• Title/Summary/Keyword: Digital treatment

Search Result 1,131, Processing Time 0.029 seconds

Comparison of condylar guidance using ARCUSdigma 2 and Checkbite (ARCUSdigma 2와 Checkbite를 사용하여 측정한 과로경사각 비교)

  • Lee, Dong-In;Lee, Chang-Hee;Son, Mee-Kyoung;Chung, Chae-Heon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: Nowadays, checkbite methods and a digital sensor are used to analyze the movement of mandible. However, there are no study comparing two methods. Therefore, this study has compared measuring the condylar inclination methods by using the new ARCUSdigma 2 system and the checkbite method. Materials and methods: Young 20 adults without any orthodontic treatment experiences, missing teeth, and restorations with the change of occlusal plane were tested. Angles of condylar path were measured 3 times each, based on Camper's line, by using two methods. KaVo PROTAR Evo 7 semi-adjustable articulator was used and the data were statistically analyzed. Results: 1. The anterior sagittal condylar inclination by ARCUSdigma 2 system were measured as $26.97^{\circ}({\pm}7.38^{\circ})$ on the left side and $29.80^{\circ}({\pm}8.19^{\circ})$ on the right side. The lateral condylar inclination were measured as $5.75^{\circ}({\pm}3.47^{\circ})$ on the left side and $8.10^{\circ}({\pm}4.98^{\circ})$ on the right side. 2. The anterior sagittal condylar inclination by checkbite method were measured as $25.20^{\circ}({\pm}6.53^{\circ})$ on the left side and $28.18^{\circ}({\pm}7.38^{\circ})$ on the right side. The lateral condylar inclination were measured as $10.97^{\circ}({\pm}5.63^{\circ})$ on the left side and $12.03^{\circ}({\pm}5.22^{\circ})$ on the right side. There was no statistically significant difference between male and female (P>.05). 3. The lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05). Conclusion: In Both of 2 methods, there was no statistically significant difference between male and female (P>.05). However, the lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05).

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

The Tooth Size RelaTionship Between Crowding Patients and Normal Subjects in Korean (총생치열을 갖는 교정환자와 정상인의 치아크기 비교)

  • Han, Man-Deuk;Jeon, Eun-Sook
    • Journal of dental hygiene science
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • This study was undertaken to compare the tooth and arch size between crowding patient and normal subjects. Two group of dental casts were selected on the basis of crowding patients and normal subjects. One group, consisting of 40 pair of dental casts(20 male and 20 female), exhibited noncrowded dentitions. A second group, consisting of 40 pairs of dental cast(21 male and 21 female), exhibited remarkably crowding need for orthodontic treatment. Tooth width measurements were made with a sliding digital caliper with Vernier scale neared 0.01 mm. Mean, standard deviation, T-test of the following parameters were used to compare two group : individual mesiodistal crown widths, arch width and arch length. The following result were obtained. In the mesiodistal crown widths, normal subjects had generalized larger teeth than Wheeler's results(human tooth size index), except for maxillary central incisor, maxillary 2nd premolar, mandibular canine, and mandibular 1st molar. In the orthodontic patients with crowded dentitions, the mesiodistal tooth crown widths were generalized larger teeth than noncrowded normal subjects. In the arch width and arch length, the crowded dentition group had smaller arch width and arch length than the normal group.

  • PDF

A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging (3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안)

  • Chang, Hye-Sook;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.313-325
    • /
    • 2002
  • Three-dimensional CT imaging is efficient in examining specific structures in the craniofacial area by reproducing actual measurements through minimization of errors from patient movement and image magnification. Due to the rapid development of digital image technology and the expansion of treatment range a need for developing three -dimensional analysis has become urgent. Therefore the purpose of this study was to evaluate the percentage of error and magnification of three-dimensional CT using a dried skull and Vworks $program^{TM}$ (Cybermed Inc., Seoul, Korea) and also to obtain landmarks that are easy to designate and reproduce in three-dimensional images using the Vmorph-proto $program^{TM}$ (Cybermed Inc., Seoul, Korea). The following conclusions were obtained, 1. In the comparison of actual measurements from the dried skull and the three-dimensional image obtained from the Vworks program, the mean error was 0.99mm and the magnification was 1.04%. 2. Clinically useful hard tissue landmarks from three-dimensional images were Supraorbitale, Lateral orbital margin, Infraorbitale, Nasion, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch and Basion. 3. Clinically useful soft tissue landmarks from three-dimensional images were Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton and Preaurale. The Vworks program can be considered a clinically efficient tool to produce and measure three-dimensional images. Most of the hard and soft tissue landmarks proposed above are anatomically important points which are also easily reproducible and designated. These landmarks can be beneficial in three-dimensional diagnosis and the prediction of changes before and after surgery.

