• Title/Summary/Keyword: Diffusion weighted MRI

Search Result 166, Processing Time 0.025 seconds

Pancreatic Paraganglioma: a Case Report and Literature Review

  • Park, Joon Suk;Min, Seon Jeong;Min, Soo Kee;Choi, Jung-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Paraganglioma is a rare tumor of paraganglia, derived from neural crest cells in sympathetic or parasympathetic ganglions. It can be widely distributed from the skull base to the bottom of the pelvis. The pancreas, however, is a rare location of this neoplasm, and only a limited number of cases have been reported in the English literature, especially with gadoxetic-acid-enhanced magnetic resonance imaging (MRI) and diffusion-weighted images (DWI). We herein report a case of pathologically proven paraganglioma in the pancreas head with a literature review on endoscopic ultrasonography (EUS), computed tomography (CT), gadoxetic-acid-enhanced MRI, and DWI sequence.

Unenhanced Breast MRI With Diffusion-Weighted Imaging for Breast Cancer Detection: Effects of Training on Performance and Agreement of Subspecialty Radiologists

  • Yeon Soo Kim;Su Hyun Lee;Soo-Yeon Kim;Eun Sil Kim;Ah Reum Park;Jung Min Chang;Vivian Youngjean Park;Jung Hyun Yoon;Bong Joo Kang;Bo La Yun;Tae Hee Kim;Eun Sook Ko;A Jung Chu;Jin You Kim;Inyoung Youn;Eun Young Chae;Woo Jung Choi;Hee Jeong Kim;Soo Hee Kang;Su Min Ha;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.11-23
    • /
    • 2024
  • Objective: To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). Materials and Methods: A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive. The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). Results: Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4-79.9), 90.8% (95% CI: 85.6-94.2), and 83.5% (95% CI: 78.6-87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8-97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9-89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1-79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52-0.63) before training and 0.68 (95% CI: 0.62-0.74) after training, with a difference of 0.11 (95% CI: 0.02-0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69-0.74) before training and 0.79 (95% CI: 0.76-0.80) after training (P = 0.002). Conclusion: Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.

The Usefulness of Diffusion-weighted MR Imaging for Differentiation between Degenerative Spines and Infectious Spondylitis (퇴행성 척추와 감염성 척추염의 감별에 있어서 확산강조영상의 유용성)

  • 박원규;변우목;최준혁
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.152-157
    • /
    • 2002
  • Purpose : The differential diagnosis between Modic type I degenerative spine and infectious spondylitis sometimes is difficult, because the affected bone marrows in both disease show similar signal intensity on conventional MR imaging. We evaluate the usefulness of diffusion-wighted MR imaging for differential diagnosis between Modic type I degenerative spine and infectious spondylitis. Materials and methods : The spin-echo and diffusion-weighted MR images of eight patients with Modic type I degenerative spines and 14 patients with infectious spondylitis diagnosed by clinical findings or CT-guided biopsies we re analyzed. The diffusion-weighted imaging sequence was based on reversed fast imaging with steady-state precession (PSIF). Signal intensity changes of the vertebral bone marrow on conventional spin-echo and diffusion-weighted MR imaging were compared between degenerative spine and infectious spondylitis. Results : On T1-weighte d images, the affeted bone marrow in both disease showed hypointense signals. On T 2-weighted images, all of type I degenerative spine and 11 of infectious spondylitis showed hyperintensity, and three of infectious spondylitis showed heterogeneo us mixed signal intensity. On diffusion-weighted MR images, all of type I degenerative spine were hypointense with peripheral high signal intensity to normal vertebral body, but infectious spondylitis was hyperintense (n = 11) and hypointense (n=3). Conclusion : Diffusion-weighted MR imaging is useful to differentiate Modic type I degenerative spine from infectious spondylitis. On diffusion-weighted images, the high singal intensity of bone marrow suggests infectious spondylitis, whereas the low signal intensity of bone marrow with peripheral focal high signal intensity suggests type I degenerative spine.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.

The Study on Signal to Noise Ratio of Single-Shot Turbo Spin Echo to Reduce Image Distortion in Brain Stem Diffusion MRI (뇌줄기 확산강조 자기공명영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 연구)

  • Koo, Nohyun;Lee, Hobeom;Choi, Kwanwoo;Son, Soonyong;Yoo, Beonggyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.241-246
    • /
    • 2016
  • The purpose of this study was to investigate the problems of low signal-to-noise ratio(SNR) of single-shot turbo spin echo(SS-TSE) by quantifying numerically decreased signal to noise ratio. Thirty five patients without brain disease underwent diffusion MRI in 3T scanner from July to October in 2015. Single shot echo planar imaging(SS-EPI) which is conventionally used in MRI was taken to compared SS-TSE in SNR of medulla oblongata. As a result, SNR of SS-TSE diffusion(b0=$314.41{\pm}42.96$, b1000=$117.33{\pm}14.04$) is than SS-EPI diffusion(b0=$514.84{\pm}48.97$, b=$208.65{\pm}25.70$) lower in b=0 image(38.9%) and b=1,000 image(43.8%). Thus, diffusion MR using SS-EPI of MS-EPI should be taken for diagnosis of disease in brain stem due to decreased SNR of diffusion using SS-TSE.

