• Title/Summary/Keyword: Digital Therapy

Search Result 639, Processing Time 0.028 seconds

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

A Systematic Study of the Intervention Effect of Social Stories in Children with Sleep Disorders (수면장애 아동을 위한 사회적 이야기 중재 효과: 체계적 고찰)

  • Kim, Ji-Ho;Yoo, Eun-Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.21 no.2
    • /
    • pp.69-83
    • /
    • 2023
  • Objective : This study sought to systematically examine the intervention effect of social stories when applied in relation to children with sleep disorders. Methods : Studies available in the SCOPUS, ScienceDirect, PsycArticles, and PubMed databases that were published from 2001 to 2022 were searched. The keywords used for the search were as follows: ("social story" OR "social stories") AND ("sleep" OR "sleep disorders" OR "sleep wake disorder bedtimes" OR "sleep initiation and maintenance disorders" OR "sleep wake disorder" OR "sleep arousal disorders"). Based on the selection criteria, six experimental studies were selected and analyzed. Results : The selected studies were two randomized controlled trials, three individual trials, and one case study. The subjects were mostly children diagnosed with autism spectrum disorder who were school-aged or adolescent. The intervention types were often complex interventions, including social stories and other interventions, while the durations of the interventions varied from one day to more than 40 days. The interventions had a positive effect on the subjects' sleep quality, with night wakings, sleep onset delay, and sleep anxiety all being improved. As standardized assessment tools to evaluate the effectiveness of social stories, the Child Sleep Habits Questionnaire and the Child Behavior Checklist were used in two papers each, and were the most commonly used. As non-standardized assessment tools, each of the four papers used turbulence and sleep diaries as assessment tools. Conclusion : The effect of social story mediation can be divided into sleep quality and sleep-related behavior. In terms of sleep quality, studies showing improvements in night wakings, sleep onset delay, and sleep anxiety accounted for a large proportion of the sample. The detailed effect area of sleep quality showed a significant improvement after the interventions in most studies, and in all six studies analyzed in the present study, the continuation of the effect after the intervention was confirmed via follow-up tests. Thus, the findings of this study are expected to be helpful when applying social stories in children with sleep disorders in clinical practice due to presenting the intervention effects, outcome evaluation tools, and intervention periods in children with sleep disorders in prior investigations involving social stories.

A study anxiety of mothers who have hospitalized ill children Focusing on the comparison of korean mothers with multicultural family mothers (입원 환아 어머니의 불안에 관한 연구: 한국인 어머니와 다문화가정 어머니 비교를 중심으로)

  • Oh, Jae-Woo;Moon, Young-Sook
    • Journal of Digital Convergence
    • /
    • v.10 no.6
    • /
    • pp.311-319
    • /
    • 2012
  • This study, by grasping the degree of anxiety of Korean mothers and multicultural family mothers because of their hospitalized children, was aimed to arrange the basic data for developing the program to help the mothers of Korea and multicultural family reduce the anxiety happening due to the hospitalization of their children and adapt to their environment. Methods: The subjects of the study were a total of 200 people composed of 100 multicultural family mothers, and 100 Korean mothers respectively whose children were hospitalized in the pediatric department of K university hospital located in Daejeon City. And the period of data collection was from Aug 1, 2010 to Aug 31, 2010.As a study tool, the measuring tool of Kim Jeong Taek(1978), which STAI of Sielberger(1972) was adapted to Koreans, was used.The collected data was analyzed using SPSS WIN 12.0. Results. A result of the state anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, Korean mothers 2.11, multicultural family mothers 2.17, result of temperament anxiety showed Korean mothers 2.09, multicultural family mothers 1.94. As a result of comparing the anxiety of the Korean mothers with that of the multicultural family mothers of the inpatient children, there was no difference between groups in both temperament anxiety and state anxiety. In a situation of anxiety, when there was no explanation of the treatment or therapy, both Korean mothers and multicultural family mothers showed the severe anxiety. In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was not a statistically significant result in anxiety according to general characteristics of the inpatient children of korean family mothers, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). In the degree of anxiety according to the general characteristics of the mothers of the inpatient children, there was a significant difference in state anxiety according to the state of average monthly income in Korean mothers(P<.05), however, there was a significant one in temperament anxiety in the course of perceiving a test method in multicultural family mothers(P<.05). Conclusion: Through the results of the study above, no matter what socio-demographic characteristics of the mothers of the inpatient children are, regardless of the general characteristics of the inpatient children, it was found out that most of mothers felt anxiety.

