• Title/Summary/Keyword: Digester

Search Result 176, Processing Time 0.026 seconds

Effective Treatment of Swine Manure with Chinese Cabbage Silage through Two Serial Anaerobic Digestion (돈분과 배추사일리지를 이용한 2조 혐기소화의 효과적인 처리)

  • Kim, Sang-Hun;Kafle, Gopi Krishna
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.53-63
    • /
    • 2010
  • The performance of two serial completely stirred tank reactors (CSTRs) for treatment of swine manure (SM) with Chinese cabbage silage (CCS) was studied. The two CSTRs of 41 liters each were connected in series and first reactor was fed swine manure with Chinese cabbage silage in 3:1 proportion by VS basis. The FOS/TAC, methane content (%) and pH were utilized as the parameters for the digester stability control. The FOS/TAC value was found to be effective indicator for instant digester condition. The stability of reactors can be obtained with the FOS/TAC value up to 1.0 with accumulation of FOS value below 10,000 mg/L. Material exchange method was effective in transferring the excess volatile fatty acids (VFA) from the first reactor to the second one and maintaining stability in both the reactors. The biogas yield and the methane yield was 0.55-0.61 and 0.41-0.42 L/g VS fed, respectively, at organic loading rate (OLR) of 2.2-2.6 g VS/L with total HRT of 32 days.

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • v.5 no.2
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

A Study on Current Energy Consumption and Recycling at Public Wastewater Treatment Plants in Korea (국내 공공하수도 시설의 에너지 사용 및 자원화실태 조사연구)

  • Park, Seungho;Kim, Byongjoo;Bae, Jae-Ho;Lee, Cheol Mo;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.539-549
    • /
    • 2007
  • To establish effective and prompt measures for energy conservation in public wastewater treatment plants in Korea, energy consumption rates in 233 utilities in 9 provinces and 7 metropolitan cities are investigated and compared to the rest of the world. Mean load factor for wastewater treatment utilities is 74.9% and those for influent pumps and aeration blowers are 56.2% and 61.0%, respectively. Mean electrical energy usages as the key performance indicators are $0.243kWh/m^3$ for overall sewage treatments and 2.07 kWh per unit kg BOD removal. Digester gas as one of major byproducts in the process amounts to $382,000m^3/day$ nationwide. While major part of the digester gas is used for sludge heating, only 7.3% of the gas is utilized for electricity generation. Both efficiencies for BOD removal and digestion gas generation are considerably lower than those in USA and EU utilities due to low concentration of organic material in influent wastewater. Such low energy regeneration, in turn, results in significantly higher energy consumption in Korean plants, compared to that in USA and EU ones.

Effects of the Redox Potential of the Acidogenic Reactor on the Performance of a Two-Stage Methanogenic Reactor

  • Phae, Chae-Gun;Lee, Wan-Kyu;Kim, Byung-Hong;Koh, Jong-Ho;Kim, Sang-Won
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.1
    • /
    • pp.30-35
    • /
    • 1996
  • Distillery wastewater was used in a thermophilic laboratory-scale two stage anaerobic digester to test the effects of the redox potential of the first acidogenic reactor on the performance of the system. The digester consisted of first a acidogenic reactor and the an upflow anaerobic sludge blanket (UASB) reactor. The digestor was operated at a hydraulic retention time (HRT) of 48 h. Under these conditions, about 90% of the chemical oxygen demand as measured by the chromate method ($COD_{cr}$) was removed with a gas production yield of 0.4 l/g-COD removed. The redox potential of the acidogenic reactor was increased when the reactor was purged with nitrogen gas or agitation speed was increased. The increase in reduction potential was accompanied by an increase in acetate production and a decrease in butyrate formation. A similar trend was observed when a small amount of air was introduced into the acidogenic reactor. It is believed that the hydrogen partial pressure in the acidogenic reactor was decreased by the above mentioned treatments. The possible failure of anaerobic digestion processes due to over-loading could be avoided by the above mentioned treatments.