Diffusion-Weighted MR Neurography with Unidirectional Motion-Probing Gradient to Evaluate Lumbar Nerve Roots at 1.5T MR (요추 신경근 평가를 위한 1.5T MR의 단일 방향 경사자장을 사용한 확산강조 자기공명신경조영)

  • Na Yeon Yoon;Doo Hoe Ha;Sang Min Lee;Hye Jung Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.607-617
    • /
    • 2024
  • Purpose Recent studies have demonstrated the usefulness of diffusion-weighted MR neurography (DW MRN) for assessing nerve roots. This study aimed to evaluate the utility of DW MRN with a unidirectional motion-probing gradient (MPG) for the lumbar nerve roots at 1.5T MR. Materials and Methods Sixty-four lumbar spine MRI scans with DW MRN using anteroposterior unidirectional MPG were retrospectively analyzed. Any changes in the 512 lumbar spinal nerve roots from L3 to S1 were evaluated using T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE T1WI), and DW MRN, with agreement and correlation analysis. Results T2WI revealed compression of 78 nerve roots, and CE T1WI revealed 52 instances of nerve root enhancement. Sixty-seven nerve roots showed swelling and hyperintensity on DW MRN. A total of 42 nerve roots showed changes in the CE T1WI and DW MRN sequences. Moderate to substantial agreement and moderate positive correlation were observed between DW MRN and CE T1WI, as well as DW MRN and T2WI (κ = 0.59-0.65, ρ = 0.600-0.653). Conclusion DW MRN with unidirectional anteroposterior MPG can help evaluate neuritisrelated changes in spinal nerve roots and could serve as a sequence capable of complementing or substituting gadolinium CE imaging.

Methanol-Induced Encephalopathy: a Case Report

  • Kim, Hyun Jin;Sunwoo, Moon Kyung;Lee, Jang Han;Choi, Yong Sun;Kim, Dae Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.61-64
    • /
    • 2017
  • A characteristic imaging finding in cases of methanol intoxication is putaminal necrosis, but its presence is usually not suspected due to its rarity. Methanol intoxication generally produces serious neurological symptoms that include visual disturbances and diminished consciousness, characteristically with metabolic acidosis. We reported the case of a 59-year-old man who was admitted to the hospital with diminished consciousness. Acute methanol intoxication was determined as the cause. Laboratory tests revealed high anion gap metabolic acidosis. Diffusion-weighted MRI indicated diffuse symmetric diffusion restriction lesions in the subcortical white matter of both cerebral hemispheres.

Tumor-like Presentation of Tubercular Brain Abscess: Case Report

  • Karki, Dan B.;Gurung, Ghanashyam;Sharma, Mohan R.;Shrestha, Ram K.;Sayami, Gita;Sedain, Gopal;Shrestha, Amina;Ghimire, Ram K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.231-236
    • /
    • 2015
  • A 17-year-old girl presented with complaints of headache and decreasing vision of one month's duration, without any history of fever, weight loss, or any evidence of an immuno-compromised state. Her neurological examination was normal, except for papilledema. Laboratory investigations were within normal limits, except for a slightly increased Erythrocyte Sedimentation Rate (ESR). Non-contrast computerized tomography of her head revealed complex mass in left frontal lobe with a concentric, slightly hyperdense, thickened wall, and moderate perilesional edema with mass effect. Differential diagnoses considered in this case were pilocytic astrocytoma, metastasis and abscess. Magnetic resonance imaging (MRI) obtained in 3.0 Tesla (3.0T) scanner revealed a lobulated outline cystic mass in the left frontal lobe with two concentric layers of T2 hypointense wall, with T2 hyperintensity between the concentric ring. Moderate perilesional edema and mass effect were seen. Post gadolinium study showed a markedly enhancing irregular wall with some enhancing nodular solid component. No restricted diffusion was seen in this mass in diffusion weighted imaging (DWI). Magnetic resonance spectroscopy (MRS) showed increased lactate and lipid peaks in the central part of this mass, although some areas at the wall and perilesional T2 hyperintensity showed an increased choline peak without significant decrease in N-acetylaspartate (NAA) level. Arterial spin labelling (ASL) and dynamic susceptibility contrast (DSC) enhanced perfusion study showed decrease in relative cerebral blood volume at this region. These features in MRI were suggestive of brain abscess. The patient underwent craniotomy with excision of a grayish nodular lesion. Abundant acid fast bacilli (AFB) in acid fast staining, and epithelioid cell granulomas, caseation necrosis and Langhans giant cells in histopathology, were conclusive of tubercular abscess. Tubercular brain abscess is a rare manifestation that simulates malignancy and cause diagnostic dilemma. MRI along with MRS and magnetic resonance perfusion studies, are powerful tools to differentiate lesions in such equivocal cases.

