• 제목/요약/키워드: Digital Radiography Test

Search Result 85, Processing Time 0.028 seconds

Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

The quantitative analysis by digital subtraction radiography on the effect of Enamel Matrix Protein and Platelet-Rich Plasma, combined with Xenograft in the treatment of intrabony defect in humans (골 내 결손 치료 시 법랑 기질 단백질과 이종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Han, Keum-Ah;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.961-974
    • /
    • 2005
  • Various biological approaches to the promotion of periodontal regeneration have been used. These can be divided into the use of growth and differentiation factors, application of extracellular matrix proteins and attachment factors and use of mediators of bone metabolism. The purpose of this study was to evaluate the effect of enamel matrix protein and platelet-rich plasma on the treatment of intrabony defect, with bovine-derived bone powder in humans by digital subtraction radiography. 12 teeth(experimental I group) were treated with enamel matrix protein combined with bovine-derived bone powder and 12 teeth(experimental II group) were treated with platelet-rich plasma combined with bovine-derived bone powder. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content was assessed in the method that two radiography were put into computer program to be overlapped and the previous image was subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program for windows(5% significance level). The results were as follows: 1. The radiolucency in 3 months after surgery was significantly increased than 1 month after surgery in both groups(experimental I and II groups)(p<0.05). 2. The radiopacity in 6 months after surgery was significantly increased than 3 months after surgery in both groups(experimental I and II groups) (p<0.05). 3. In experimental I group, there was no significant difference between 1 month and 6 months after surgery. 4. In experimental II group. the radiopacity in 6 months after surgery was significantly increased than 1 month after surgery(p<0.05). 5. There was no significant difference between experimental I and II group at 1 month and 3 months after surgery, but the radiopacity in experimental II group was significantly increased at 6 months after surgery(p<0.05). In conclusion, platelet-rich plasma can enhance bone density than enamel matrix protein until 6 months after surgery.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Computer-Aided Diagnosis for Pulmonary Tuberculosis using Texture Features Analysis in Digital Chest Radiography (질감분석을 이용한 폐결핵의 자동진단)

  • Kim, Dae-Hun;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.185-193
    • /
    • 2011
  • There is no exact standard of detecting pulmonary tuberculosis(TB) in digital image of simple chest radiography. In this study, I experimented on the principal components analysis(PCA) algorithm in the past and suggested six other parameters as identification of TB lesions. The purpose of this study was to develop and test computer aided diagnosis(detection) method for the detection and measurement of pulmonary abnormalities on digital chest radiography. It showed comparatively low recognition diagnosis rate using PCA method, however, six kinds of texture features parameters algorithm showed similar or higher diagnosis rates of pulmonary disease than that of the clinical radiologists. Proposed algorithms using computer-aided of texture analysis can distinguish between areas of abnormality in the chest digital images, differentiate lesions having pulmonary disease. The method could be useful tool for classifying and measuring chest lesions, it would play a major role in radiologist's diagnosis of disease so as to help in pre-reading diagnosis and prevention of pulmonary tuberculosis.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.