  • PDF

Effect of Temperature on Nitritation using Effluent of Anaerobic Digester (혐기 소화조 유출수의 아질산화 반응에 온도가 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.3
    • /
    • pp.286-292
    • /
    • 2011
  • Preparing for the Standards for Effluents which will be strengthen from 2012, many ways like remodellings and repairs of sewage treatment plant (STP) are considered. The treatment of the recycle water from the sludge treatment process contains high-strength organic compounds and nitrogen is considered as alternative. In the treatment of high-strength nitrogen, nitritation has more economic advantages than nitrification. In this study, lab-scale reactor was operated at the $35^{\circ}C$, $20^{\circ}C$ and $10^{\circ}C$ conditions using effluent of anaerobic digester to investigate the nitrogen removal by nitritation. Long-term stable nitritation was achieved at the $35^{\circ}C$, $20^{\circ}C$ but $10^{\circ}C$. In the stable nitritation states, nitrite conversion was higher at the high temperature of $35^{\circ}C$ than the room temperature of $20^{\circ}C$. Also shorter solid retention time (SRT) was needed to induce high nitrite conversion at the high temperature of $35^{\circ}C$. It was showed that temperature and SRT are important factors to induce nitritation.

Treatment of Organic Wastes and Reuse of Bio-energy from the Anaerobic Digestion - Thermophilic Oxic Precess (혐기성 소화-고온 호기법에 의한 유기성폐기물의 처리와 생성열의 재활용 검토)

  • Yang, Jae-Kyung;Choi, Kyung-Min
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.1
    • /
    • pp.79-89
    • /
    • 2001
  • Anaerobic Digestion - Thermophilic Oxic Process(ADTOP) has been known to be one way reducing and composting of organic wastes without draining or forming excess sludge. It could be completely performed by the evaporation of water using the bio-energy from the microbial degradation of organic. In the present study the complete treatment of Chinese restaurant wastes was conducted and utility of bio-energy produced from the ADTOP was estimated. Base on results, it could be concluded as follows; 1) chinese restaurant wastes could be completely treated using the TOP without draining or excess sludge. Maximum volumetric loading rate was determined as $55.0kg-garbage/m^3$. Input water was almostly evaporated and 90.5% of carboneous organic wastes was conversed to carbondioxide. 2)The optimum volumetric loading rate which is acceptable to maintain over $55^{\circ}C$ in the anaerobic digester was determined as $45kg-garbage/m^3{\cdot}d$. 3) The optimum HRT was at least over 10 days in order to maintain about $50^{\circ}C$ in the anaerobic digester using bio-energy produced from TOP. Therefore the utilization of bio-energy produced from TOP could be used in the process which had long HRT such as the anaerobic digestion. 4) The efficiency of anaerobic digester rate were over 90% by the ADTOP under the organic loading rate of $1.1kg-COD/m^3{\cdot}d$, 50kg-Chinese restaurant garbage and $250{\ell}/m^3{\cdot}min$ of the aeration rate.

  • PDF

Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste (순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가)

  • Park, Seyong;Kim, Moonil;Park, Seonghyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.3
    • /
    • pp.5-16
    • /
    • 2021
  • In this study, the applicability of the MBR(Membrane Bio Reactor) process of oxygen dissolve was evaluated through comparison and evaluation of the efficiency of oxygen dissolve device and conventional aeration device in the explosive tank within the MBR process. The organic matter and ammonia oxidation by oxygen dissolve device were evaluated, and the efficiency of persaturation was evaluated by applying real waste water (anaerobic digester effluent treatement from food waste). SCOD and ammonia removal rates for oxygen dissolve device and conventional aeration device methods were similar. However, it was determined that the excess sludge treatment cost could be reduced as the yield of microorganisms by oxygen dissolve device is about 0.03 g MLSS-produced/g SCOD-removed lower than that of microorganisms by conventional aeration device. The removal rates of high concentrations of organic matter (4,000 mg/L) and ammonia (1,400 mg/L) in anaerobic digester effluent treatment from food waste were compared to the conventional aeration device and the oxygen dissolve device organic matter removal rate was approximately 13% higher than that of the conventional aeration device. In addition, for MLSS, the conventional aeration device was 0.3 times higher than for oxygen dissolve device. This is believed to be due to the high progress of sludge autooxidation because the dissolved oxygen is sufficiently maintained and supplied in the explosive tank for oxygen dissolve device. Therefore, it was determined that the use of oxygen dissolve device will be more economical than conventional aeration device as a way to treat wastewater containing high concentrations of organic matter.

