• 제목/요약/키워드: Diffusion weighted MRI

검색결과 166건 처리시간 0.024초

Vasogenic Edema in Experimental Cerebral Fat Embolism

  • Park Byung-Rae;Koo Bong-Oh
    • 대한의생명과학회지
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 2005
  • To evaluate the magnetic resonance imaging and electron microscopic findings of the hyperacute stage of cerebral fat embolism in cats and the time needed for the development of vasogenic edema. Magnetic resonance imaging was performed at 30 minutes (group 1, n=9) and at 30 minutes and 1, 2, 4, and 6 hours after embolization with triolein (group 2, n= 10). As a control for group 2, the same acquisition was obtained after embolization with polyvinyl alcohol particles (group 3, n=5). Electron microscopic examination was done in all cats. In group 1, the lesions were iso- or slightly hyperintense on T2-weighted (T2W) and diffusion-weighted (DWIs) images, hypointense on the apparent diffusion coefficient (ADC) map image, and markedly enhanced on the gadolinium-enhanced T1-weighted images (Gd-T1WIs). In group 2 at 30 minutes, the lesions were similar to those in group 1. Thereafter, the lesions became more hyperintense on T2WIs and DWIs and more hypoinfense on the ADC map image. In group 3, the lesions showed mild hyperintensity on T2WIs at 6 hours but hypointensity on the ADC map image from 30 minutes, with a tendency toward a greater decrease over time. Electron microscopic findings revealed discontinuity of the capillary endothelial wall, perivascular and interstitial edema, and swelling of glial and neuronal cells in groups 1 and 2. The lesions were hyperintense on T2WIs and DWIs, hypointense on the ADC map image, and enhanced on Gd-T1WIs. On electron microscopy, the lesions showed cytotoxic and vasogenic edema with disruption of the blood-brain barrier.

  • PDF

국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교 (Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system)

  • 박혜영;조현제;김은미;허감;김용훈;이병훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.22-31
    • /
    • 2011
  • 목적: 이 연구의 목적은 간 병변 발견에 있어 1.5-T 자기공명영상에서 자유 호흡 확산강조 영상과 호흡 유발 확산강조 영상의 유용성을 비교하는데 있다. 대상 및 방법: 47명의 환자(평균 57.9세, 남성:여성 = 25:22)가 한번의 간 자기공명 영상검사에서 자유호흡 확산 강조 영상과 호흡유발 확산 강조 영상을 동시에 시행하였다. 이를 두 명의 영상의학과 의사가 호흡유발 이미지 세트(B50, B400, B800 확산강조 영상과 ADC map)와 자유호흡 이미지 세트를 2주간의 시간 간격을 두고 무작위로 후향적 분석을 시행하였다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 간의 신호대 잡음비 (signal-to-noise ratio, SNR)와 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과: 32개의 낭종, 13개의 혈관종, 7개의 간세포암, 6국소 호산구성 간질환, 2개의 전이, 1개의 초점성 결절성 과증식과 글리슨막의 가성지방종을 포함하는 총 62개의 병변이 두 명의 평가자에 의하여 분석되었다. 비록 통계적 유의성을 없었으나, 전체적인 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [평가자 1:평가자 2, 47/62(75.81%):45/62(72.58%)] 자유호흡 확산강조 영상보다 [44/62(70.97%):41/62(66.13%)] 더 높은 수치를 보였다. 특히 1 cm보다 작은 국소 간 병변 발견의 sensitivity는 호흡유발 확산강조 영상이 [24/30(80%): 21/30(70%)] 지유호흡 확산강조 영상보다 [17/30(56.7%):15/30(50%)] 더 우월하였다. 진단적 정확도활 계산하기 위하여 ROC curve (Az value)를 구하였으며 자유호흡 확산강조 영상과 호흡유발 확산강조 영상간에는 통계적 차이는 없었다. 간의 신호대 잡음비 (SNR)와 대조도 (CNR)는 호흡유발 확산강조 영상이 ($87.6{\pm}41.4$, $41.2{\pm}62.5$) 자유호흡확산강조 영상보다 ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) 높았으며 통계적인 유의성이 있었다. (p value < 0.001). 결론: 1.5-T자기공명 시스템서 1 cm보다 작은 간 병변발견에 있어서 호흡유발 확산강조 영상이 자유호흡 확산강조 영상보다 좋으며 이는 호흡유발 확산강조 영상이 높은 신호대 잡음비 (SNR)와 대조도(CNR)를 보이기 때문이다.