Analysis of alveolar molding effects in infants with bilateral cleft lip and palate when treated with pre-surgical naso-alveolar molding appliance (양측성 순구개열 신생아 환자의 수술전 비치조 정형장치 치료에 의한 치조골 조형(molding) 효과의 분석)

  • Nahm, Dong-Seok;Yang, Won-Sik;Baek, Seung-Hak;Kim, Sukwha
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.649-661
    • /
    • 1999
  • The goals of this study were 1) to present pre-surgical naso-alveolar molding (PNAM) appliance for bilateral cleft lip and palate treatment and 2) to evaluate the effects of the PNAM appliance on the alveolar molding of the premaxilla and the lateral segments. Subjects consisted of 8 bilateral cleft lip and palate infants (7 males and 1 female, mean age at first visit = 61.6 days after birth) who were treated with PNAM appliances in Department of Orthodontics, Seoul National University Dental Hospital. Average alveolar cleft gap between the premaxilla and the lateral segment was $8.09{\pm}5.03mm$ and average duration of alveolar molding treatment was $8.8{\pm}3.1$ weeks. These patients' models were obtained at initial visit (T0) and after alveolar molding (T1). 20 linear and 14 angular variables were measured by using photometry and digital caliper, All statistical analyses were performed by Microsoft Excel 97 program. Paired t-test was used to discriminate the effect of alveolar molding by PNAM appliance. 1. Closure of the alveolar cleft gap in bilateral cleft cases by molding therapy was completed successfully, 2. Alveolar molding inhibited outward growth of lateral segments and produced inward bending of lateral segments. 3. By bending the anterior part of the vomer, the premaxilla could be rotated and moved. posteriorly via alveolar molding. Conclusion This appliance can be applied to bilateral cleft lip and palate infants with satisfactory results before cheiloplasty.

  • PDF

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

A study on developing a new self-esteem measurement test adopting DAP and drafting the direction of digitalizing measurement program of DAP (청소년 자존감 DAP 인물화 검사 개발 및 디지털화 측정 시스템 방향성 연구)

  • Woo, Sungju;Park, Chongwook
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This is to develop a new way of testing self-esteem by adopting DAP(Draw a Person) test and to make a platform to digitalize it for young people in the adolescent stage. This approach is to get high effectiveness of the self-esteem measurement using DAP test, including some personal inner situations which can be easily missed in the large statistical analysis. The other objective of this study is digitalize to recover limits of DAP test in the subjective rating standard. It is based on the distribution of the figure drawing expressed numerically by the anxiety index of Handler. For these two examinations, we made experiment through 4 stages with second grade middle school 73 students from July 30th to October 31th in 2009 during 4 months. Firstly, we executed 'Self Values Test' for all 73 people, and divided them into two groups; one is high self-esteem group of 36 people, the other is low self-esteem group of 37 people. Secondly, we regrouped them following D (Depression), Pd (Psychopathic Deviate), Sc (Schizophrenia) scales of MMPI; one is high self-esteem group of 7 people, the other is low self-esteem group of 13 people. Thirdly, we conducted DAP test separately for these 20 people. We intended to verify necessity and appropriateness of direction of 'Digitalizing Measurement System' by comparing and analyzing relation between DAP and Self-esteem following evaluation criteria which has similarity in 3 tests, after executing DAP to reflect peculiarity of adolescents sufficiently. We compared and analyzed result abstracted by sampling DAP test of two groups; One is high self-esteem group of 2 people, the other is low self-esteem group of 2 people; to confirm whether we can improve limitation that original psychological testing has by comparing mutual reliance of measurement test. Finally, with DAP test gained from correlations between self-esteem and melancholia following as above-mentioned steps, we discovered possibility of realization to get a concrete and individual criteria of evaluation based on Expert System as a way of enhancing accessibility in quantitative manner. 'Digitalizing Measurement Program' of DAP test suggested in this study promote results' reliability based on existing tests and measurement.

  • PDF

CROSS-SECTIONAL MORPHOLOGY AND MINIMUM CANAL WALL WIDTHS IN C-SHAPED ROOT OF MANDIBULAR MOLARS (C-shaped canal의 절단면 분석을 통한 근관형태의 변화와 근관과 치아외벽간의 최소거리 분석에 관한 연구)

