• 제목/요약/키워드: Digital X-ray System

검색결과 225건 처리시간 0.027초

비정질 셀레늄 디지털 X선 검출기에 대한 잔류 전하 제거 기술 (Latent Charge Erasing Technique for a-Se Digital X-ray Detector)

  • 강상식;최장용;박지군;조진욱;문치웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.505-508
    • /
    • 2001
  • Currently there is much interested in removing latent charge that is caused to latent image effect and blurring of obtained image as well as reduction of x-ray conversion efficiency in digital radiography system. To remove latent charge a-Se film is irradiated by light with 3500 lux using halogen lamp and optical fiber. We measured dark current and photosensitivity to analyze removing effect of latent charge, then compared with and without light erasing method. The reduction of measured signal due to latent charge effect was 32.3%, and the removal effect of latent charge by using light erase method was its 95.5%.

  • PDF

암모기 흡혈과정에 대한 실험적 연구 (Experimental research on blood sucking phenomena of a female mosquito)

  • 김보흠;이정엽;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

디지탈 X-선 촬영시스템의 영상 및 물리적 특성 분석 (Characterization of Imaging and Physical Properties in Digital Radiography System)

  • 김종효;이태수;박광석;한만청;이충웅;민병구
    • 대한전자공학회논문지
    • /
    • 제26권7호
    • /
    • pp.112-124
    • /
    • 1989
  • 최근 본 연구팀에서 기존의 선 조사방식 디지탈 X-선 촬영시스템의 단점을 보완하여 촬영시간을 0.7초로 단축시키고 환자에의 X-선 조사량을 3mR 정도로 감소시킨 디지탈 X-선 촬영시스템을 개발한 바, 이 논문에서는 이 시스템의 감도 특성, 산란 성분 구성률, 양자검출 효율, 변조전달함수, 그리고 콘트라스트 상세도 등과 같은 물리적 및 영상특성들을 조사함으로써 그 촬영성능을 평가하였다. 조사 결과 이 시스템의 감도특성은 입사에너지에 비례하며, 기존의 필름-스크린 보다 적은 X-선 조사량으로도 더 우수한 콘트라스트 해상도를 지녔음이 나타났다. 그 이유는 뛰어난 산란선 제거능력과 양자검출 효율 때문인 것으로 생각된다.

  • PDF

평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구 (Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance)

  • 박지군;최장용;강상식;이동길;석대우;남상희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • 의료영상 분야에서의 디지털화가 시도되면서부터 평판형 디지털 영상검출기가 일반촬영 및 투시영상을 비롯한 다양한 영상 획득 장치에의 적용을 위해 꾸준히 연구, 개발되어져 왔다. 본 연구는 비정질 셀레늄을 이용한 디지털 방사선 검출기를 통해 획득된 영상의 평가를 통해 순수 국내 기술로 개발중인 디지털 방사선 검출기의 임상 사용여부를 확인하고, 영상평가의 주요인자인 modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) 이용하여 정량적인 값을 도출함으로써 의료영상평가에 필요한 측정 방법 및 그 기초 자료의 제공을 그 목적으로 한다. 비정질 셀레늄을 이용한 디지털 방사선 검출기는 pixel pitch가 $139\;{\mu}m$이며, 전체 active area은 $14{\times}8.5\;inch^2$, 전체 pixel의 수는 3.9백만개이다. 디지털 X-선 검출기에서 광도전체로서 비정질 셀레늄은 TFT 평판 패널 위에 진공 증착된다. 비정질 셀레늄의 두께는 $500\;{\mu}m$이다. 디지털 방사선 검출기의 성능을 평가하기 위해 민감도, 선형성, MTF, NPS, 그리고 DQE가 측정되었다. 선형성 평가에서는 뛰어난 선형성[($r^2$)=0.9693]을 보였다. 측정된 민감도는 인가전압 $10\;V/{\mu}m$에서 $4.16{\times}10^6\;ehp/pixel{\cdot}mR$이며, MTF는 2.5\;lp/mm에서 52%이다. 그리고 DQE는 1.5\;lp/mm에서 75%이다. 본 연구를 통해 영상평가 측정 기술의 기본적 토대를 마련하고, 측정된 값은 국내 기술로 개발중인 비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기의 임상적 사용가치가 충분함을 뒷받침할 수 있는 기초 자료로서 제공될 수 있을 것으로 판단된다.

  • PDF

Effect of DyFeO3 Addition on Crystal Structure and Ferrcelectricity of the BiFeO3-PbTiO3 System

  • Kim, Seong-Seog;Kwon, Jong-Uk;Cheon, Chae Il
    • 한국세라믹학회지
    • /
    • 제42권5호
    • /
    • pp.299-303
    • /
    • 2005
  • The crystal structure and ferroelectricity of the $(1-x)BiFeO_3\;(BF)-xPbTiO_3$ (PT) ceramic system with the addition of $DyFeO_3$ (DF) have been investigated for attaining a high temperature piezoelectric material. This study is focused on the relation between crystal structure and ferroelectric property with the addition of DF over the phase boundary in the (1-x)BF-xPT system. Hysteresis curves of polarization-electric field at room temperature have been measured. The X-ray and neutron diffraction data were analyzed by the rietveld refinement method. The addition of 0.1 mole DF into BF-PT system greatly increases the ferroelectric remanant polarization Pr values, e.g. 17 ${\mu}C/cm^2$ in 0.6BF-yDF-(0.4-y)PT and 31${\mu}C/cm^2$ in 0.5BF-yDF-(0.5.y)PT, respectively. The improved Pr value has been discussed in relation with crystal structure and electrical property.