An Updated Review of Magnetic Resonance Neurography for Plexus Imaging

  • Joon-Yong Jung;Yenpo Lin;John A Carrino
    • Korean Journal of Radiology
    • /
    • 제24권11호
    • /
    • pp.1114-1130
    • /
    • 2023
  • Magnetic resonance neurography (MRN) is increasingly used to visualize peripheral nerves in vivo. However, the implementation and interpretation of MRN in the brachial and lumbosacral plexi are challenging because of the anatomical complexity and technical limitations. The purpose of this article was to review the clinical context of MRN, describe advanced magnetic resonance (MR) techniques for plexus imaging, and list the general categories of utility of MRN with pertinent imaging examples. The selection and optimization of MR sequences are centered on the homogeneous suppression of fat and blood vessels while enhancing the visibility of the plexus and its branches. Standard 2D fast spin-echo sequences are essential to assess morphology and signal intensity of nerves. Moreover, nerve-selective 3D isotropic images allow improved visualization of nerves and multiplanar reconstruction along their course. Diffusion-weighted and diffusion-tensor images offer microscopic and functional insights into peripheral nerves. The interpretation of MRN in the brachial and lumbosacral plexi should be based on a thorough understanding of their anatomy and pathophysiology. Anatomical landmarks assist in identifying brachial and lumbosacral plexus components of interest. Thus, understanding the varying patterns of nerve abnormalities facilitates the interpretation of aberrant findings.

유방의 유두상 병변의 진단에서 자기공명영상의 역할 (Role of MRI in Diagnostic Evaluation of Papillary Lesions of the Breast)

  • 이소미;김혜정;곽연주;이희중;장윤진;신경민;박지영;정진향
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.41-46
    • /
    • 2010
  • 목적 : 유방의 유두상 병변의 진단에 있어 자기공명영상의 역할에 대해 알아보고자 한다. 대상 및 방법 : 초음파 유도하 핵생검에서 양성 유두상 병변으로 진단된 45예 중 자기공명영상을 시행한 22명의 환자 27예를 대상으로 하였다. 자기공명영상 시행 1-10일 후 절제 생검을 시행하였다. 자기공명영상 소견은 형태학적 기준에서 불규칙하거나 환형 또는 선형 조영증강을 보이거나 조영증강 양상에서 지연기 조영유실을 보이는 경우를 의심스러운 병변으로 분류하였다. 확산강조영상에서 병변의 발견 여부도 알아보았다. 자기공명영상 소견이 절제 생검 결과와 관련이 있는지 알아보았다. 결과 : 핵생검에서 비정형성이 없는 22예의 양성 유두상 병변 중 2예(9%), 비정형성이 있는 5예의 양성 유두상 병변 중 4예(80%)가 절제 생검에서 악성으로 진단되었다. 자기공명영상에서 발견된 18예 중 16예에서 암이 의심되는 소견을 보였으며, 절제 생검에서 양성이 11예(69%), 악성이 5예(31%)였다. 확산강조영상에서 보이는 12예 중 10예가 양성, 2예가 악성으로 진단되었다. 자기공명영상 소견은 절제 생검 결과와 상관이 없었다. 결론 : 핵생검에서 진단된 양성 유두상 병변의 자기공명영상 소견은 대부분(88.9%, 16/18)에서 암이 의심되는 소견을 보여 악성 예측에 도움이 되지 않았으며 자기공명영상에서 위양성 소견을 보이는 병변에 양성 유두상 병변이 포함되어야 할 것이다.

