit based on traditional chemical and biological analytical method was developed and the performance was evaluated. The dilution unit was constructed with two syringe pumps and flow direction change valves and fully automated. Total delivery volume of two pumps using distilled water was measured to confirm the operating stability And diluted concentrations of three substrate solutions (glucose, lactic acid, ethanol) were compared with a standard method with a high performance liquid chromatograph (glucose, lactic acid) and gas chromatograph (ethanol). Relative error values of total delivery volume of the pumps were below 3% and standard deviation values were 0.003 (n=5). Relative error values of diluted concentration of the dilution unit measurements were below 2% with 1/10 of dilution ratio and 70, $80{\mu}{\ell}$ of sample volume conditions for glucose and lactic acid, 1/30 of dilution ratio and $70{\mu}{\ell}$ of sample volume conditions for ethanol, respectively. In case of the ethanol, cause of the evaporative characteristics, the relative error values showed over 5% whole experimental conditions.

Pathophysiology and management of disorders in water metabolism (수분 대사 장애 질환의 병태 생리와 치료)

  • Kim, Dong Un
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.430-435
    • /
    • 2007
  • Even though we drink and excrete water without recognition, the amount and the composition of body fluid remain constant everyday. Maintenance of a normal osmolality is under the control of water balance which is regulated by vasopressin despite sodium concentration is the dominant determinant of plasma osmolality. The increased plasma osmolality (hypernatremia) can be normalized by the concentration of urine, which is the other way of gaining free water than drinking water, while the low plasma osmolality (hyponatremia) can be normalized by the dilution of urine which is the only regulated way of free water excretion. On the other hand, volume status depends on the control of sodium balance which is regulated mainly by renin-angiotensin-aldosterone system, through which volume depletion can be restored by enhancing sodium retention and concomitant water reabsorption. This review focuses on the urine concentration and dilution mechanism mediated by vasopressin and the associated disorders; diabetes insipidus and syndrome of inappropriate antidiuretic hormone secretion.

Effect of Hydrogen Dilution Ratio and Crystallinity of nc-Si:H Thin Film on Realizing High Mobility TFTs (고이동도 TFTs 구현에 nc-Si:H 박막의 수소 희석비와 결정성이 미치는 영향)

  • Choi, Jiwon;Kim, Taeyong;Pham, Duy phong;Jo, Jaewoong;Cui, Ziyang;Xin, Dongxu;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.4
    • /
    • pp.246-250
    • /
    • 2021
  • TFTs technologies with as high mobility as possible is essential for high-performance large displays. TFTs using nanocrystalline silicon thin films can achieve higher mobility. In this work, the change of the crystalline volume fraction at different hydrogen dilution ratios was investigated by depositing nc-Si:H thin films using PECVD. It was observed that increasing hydrogen dilution ratio increased not only the crystalline volume fraction but also the crystallite size. The thin films with a high crystalline volume fraction (55%) and a low defect density (1017 cm-3·eV-1) were used as top gate TFTs channel layer, leading to a high mobility (55 cm2/V·s). We suggest that TFTs of high mobility to meet the need of display industries can be benefited by the formation of thin film with high crystalline volume fraction as well as low defect density as a channel layer.

The Comparison of the Accuracy in Preparing Small Vancomycin Dosage : Single vs. Double Dilution Method (소용량 Vancomycin 주사액 조제방법의 차이에 의한 정확성 비교: 단일희석방법과 이중희석방법)

  • Shin, Hea Young;Suh, Ok Kyung;Lee, Suk Hyang;Shin, Hyun Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.7 no.2
    • /
    • pp.86-90
    • /
    • 1997
  • This study was to find a more accurate method fur measuring small vancomycin dosages which are commonly used in neonates by comparing single and double dilution method. For single dilution method, 500 mg of vancomycin powder was accurately measured and reconstituted with 5 ml of distilled water to make a concentration of 100 mg/ml. Volumes of 0.05, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.5 ml, which equal the target dosages of 5, 10, 15, 20, 30, 40, and 50 mg, were measured using syringes made by Shina and each sample was further diluted with 2 ml of $5\%$ dextrose. The solution of 100 mg/ml concentration was further diluted with $5\%$ dextrose to make a concentration of 20 mg/ml. Volumes of 0.25, 0.5, 0.75, 1.0, 1.5, 2.0, and 2.5 ml, which correspond to 5, 10, 15, 20, 30, 40, and 50 mg, were sampled by the same Shina's syringe as in single dilution method and then each sample was further diluted to make a total volume of 10 ml. Each sample was analyzed by HPLC. The measured dosages of each sample in both single and double dilution methods were lower than the target dosages; however, e values in double dilution method were higher than those in single dilution method for seven target dosages. Percent target dosages in single dilution method were 65 to $90\%$, while in double dilution method 91 to $94\%$. Statistically significant difference between two groups was shown in 5, 10, 15, 20, and 40 mg dosages (p<0.05). In conclusion, when preparing small vancomycin dosages lower an 20 mg $(volume{\leq}0.2\;ml)$, using Shina's syringes, the double dilution method has a closer value to the target dosage than single dilution method.