  • Song, Byung-Chul;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • The C-shaped canal system is an anatomical variation mostly seen in mandibular second molars, although it can also occur in maxillary and other mandibular molars. The main anatomical feature of C-shaped canals is the presence of fins or web connecting the individual root canals. The complexity of C-shaped canals prevents these canals from being cleaned, shaped, and obturated effectively during root canal therapy, and sometimes it leads to an iatrogenic perforation from the extravagant preparation. The purpose of this study was to provide further knowledge of the anatomical configuration and the minimal thickness of dentinal wall according to the level of the root. Thirty extracted mandibular second molars with fused roots and longitudinal grooves on lingual or buccal surface of the root were collected from a native Korean population. The photo images and radiographs from buccal, lingual, apical direction were taken. After access cavity was prepared, teeth were placed in 5.25% sodium hypochlorite solution for 2 hours to dissolve the organic tissue of the root surface and from the root canal system. After bench dried and all the teeth were embedded in a self-curing resin. Each block was sectioned using a microtome (Accutom-50, Struers, Denmark) at interval of 1 mm. The sectioned surface photograph was taken using a digital camera (Coolpix 995, Nikon, Japan) connected to the microscope. 197 images were evaluated for canal configurations and the minimal thickness of dentinal wall between canal and external wall using 'Root Thickness Gauge Program' designed with Visual Basic. The results were as follows : 1. At the orifice level of all teeth, the most frequent observed configuration was Melton's Type C I (73%), however the patterns were changed to type C II and C III when the sections were observed at the apical third. On the other hand, the type C III was observed at the orifice level of only 2 teeth but this type could be seen at apical region of the rest of the teeth. 2. The C-shaped canal showed continuous and semi-colon shape at the orifice level, but at the apical portion of the canal there was high possibility of having 2 or 3 canals 3. Lingual wall was thinner than buccal wall at coronal, middle, apical thirds of root but there was no statistical differences.

Effects on the Thermal Change of the Face Follow Electroacupunctyre on Hapkok($LI_4$), Sangan($LI_3$) (合谷($LI_4$), 三間($LI_3$)의 電針刺戟이 顔面部 領域 溫度變化에 미치는 影響)

  • Yun, Jeong-hun;Kim, Jong-Han;Hwang, Chung-yeon;Lim, Kyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.2
    • /
    • pp.222-247
    • /
    • 1999
  • The back ground and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it has been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. As electroacupuncture is one of acupuncture treatments, it will show more objective index to observe the meridian and qi xue(氣血) phenomenon. And then, I studied the effects on the thermal change of the face following electroacupuncture treatment. Objective and Methods : This study was performed from January 1999 to March 1999 on 10 healthy students. The objective was divided into three groups, those were the control group A(n=10), the group B(n=10) of electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and the group C(n=10) of electroacupuncture on Shinmun($H_7$), T' ongni($H_5$). First, in the control group A, we took a picture for 10 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.I.) and did 3min after, 10min after, 15min after, 25min after, 45min after respectively. Second, in the electroacupuncture treatment group B, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and took a picture immediately(3min after), 10min after, 15min after and remove needle and took a picture in the same way respectively. Third, in the electroacupuncture treatment group C, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Shinmun($H_7$), T'ongni($H_5$) and took a picture in the second way respectively. Results: 1. In healthy men, average skin temperture about Yonghyang($LI_{20}$) area was higher than Soryo($G_{25}$) or Chich'ang($S_4$) area. They were Soryo($G_{25}$) area $31.495{\pm}0.766^{\circ}C$, Rt. Yonghyang($LI_{20}$) area $31.664{\pm}0.936^{\circ}C$, Lt. Yonghyang ($LI_{20}$)area $31.686{\pm}0.767^{\circ}C$, Rt. Chich'ang($S_4$) area $31.226{\pm}0.875^{\circ}$, Lt. Chich'ang ($S_4$) area $31.453{\pm}0.855^{\circ}C$. 2. In the control group A, the skin temperature of Soryo($G_{25}$) showed the increase or decrease in below ${\Delta}0.1^{\circ}C\;except\;0.265{\pm}0.594^{\circ}C$ in 25min, but not significantly. 3. About Soryo($G_{25}$) area, the skin temperature decreased significantly after electroacupuncture immediately. ${\Delta}T $of the group B was $-0.970{\pm}0.87\;1^{\circ}C$, which was larger than one of the group C which was $-0.707{\pm}0.624^{\circ}C$ at 3min. And then ${\Delta}T$ of the group C was increase valuable at 25min, 45min. 4. About Yonghyang($L1_{25}$) area, the left ${\Delta}T$ of the group B showed below $0.2^{\circ}C$ or so in contrast to the right it. In the group C, on the both side showed continous increase of temperature as following times. 5. About Chich'ang($S_4$) area, the skin temperature increased valuable $0.3^{\circ}C$ or so on the both side and later inclined to decrease in the group B but not significantly. In the group C, it increased valuable on the both side. 6. The skin temperature of electroacupuncture treatment group B, C were more increase than the control group A except Lt. Yonghyang($LI_{20}$) area in the group B. The temperature of group C were more increase than the group B wholly. Conclusion : The above results indicate that D.I.T.I. is a useful method to observe and fallow-up the effects and the changes by electroacupuncture stimulation on objective evaluation of phenomenon for the meridian system and character. Thus, continuous thermographic study will be needed for more clinical application such as acupuncture and medicine or laser therapy according to oriental medicine.

  • PDF