척수경색의 확산강조자기공명영상 (Diffus ion-Weighted MR Imaging of Spinal Cord Infarction)

  • 김윤정;서정진;임남열;정태웅;김윤현;박진균;정광우;강형근
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권2호
    • /
    • pp.166-172
    • /
    • 2002
  • 목적: 척수경색의 진단에서 현성확산계수 값의 측정을 포함한 확산강조자기공명영상의 유용성을 평가하고자하였다. 대상 및 방법: 척수 경색으로 진단받은 6명의 환자를 대상으로 후향적으로 분석하였다. 경색증상 발현 후 평균 5.4일이 지난 후에 1.5 T 초전도체 자기공명영상 기기를 이용하여 자기공명영상을 얻었다. 확산강조자기공명영상은 고식적인 b값($1000s/\textrm{mm}^2$)으로 하여 multi-shot echo planar imaging 기법을 이용하여 영상을 획득하였으며 개인용 컴퓨터로 옮겨져 현성확산계수 지도를 얻어 정상부위와 병변부위의 현성확산계수 값을 측정하였다. 자기공명영상에서 병변의 위치와 T1 과 T2 강조영상, 그리고 확산강조자기공명영상에서 나타나는 각각의 신호강도를 알아 보았고, 병변부위와 정상부위에서 측정한 현성확산계수 값을 비교하였다. 결과: T1강조영상에서 6예 중 4예에서 등신호강도를, 2예에서 저신호 강도를 보였고, T2강조 영상에서 6예 모두 고신호강도를 보였다. 또한 확산강조자기공명영상에서 6예 모두 고신호강도를 보였다. 현성확산계수 지도는 6예 전예에서 성공적으로 얻을 수 있었다. 현성확산계수 지도에서 6예 모두 정상과 뚜렷한 차이를 보이는 색조변화를 보였으며, 6예 모두 병변부위의 현성확산계수 값은 정상 부위의 현성확산계수의 값보다 더 낮았으며 통계적으로 유의하였다 (p<0.05 ). 결론: 척수경색 환자에서 척수병변의 확산강조자기공명영상과 현성확산계수 값의 측정이 가능하였다. 따라서 확산강조자기공명영상은 척수경색의 조기진단과 국재화(localization)에 유용하리라 보여진다.

  • PDF

Interpretation of Complete Tumor Response on MRI Following Chemoradiotherapy of Rectal Cancer: Inter-Reader Agreement and Associated Factors in Multi-Center Clinical Practice

  • Hae Young Kim;Seung Hyun Cho;Jong Keon Jang;Bohyun Kim;Chul-min Lee;Joon Seok Lim;Sung Kyoung Moon;Soon Nam Oh;Nieun Seo;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • 제25권4호
    • /
    • pp.351-362
    • /
    • 2024
  • Objective: To measure inter-reader agreement and identify associated factors in interpreting complete response (CR) on magnetic resonance imaging (MRI) following chemoradiotherapy (CRT) for rectal cancer. Materials and Methods: This retrospective study involved 10 readers from seven hospitals with experience of 80-10210 cases, and 149 patients who underwent surgery after CRT for rectal cancer. Using MRI-based tumor regression grading (mrTRG) and methods employed in daily practice, the readers independently assessed mrTRG, CR on T2-weighted images (T2WI) denoted as mrCRT2W, and CR on all images including diffusion-weighted images (DWI) denoted as mrCRoverall. The readers described their interpretation patterns and how they utilized DWI. Inter-reader agreement was measured using multi-rater kappa, and associated factors were analyzed using multivariable regression. Correlation between sensitivity and specificity of each reader was analyzed using Spearman coefficient. Results: The mrCRT2W and mrCRoverall rates varied widely among the readers, ranging 18.8%-40.3% and 18.1%-34.9%, respectively. Nine readers used DWI as a supplement sequence, which modified interpretations on T2WI in 2.7% of cases (36/1341 [149 patients × 9 readers]) and mostly (33/36) changed mrCRT2W to non-mrCRoverall. The kappa values for mrTRG, mrCRT2W, and mrCRoverall were 0.56 (95% confidence interval: 0.49, 0.62), 0.55 (0.52, 0.57), and 0.54 (0.51, 0.57), respectively. No use of rectal gel, larger initial tumor size, and higher initial cT stage exhibited significant association with a higher interreader agreement for assessing mrCRoverall (P ≤ 0.042). Strong negative correlations were observed between the sensitivity and specificity of individual readers (coefficient, -0.718 to -0.963; P ≤ 0.019). Conclusion: Inter-reader agreement was moderate for assessing CR on post-CRT MRI. Readers' varying standards on MRI interpretation (i.e., threshold effect), along with the use of rectal gel, initial tumor size, and initial cT stage, were significant factors associated with inter-reader agreement.