Quantitative, qualitative Evaluation of Diffusion-Weighted MRI using Optimal b-value(s/mm2) for Female Pelvis (여성골반에 대한 최적의 b-value(s/mm2)를 이용한 확산강조 자기공명영상의 정량적, 성적 평가)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.361-368
    • /
    • 2013
  • The purpose of this study is to know the clinical usefulness of optimal b-values by quantitative, qualitative evaluation of DW-MRI for lesions of benignity and malignity of female pelvis. The b-values used in DWI were 600, 800, 1000, 1200, 1400($s/mm^2$). Mean SNR and CNR of myoma in b-value 800 were the highest result as $84.6{\pm}4.57$(p=0.024) and $50.13{\pm}5.47$(p=0.028), Mean SNR and CNR of cervical cancer were the highest result as $12.0{\pm}2.04$(p=0.047) and $10.6{\pm}1.24$(p=0.001), Mean ADC value in myoma and cervical cancer in b-value 800 were $1.19{\times}10^{-3}mm^2/s$(p=0.008), $0.96{\times}10^{-3}mm^2/s$(p=0.027). As a qualitative analysis, the delineation and conspicuity were the highest result as $4.02{\pm}0.18$(p=0.028), $4.39{\pm}0.25$(p=0.015) on b-value 800. DW-MRI is an important method, and the optimal b values is 800 $s/mm^2$ for differentiation between benign and malignant lesions of female pelvis.

Why Is a b-value Range of 1500-2000 s/mm2 Optimal for Evaluating Prostatic Index Lesions on Synthetic Diffusion-Weighted Imaging?

  • So Yeon Cha;EunJu Kim;Sung Yoon Park
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.922-930
    • /
    • 2021
  • Objective: It is uncertain why a b-value range of 1500-2000 s/mm2 is optimal. This study was aimed at qualitatively and quantitatively analyzing the optimal b-value range of synthetic diffusion-weighted imaging (sDWI) for evaluating prostatic index lesions. Materials and Methods: This retrospective study included 92 patients who underwent DWI and targeted biopsy for magnetic resonance imaging (MRI)-suggested index lesions. We generated sDWI at a b-value range of 1000-3000 s/mm2 using dedicated software and true DWI data at b-values of 0, 100, and 1000 s/mm2. We hypothesized that lesion conspicuity would be best when the background (i.e., MRI-suggested benign prostatic [bP] and periprostatic [pP] regions) signal intensity (SI) is suppressed and becomes homogeneous. To prove this hypothesis, we performed both qualitative and quantitative analyses. For qualitative analysis, two independent readers analyzed the b-value showing the best visual conspicuity of an MRI-suggested index lesion. For quantitative analysis, the readers assessed the b-value showing the same bP and pP region SI. The 95% confidence interval (CI) or interquartile range of qualitatively and quantitatively selected optimal b-values was assessed, and the mean difference between qualitatively and quantitatively selected b-values was investigated. Results: The 95% CIs of optimal b-values from qualitative and quantitative analyses were 1761-1805 s/mm2 and 1640-1771 s/mm2 (median, 1790 s/mm2 vs. 1705 s/mm2; p = 0.003) for reader 1, and 1835-1895 s/mm2 and 1705-1841 s/mm2 (median, 1872 s/mm2 vs. 1763 s/mm2; p = 0.022) for reader 2, respectively. Interquartile ranges of qualitatively and quantitatively selected optimal b-values were 1735-1873 s/mm2 and 1573-1867 s/mm2 for reader 1, and 1775-1945 s/mm2 and 1591-1955 s/mm2 for reader 2, respectively. Bland-Altman plots consistently demonstrated a mean difference of less than 100 s/mm2 between qualitatively and quantitatively selected optimal b-values. Conclusion: b-value range showing a homogeneous background signal may be optimal for evaluating prostatic index lesions on sDWI. Our qualitative and quantitative data consistently recommend b-values of 1500-2000 s/mm2.