Anaerobic Digestion of Agricultural Wastes and 1ts Benefits (농산폐기물(農産廢棄物)의 메탄발효(醱酵)와 그 이점(利點))

  • Park, Young-Dae
    • Applied Biological Chemistry
    • /
    • v.27
    • /
    • pp.3-17
    • /
    • 1984
  • Anaerobic digestion has recently attracted all over the world and Korea also shows no exception. The major benefits of anaerobic digestion are energy production, water pollution control, pathogen reduction and effective manure production. In Korea it was recognized in late sixties that there was a positive need to find alternative energy for farmers household. The main traditional energy sources in rural area were crop residues and forestry products. Therefore Office of Rural Development through its Rural Guidance Bureau disseminated about 29,000 household biogas units from 1969 to 1975 to provide cooking fuel for farmers household and to improve the mode of farmers living standards. The units were welcomed by farmers at that time. Now, however, most of them are not using due to a number of reasons associated with cold winter and some techno-economical problems (in those day, fossil fuel was quite expensive to compare with other prices and since then farmers income was quickly increased). The author studied on bag type household biogas plant to solve some technical problems of existing household biogas plants, but this also has little appeal for the farmers. From 1977 author studied on village scale biogas plant with two pilot plants. From the viewpoint of energy production, COD removal, kill rate of pathogen and fertilizer value, the results obtained from the experiments were quite promising, but the construction cost of the village scale biogas plant was too high for the farmers in Korea. To find most suitable biogas plant for farmers in Korea through the simplifying the biogas digester, the author developed batch-load biogas plant. By feeding coarse crop residues and manures, total solids concentrations of the batch-load biogas plant are about 28 percent which is much higher than continous digester of 5-8 percent. The batch-load biogas plant was welcomed by many farmers in Korea when it was reported on TV and newspapers. The plant was disseminated 154 units in 1982, 766 units in 1983 and 812 units in 1984 as a promissing project. Besides these biogas plant experiments, studies were also conducted 1) to determine gas production rate with agricultural wastes, 2) to evaluate the effect of loading rate, dilution, retention time on biogas production, 3) to project the amount of potencial energy from agricultural wastes.

  • PDF

Feasibility Studies on Anaerobic Sequencing Batch Retractor for Sludge Treatment

  • Duk Chang;Joo
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.125-136
    • /
    • 1992
  • Digestion of a municipal wastewater sludge by the anaerobic sequencing batch reactor (ASBR) was investigated to evaluate the performance of the ASBR process at a critical condition of high-solids-content fined. The reactors were operated at an HRT of 10 days with an equivalent loading rate of 0.8-1.5 gVS/L/d at 35$^{\circ}C$ The main conclusions drawn from this study were as follows: 1. Digestion of a municipal wastewater sludge was possible using the ASBR in spite of high concentration of settleable solids in the sludge. The ASBRS with 3- and 4-day cycle period showed almost identical high digestion performances. 2. No adverse effect on digestion stability was observed In the ASBRS in spite of withdrawal and replenishment of 30% or 40% of liquid contents. A conventional anaerobic digester could be easily converted to the ASBR without any stability problem. 3. Flotation thickening occurred in thicken step of the ASBRS throughout steady state, and floating bed volume at the end of thicken period occupied about 70% of the working volume of the reactor Efficiency of flotation thickening in the ASBRS could be comparable to that of additional gravity thickening of a completely mixed digester. 4. Solids were accumulated rapidly in the ASBR during start-up period. Solids concentrations in the ASBRS were 2.6 times higher than that in the completely mixed control reactor at steady state. Dehydrogenase activity had a strong correlation with the solids concentration. Dehydrogenase activity of the digested flu형e in the ASBR was 2.9 times higher than that of the flu형e in the control reactor, and about 25 times higher than that of the subnatant in the ASBR. 5. Remarkable increase in equivalent gas production of 52% was observed at the ASBRS compared with the control reactor in spite of similar quality of clarified effluent from the ASBRS and control reactor. The increase in gas production from the ASBRS was believed to be combined results of accumulation of microorganisms, higher driving force applied, and additional long-term degradation of organics continuously accumulated.

  • PDF

A Study of the Improvement in an Anaerobic Digester for Sludge Reduction (슬러지 저감을 위한 혐기성 소화조 개선에 관한 연구)

  • Kim, Hong-Seok;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.516-522
    • /
    • 2011
  • The largest problem of domestic anaerobic digestion is low digestion efficiency. Reasons of the problem would be low organic matters input, low mixing efficiency in digestion tank, refractory excess sludge etc.. In this study, screw attached disk-type concentration system and a mechanical mixing system, solubilization facility improvements were performed to solve problems. Through these improvements, the sludge conc. of the concentrator increased 2.6-fold and the volume reduction efficiency was increased 3.0-fold. In addition, the dead-space is reduced by mechanical agitation. Anaerobic digester gas production in the digestion tank is increased from $193.8m^3$ to $386.0m^3$ per day. Digestion efficiency is improved to 54.6% from 47.6%. Digestion gas production is increased from $0.30Nm^3/kg$ VS to $0.42Nm^3/kg$ VS.