초기 간암 선별 검사로서 단축 자기공명영상 검사의 진단능: 고식적 역동학적 자기공명영상검사와의 비교 (Diagnostic Performance of Simulated Abbreviated MRI for Early-Stage Hepatocellular Carcinoma Screening: A Comparison to Conventional Dynamic Contrast-Enhanced MRI)

  • 임은솔;김성모;신상수;허숙희;이종은;정용연
    • 대한영상의학회지
    • /
    • 제82권5호
    • /
    • pp.1218-1230
    • /
    • 2021
  • 목적 고위험 환자에서 초기 간암 선별 검사로써 단축 자기공명영상 검사의 환자별 진단능을 기존의 고식적 간 자기공명영상검사와 비교하고자 한다. 대상과 방법 간암 고위험군에서 간 자기공명영상 검사를 시행 받은 총 201명의 환자에 대해 연구를 시행하였다. 단축 자기공명영상 검사 군의 프로토콜은 T2 강조영상, 담도기 T1 강조영상, 확산강조영상 등으로 구성되며, 두 명의 영상의학과 의사가 각각의 환자에 대해 후향적으로 단축 자기공명영상검사 군 및 고식적 자기공명영상검사 군, 두 군의 영상을 독립적으로 평가하였다. 두 연구자 간 일관성은 Cohen's kappa 값을 이용하여 비교하였다. 복합적인 참조표준을 이용하여 두 군에서 각각 진단능을 평가하여 비교하였다. 결과 79 명의 환자에서 총 93개의 간암이 발견되었다. 두 연구자 간 일관성은 두 군에서 모두 매우 양호하였다(κ = 0.839, 0.948). 단축 자기공명영상검사 군에서 민감도 및 음성예측도는 각각 94.9% 및 96.4%였으며, 이는 고식적 자기공명영상검사 군과 큰 차이를 보이지 않았다(96.2%, 97.5%). 결론 단축 자기공명영상검사는 고식적 자기공명영상검사에 비교하여 임상적으로 허용 가능한 민감도와 음성예측도를 갖는다. 따라서 간암 고위험군 환자에서 간암 선별검사로써 새로운 대안이 될 수 있을 것이다.

Measurement of Apparent Diffusion Coefficient Values from Diffusion-Weighted MRI: A Comparison of Manual and Semiautomatic Segmentation Methods

  • Kim, Seong Ho;Choi, Seung Hong;Yoon, Tae Jin;Kim, Tae Min;Lee, Se-Hoon;Park, Chul-Kee;Kim, Ji-Hoon;Sohn, Chul-Ho;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.88-98
    • /
    • 2015
  • Purpose: To compare the interobserver and intraobserver reliability of mean apparent diffusion coefficient (ADC) values using contrast-enhanced (CE) T1 weighted image (WI) and T2WI as structural images between manual and semiautomatic segmentation methods. Materials and Methods: Between January 2011 and May 2013, 28 patients who underwent brain MR with diffusion weighted image (DWI) and were pathologically confirmed as having glioblastoma participated in our study. The ADC values were measured twice in manual and semiautomatic segmentation methods using CE-T1WI and T2WI as structural images to obtain interobserver and intraobserver reliability. Moreover, intraobserver reliabilities of the different segmentation methods were assessed after subgrouping of the patients based on the MR findings. Results: Interobserver and intraobserver reliabilities were high in both manual and semiautomatic segmentation methods on CE-T1WI-based evaluation, while interobserver reliability on T2WI-based evaluation was not high enough to be used in a clinical context. The intraobserver reliability was particularly lower with the T2WI-based semiautomatic segmentation method in the subgroups with involved $lobes{\leq}2$, with partially demarcated tumor borders, poorly demarcated inner margins of the necrotic portion, and with perilesional edema. Conclusion: Both the manual and semiautomatic segmentation methods on CE-T1WI-based evaluation were clinically acceptable in the measurement of mean ADC values with high interobserver and intraobserver reliabilities.