  • PDF

Mass Production of Mammalian Cells under Chemostat Cultivation (동물세포의 연속 대량생산에 관한 연구)

  • 이현용;강재구;박형환
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.173-177
    • /
    • 1989
  • Cell density was gradually decreased as the dilution rate was increased under chemostat cultivation of HeLa cells. Maxium cell density was maintained at the dilution rate of 0.020 (1/h) which was far less than the wash-out rate of 0.050 (1/h), Maxium cell productivity of 2 (mL of cells/L/h)was obtained at the dilution rate of 0.030 (1/h) by showing the culture also required maintenance period at low dilution rates, whose result meant the deviation of continuous culture theroy. Methods of indirectly measuring cell density have been introduced to represent mammalian cell growth, which are packed cell volume and oxygen uptake rate, and these values showed good linear relationship with actual cell density by having correlation factor of 0.90. Theoretical maximum oxygen yield, $Y_{O2}^{max}$ and maintenance oxygen consumption rate, m$_{O2}$, were estimated as 4.1$\times$10$^5$ (cells/mmole $O_2$) and 10.71$\times$10$^{-9}$ (mmole $O_2$/cells/h) by employing oxygen yield model.

  • PDF

The Effects of N2 Diluent and Preheated Air on Soot Emission in Laminar Diffusion Flames (층류확산화염에서 질소 첨가와 예열온도가 매연 생성에 미치는 영향)

  • Jeong, Yong-Ki;Lee, Jong-Ho;Jeon, Chung-Hwan;Jang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • An study has been performed with axisymmetric coflow diffusion flames to investigate the influence of air-side fuel side dilution and initial preheated temperature on the soot formation in methan/air flames. Soot quantities are determined by using PLII(Planar Laser Induced Incandescence), such a $C_2$H$_2$ major species(CH$_4$, $O_2$, $N_2$) and temperature are simulated by chemkin code. The numerical analysis was performed with transport properties and detailed reaction mechanisms m axisymmetric coflow diffusion flames. The study of how flame temperature and $N_2$ dilution of air and fuel side influence the soot concentrations is focused. Soot concentrations results on PLII show that preheated temperature contributes to an increase in the soot volume fraction, and soot formation Is more productive to air side dilution than to fuel side dilution. $C_2$H$_2$ concentrations have a similar tendency to soot concentrations.

Surface and Structural Features of a-Si Thin Films Prepared by Various H2/H2+SiH4 Dilution (수소 가스 분율(H2/H2+SiH4)에 따른 비정질 실리콘 박막의 표면 및 구조 분석)

  • Kwon, Jin-Up
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.2
    • /
    • pp.39-43
    • /
    • 2011
  • Amorphous silicon thin film was deposited by Plasma Enhanced Chemical Vapor Deposition (PECVD). Each films were prepared in different dilution in the chamber gas. As a result, silicon crystallites and crystal volume fraction was increased with raising the hydrogen dilution in the gas and optical band gap was decreased. Increasement of the hydrogen contents in the chamber affected on surface roughness. In this study, thickness and surface roughness of the a-Si thin film by different hydrogen dilution was investigated by various techniques.

A Study on the Plasma Enhanced Hot-wire CVD Grown Miorocrystalline Silicon Films for Photovoltaic Device Applications (태양전지 응용을 위한 플라즈마 열선 화학기상증착법으로 성장한 미세결정 실리콘에 관한 연구)

  • 유진수;임동건;고재경;박중현;이준신
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.632-635
    • /
    • 2001
  • Microcrystalline Si films have been deposited by using five W-wire filaments of 0.5 mm diameter for hot-wire chemical vapor deposition (HWCVD). We compared the HWCVD grown films with the film exposed to transformer couple plasma system for the modification of seed layer. W-wire filament temperature was maintained below 1600$^{\circ}C$ to avoid metal contamination by thermal evaporation at the filament. Deposition conditions were varied with H$_2$dilution ratio, with and without plasma treatment. From the Raman spectra analysis, we observed that the film crystallization was strongly influenced by the H$_2$dilution ratio and weakly depended on the distance between the wire and a substrate. We were able to achieve the crystalline volume fraction of about 70% with an SiH$_4$/H$_2$ratio of 1.3%, a wire temperature of 1514$^{\circ}C$, a substrate separation distance of 4cm, and a chamber pressure of 38 mTorr. We investigated the influence of ${\mu}$c-Si film properties by using a plasma treatment. This article also deals with the influence of the H$_2$dilution ratio in crystallization modification.

  • PDF

Quantitative Analysis of the Amount of Aluminium Dissolved in Phosphoric Acid

  • Moon, Sungmo;Yang, Cheolnam
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.4
    • /
    • pp.231-236
    • /
    • 2017
  • The present work addresses how to measure the amount of dissolved aluminum in phosphoric acid, based on volumetric and gravimetric measurements of the precipitates formed by reaction between the $H_3PO_4$ solution containing dissolved aluminum ions and 10 % KF solution. The volume of the precipitates increased with dilution of the dissolved aluminum-containing $H_3PO_4$ solution up to 1/4 dilution above which it decreased with further dilution. The lowered amounts of the precipitates at low dilution less than 1/4 and high dilution more than 1/4 are attributed to high acidity of the solution and decreased amount of dissolved aluminum in the solution, respectively. Volumetric measurement of the amount of precipitates was found not to be very reliable with the experiments, while weight measurement of the precipitates after drying for 80 min at $60^{\circ}C$ appeared to be very reproducible. In the present work, it is suggested that the amount of Al dissolved in 85 % $H_3PO_4$ solution can be calculated by multiplying 50 to the weight of precipitate obtained by reacting 8 ml of 1/4 diluted $H_3PO_4$ solution containing dissolved aluminum ions with 6 ml of 10 % KF solution.

Comparison of the Measurement of the Injection Rate of Radioactive Drugs Using 99mTc in Nuclear Medicine (핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교)

  • Son, Sang-Joon;Park, Jeong-Kyu;Jung, Dong-Kyung;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.97-103
    • /
    • 2020
  • This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radio-pharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).