Feasibility of Reflecting Improvement of Tumor Hypoxia by Mild Hyperthermia in Experimental Mouse Tumors with $^18F-Fluoromisonidazole$ (저온온열치료에 의한 종양 내 저산소상태 개선효과를 $^18F$-Fluoromisonidazole의 섭취 변화를 이용한 평가)

  • Lee Sang-wook;Ryu Jin Sook;Oh Seung Joon;Im Ki Chun;Chen Gi Jeong;Lee So Ryung;Song Do Young;Im Soo Jeong;Moon Eun Sook;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Lee Kyeong Ryong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.288-297
    • /
    • 2004
  • Puporse: The aims of this study were to evaluate the change of $[^18F]fluoromisonidazole$($[^18F]FMISO$) uptake in C3H mouse squamous cell carcinoma-VII (SCC-VII) treated with mild hyperthermia ($42^{circ}C$) and nicotinamide and to assess the biodistribution of the markers in normal tissues under similar conditions. Methods and Materials: $[^18F]FMISO$ was producedby our hospital. Female C3H mice with a C3H SCC-VII tumor grown on their extremities were used. Tumors were size matched. Non-anaesthetized, tumor-bearing mice underwent control or mild hyperthermia at $42^{circ}C$ for 60 min with nicotinamide (50 mg/kg i.p. injected) and were examined by gamma counter, autoradiography and animal PET scan 3 hours after tracer i.v. injected with breathing room air, The biodistribution of these agents were obtained at 3 h after $[^18F]FMISO$ injection. Blood, tumor, muscle, heart, lung, liver, kidney, brain, bone, spleen, and intestine were removed, counted for radioactivity and weighed. The tumor and liver were frozen and cut with a cryomicrotome into 10- um sections. The spatial distribution of radioactivity from the tissue sections was determined with digital autoradiography. Results: The mild hyperthermia with nicotinamide treatment had only slight effects on the biodistribution of either marker in normal tissues. We observed that the whole tumor radioactivity uptake ratios were higher in the control mice than in the mild hyperthermia with nicotinamide treated mice for $[^18F]FMISO$ ($1.56{\pm}1.03$ vs. $0.67{\pm}0.30$; p=0.063). In addition, autoradiography and animal PET scan demonstrated that the area and intensity of $[^18F]FMISO$ uptake was significantly decreased. Conclusion: Mild hyperthermla and nicotinamide significantly improved tumor hypoxia using $[^18F]FMISO$ and this uptake reflected tumor hypoxic status.

Stability and Damage Evaluation of the Buddha Triad and 16 Rock-Carved Arhat Statues at Seongbulsa Temple in Cheonan, Korea (천안 성불사 마애석가삼존과 16나한상의 손상도 및 안정성 평가)

  • Yang, Hyeri;Lee, Chan Hee;Jo, Young Hoon
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.4
    • /
    • pp.78-99
    • /
    • 2020
  • The Buddha triad and 16 Arhat statues carved on the rock surface at Seongbulsa temple is the only domestic remaining example of all 16 Arhats, so its academic value is very high. However, it is severely damaged and so required a stability evaluation through study of digital documentation and precise diagnosis for the purpose of comprehensive conservation. This process established that the Buddha statues were of similar scale, while the Arhats showed a wide variety of sizes, and the two kith and kin in the volume were larger than the Arhats. It was estimated that the statues of food for Buddha are similar to the Arhat statues, and most of the statues are well-formed. The rock used to carve the Buddha statues is banded gneiss with distinct foliation, alternating between white bands of quartz and feldspar and black bands composed of biotite. The Buddha statues have been damaged by physical weathering, discoloration, and biological contamination. In damage evaluations, joint (3.6 crack index), peeling (5.2%), exfoliation (1.7%), and falling off (0.1%) were observed on the rock surface of the Buddha statues. In particular, due to severe biological weathering, stage 9 and 10 biological coverage of the rock surface accounted for 57.5% of the total area, and stages 5 to 8 also accounted for a high share at 22.3%. The discoloration factors were shown to be dark brown and white with Fe, Ca, and S, and a large amount of C detected in the blackened contaminants, and the damage weight high in all areas. Discontinuities in different directions were identified in the rock surface. Analysis of potential rock failure types indicated that there is a possibility of plane and toppling failure, but wedge failure is unlikely to occur. The mean ultrasonic velocity of the main rock surface was 2,463m/sec, the lower part of the left side with a large number of joints was relatively low, and the highly weathered (HW) type to the completely weathered (CW) type concentrated distribution, showing weak properties. For the Buddha statues, conservation treatment is required for about 14.9% of micro cracks and 58.9% of exfoliation cracks. In addition, in order to improve the conservation environment of the Buddha statues, maintenance of drainage and ground preparations for the rock surface gradient and plants are necessary, and protection facilities should be reviewed for long-term conservation and management purposes.