진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008- (General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008-)

  • 강희두;동경래;권대철;최준구;정재호;정재은;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안 (Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography)

  • 심지나;이영진
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.139-145
    • /
    • 2021
  • 본 연구는 흉부 X-ray 검사 시 디지털 영상의 적절한 유효 Detector exposure index (DEI) 범위 내의 영상의 Dose area product (DAP)값과 유효선량을 비교함으로써 적절한 관전압의 범위를 확인하고자 하였다. GE Definium 8000을 사용하여 흉부팬텀을 이용한 Chest PA 검사를 재현하였다. kVp range는 60~130 kVp, mAs range는 2.5 ~ 40 mAs로 설정하였다. 획득한 영상을 유효한 DEI 범위의 영상으로 분류하고 측정한 DAP을 이용하여 PC-Based Monte Carlo Program을 통해 유효선량을 계산하였다. 영상의 정량적 평가를 하기 위해 Picture archiving and communication system을 이용하여 흉추, 갈비뼈가 포함된 폐야부위, 갈비뼈가 포함되지 않은 폐야부위, 간 등 총 네 부분의 Signal to noise ratio (SNR)를 측정하였다. 관전압 별 그룹의 유의성은 Kruskal-wallis test와 사후검정으로 Mann-whitney test를 시행하여 검증하였으며 검증에 사용된 신뢰구간은 95%이다. 총 13개의 관전압 중 적정한 유효 DEI 범위안에 포함된 네개의 관전압 (60~90 kVp)을 각각 비교하였을 때, DAP는 60 kVp를 기준으로 80 kVp, 90 kVp를 비교한 결과에서만 유의한 차이를 보였다 (p= 0.034, 0.021). 유효선량은 모든 관전압 그룹에서 유의한 차이를 보이지 않았다 (p>0.05). SNR은 간 부위에서 80 kVp와 90 kVp를 제외한 모든 그룹에서 유의한 차이를 보였다 (p<0.05). 그러므로 디지털 환경에서 적정한 흉부 X-ray 영상의 농도를 나타내기 위해 100 kVp 이상의 고관전압은 환자 선량 및 영상 측면에서 재고할 필요성이 있다고 사료된다.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

의료 영상 판독 결과의 DICOM SR 변환 (Conversion of Radiology Report into DICOM SR)

  • 김용수;신승용
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권3호
    • /
    • pp.331-337
    • /
    • 2005
  • DICOM(Digital Imaging and Communications on Medicine) 표준은 2004년 4월에 발표된 "Supplement 23:DICOM SR(Structured Reporting)"을 통해 모든 임상정보의 표준화된 교환이 가능하도록 확장함으로써 의사의 판독보고서와 신체의 특정 부위와의 관계를 체계적으로 연결할 수 있게 되었다. DICOM SR은 정보를 정확하게 표현하기 위해 코드체계를 사용하며, 구성 항목들의 계층적인 트리로써 구조화된 정보를 표현할 수 있다. 본 논문에서는 병원정보시스템의 영상 판독결과 보고서를 분석하여 발견(finding), 결론(conclusion) 및 권고(recommendation)로 세분화하고 구조화한 후 실제로 의사가 진료에 활용할 수 있도록 DICOM SR 시스템을 구현하였다. X-ray와 같은 영상 데이터는 판독결과나 환자의 정보와 같은 텍스트 데이터와 별도로 관리되고 있다. DICOM SR로 표현된 판독결과 보고서는 영상에 대한 참조가 가능하므로 텍스트와 영상이 통합된 정보를 제공할 수 있다.

  • PDF

디지털 X선 영상을 이용한 치아 와동 컴퓨터 보조 검출 시스템 연구 (A Study of Computer-aided Detection System for Dental Cavity on Digital X-ray Image)

  • 허창회;김민정;조현종
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1424-1429
    • /
    • 2016
  • Segmentation is one of the first steps in most diagnosis systems for characterization of dental caries in an early stage. The purpose of automatic dental cavity detection system is helping dentist to make more precise diagnosis. We proposed the semi-automatic method for the segmentation of dental caries on digital x-ray images. Based on a manually and roughly selected ROI (Region of Interest), it calculated the contour for the dental cavity. A snake algorithm which is one of active contour models repetitively refined the initial contour and self-examination and correction on the segmentation result. Seven phantom tooth from incisor to molar were made for the evaluation of the developed algorithm. They contained a different form of cavities and each phantom tooth has two dental cavities. From 14 dental cavities, twelve cavities were accurately detected including small cavities. And two cavities were segmented partly. It demonstrates the practical feasibility of the dental lesion detection using Computer-aided Detection (CADe).