B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성 (Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers)

  • 이재승;구은회;이선엽;박철수;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.683-690
    • /
    • 2009
  • 본 연구의 목적은 직장암 국소병변의 수술 전 검출을 위한 고 확산경사계수(High-b-values) 자기공명영상의 유용성을 평가하고자 한다. 직장암의 진단을 위하여 확산강조 자기공명영상을 시행한 60명의 환자 중 연령분포는 38 - 78세(평균 60세)였고 남자 40명, 여자가 20명 이었다. 사용된 장비는 1.5 Tesla 자기공명 영상기기(GE, General Electric Medical System, Excite HD)로 사용하였고, 검사 프로토콜은 고속기법 T2, T1강조영상을 얻은 후 정확한 병변 검출을 위하여 같은 위치를 정하여 확산강조영상을 얻었다. 확산강조영상의 b-value$(s/mm^2)$값은 250, 500, 750, 1000, 1500, 2000까지 변화시키면서 얻었다. 영상평가는 정량적 분석방법으로 직장, 방광과 종양간 대조도대 잡음비(rectum, bladder to tumor contrast noise ratio, 이하 CNR)를 GE software Functool tool을 사용하여 비교분석 하였고. 정성적 분석방법은 영상내의 인공물의 유무, 병변의 명확성, 직장벽 구분을 기준으로 네 명의 경험 있는 영상의학과 의사와 세 명의 방사선사가 영상을 분석하였다. 영상의 유의성 평가는 각 b-values 값에 대하여 ANOVA 검증과 Freedman 검증을 이용하여 분석하였다(p<0.05). 정량적 분석결과는 b-values 값 중 1000에서 직장, 종양의 평균 대조도대잡음비는 27.21, 24.44로 가장 높았고(p<0.05), 이때 확산계수는 $0.73\times10^{-3}$이었다. 정성적 분석결과로서, 병변의 명확성과 직장벽 구분은 $4.0\pm0.14$, $4.4\pm0.16$로 1000 값에서 가장 높았으며, 인공물유무는 $4.8\pm0.25$로 2000 값에서 높은 결과 이었다(p<0.05). 결론적으로, 확산강조영상은 수술 전 직장암 환자의 병변 검출에 유용성 있는 정보를 제공해 주었으며, 정확한 종괴의 발견을 위해는 고 확산경사계수 값 1000 영상이 가장 우수한 확산경사계수 값 이었다.

Primary Diffuse Large B-Cell Lymphoma of the Seminal Vesicle: a Case Report

  • Kwag, Kyung Su;Jang, Suk Ki;Yeon, Jae Woo;Kwon, Kye-Won;Son, Jeong Hwan;Kim, Hyuk Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.259-263
    • /
    • 2016
  • Primary diffuse large B-cell lymphoma of the seminal vesicle is an extremely rare disorder, with only two cases reported in the English literature. Here, we present imaging findings of a case of primary diffuse large B-cell lymphoma of the seminal vesicle. On transrectal ultrasonography, the mass presented as a 3.0-cm-sized heterogeneous, hypoechoic lesion in the right seminal vesicle. Computed tomography (CT) revealed a mass with rim-like enhancement in the right seminal vesicle. On magnetic resonance imaging (MRI), the tumor showed iso-signal intensity on T1-weighted images and heterogeneously intermediate-high signal intensity on T2-weighted images. The tumor showed rim-like and progressive enhancement with non-enhancing portion on dynamic scanning. Diffusion restriction was observed in the mass. On fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) imaging, a high standardized uptake value (maxSUV, 23.5) by the tumor was noted exclusively in the right seminal vesicle.