A Study on Human-Robot Interaction Trends Using BERTopic (BERTopic을 활용한 인간-로봇 상호작용 동향 연구)

  • Jeonghun Kim;Kee-Young Kwahk
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.185-209
    • /
    • 2023
  • With the advent of the 4th industrial revolution, various technologies have received much attention. Technologies related to the 4th industry include the Internet of Things (IoT), big data, artificial intelligence, virtual reality (VR), 3D printers, and robotics, and these technologies are often converged. In particular, the robotics field is combined with technologies such as big data, artificial intelligence, VR, and digital twins. Accordingly, much research using robotics is being conducted, which is applied to distribution, airports, hotels, restaurants, and transportation fields. In the given situation, research on human-robot interaction is attracting attention, but it has not yet reached the level of user satisfaction. However, research on robots capable of perfect communication is steadily being conducted, and it is expected that it will be able to replace human emotional labor. Therefore, it is necessary to discuss whether the current human-robot interaction technology can be applied to business. To this end, this study first examines the trend of human-robot interaction technology. Second, we compare LDA (Latent Dirichlet Allocation) topic modeling and BERTopic topic modeling methods. As a result, we found that the concept of human-robot interaction and basic interaction was discussed in the studies from 1992 to 2002. From 2003 to 2012, many studies on social expression were conducted, and studies related to judgment such as face detection and recognition were conducted. In the studies from 2013 to 2022, service topics such as elderly nursing, education, and autism treatment appeared, and research on social expression continued. However, it seems that it has not yet reached the level that can be applied to business. As a result of comparing LDA (Latent Dirichlet Allocation) topic modeling and the BERTopic topic modeling method, it was confirmed that BERTopic is a superior method to LDA.

The Effects of the Revised Elderly Fixed Outpatient Copayment on the Health Utilization of the Elderly (노인외래정액제 개선이 고령층의 의료이용에 미친 영향)

  • Li-hyun Kim;Gyeong-Min Lee;Woo-Ri Lee;Ki-Bong Yoo
    • Health Policy and Management
    • /
    • v.34 no.2
    • /
    • pp.196-210
    • /
    • 2024
  • Background: In January 2018, revised elderly fixed outpatient copayment for the elderly were implemented. When people ages 65 years and older receive outpatient treatment at clinic-level medical institutions (clinic, dental clinic, Korean medicine clinic), with medical expenses exceeding 15,000 won but not exceeding 25,000 won, their copayment rates have decreased differentially from 30%. This study aimed to examine the changes of health utilization of elderly after revised elderly fixed outpatient copayment. Methods: We used Korea health panel data from 2016 to 2018. The time period is divided into before and after the revised elderly fixed outpatient copayment. We conducted Poisson segmented regression to estimate the changes in outpatient utilization and inpatient utilization and conducted segmented regression to estimate the changes in medical expenses. Results: Immediately after the revised policy, the number of clinic and Korean medicine outpatient visits of medical expenses under 15,000 won decreased. But the number of clinic outpatient visits in the range of 15,000 to 20,000 won and Korean medicine clinic in the range of 20,000 to 25,000 won increased. Copayment in outpatient temporarily decreased. The inpatient admission rates and total medical expenses temporarily decreased but increased again. Conclusion: We confirmed the temporary increase in outpatient utilization in the medical expense segment with reduced copayment rates. And a temporary decrease in medical expenses followed by an increase again. To reduce the burden of medical expense among elderly in the long run, efforts to establish chronic disease management policies aimed at preventing disease occurrence and deterioration in advance need to continue.