• 제목/요약/키워드: Diffraction attenuation

검색결과 41건 처리시간 0.026초

TV용 탄성표면파 필터의 개발 I-설계방법의 비교 및 제작방법 (Development of TV-IF SAW Filter I-Comparison of the Design Methods and Fabrication)

  • 김진하;남정현
    • 대한전자공학회논문지
    • /
    • 제21권5호
    • /
    • pp.17-26
    • /
    • 1984
  • 본 논문은 탄성표면파를 이용한 소형 TV중간주파 필터의 설계 및 제작과정을 보고한다. 초기의 원하는 임펄스응답을 얻기 위해 윈도우잉 (windowing) 방법 및 주파수 샘플링 방법이 제안되어 시간축샘플링 방법과 비교 연구되었으며, 트랩부근에서 원하는 특성을 얻기 위해 회절영향이 보상되었다. 다중 반사를 줄이고 비대칭 특성을 얻기 위해 4f0샘플링 기법을 사용하였으며, 효과적인 사진부식 방법을 사용하여 11.2㎛의 폭을 갖는 양호한 핑거가 얻어겼다. 본 연구는 SAW 필터의 국산화라는 차원에서. 요구하는 사양을 만족시킬 수 있고, 양산성이 있는 크기를 가진 제품을 개발하였음을 보고한다.

  • PDF

Effects of Drying Temperature on the Optical Properties of Solution Derived (Pb, La)$TiO_3$ Thin Films

  • Yoon, Dae-Sung;Kim, Sung-Wuk;Koo, Jun-Mo;Jiang, Zhong-Tao
    • The Korean Journal of Ceramics
    • /
    • 제1권4호
    • /
    • pp.191-196
    • /
    • 1995
  • Using sol-gel processing method, thin films of lathanum modified lead titanate(PLT) on Corning 7059 glass were prepared. A differential thermal analysis (DTA/TG) curve of gel powder and infrared spectra (FT-IR) of the films were measured to estimate residual organices in them. The heat-treated films were characterized by X-ray diffraction(XRD). Microstructures of the films were observed by a scanning electron microscope (SEM). Optical properties of the films were determined by a UV-VIS spectrophotometer. The waveguiding properties and optical attenuation were measured with the end coupling method and the cut back method. Effects of the drying conditions on the transmittance and the propagation loss of the films were investigated. Experimemtal results showed that the content of residual organics in the film decreased as the drying temperature of the film increased. As the La content of the film increased, the grain size decreased and the transmittance increased. The transmittances of the films increased with the increasing of the drying temperature. The propagation losses in the film decreased as the drying temperature increased.

  • PDF

도심지 재개발사업 환경영향평가시 소음지도 적용방안에 관한 연구 (Utilizing Noise Mapping in Environmental Impact Assessment in a Downtown Redevelopment Area)

  • 이시원;박영민;최진권;장서일
    • 한국소음진동공학회논문집
    • /
    • 제15권11호
    • /
    • pp.1311-1317
    • /
    • 2005
  • In environmental Impact assessment, noise impact assessment usually consists of three stages-surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of a project. The distance-attenuation relation of a point source, which has been used to predict the noise level due to its simplicity does not consider complex acoustic phenomena like multi-reflection, -diffraction and -absorption due to complex topographic configuration of buildings and terrains. For the consideration of such physical complexities. a noise mapping tool is adopted to produce a series of noise maps, which are those for the present, tot the works of construction and for the future. For accurate noise mapping, acoustical and topographic Information is used. Standard sound power levels and directivities of various construction equipments are need and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.

Impacts of the calcination temperature on the structural and radiation shielding properties of the NASICON compound synthesized from zircon minerals

  • Islam G. Alhindawy;Hany Gamal;Aljawhara.H. Almuqrin;M.I. Sayyed;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1885-1891
    • /
    • 2023
  • The present work aims to fabricate Na1+xZr2SixP3-xO12 compound at various calcination temperatures based on the zircon mineral. The fabricated compound was calcinated at 250, 500, and 1000℃. The effect of calcination temperature on the structure, crystal phase, and radiation shielding properties was studied for the fabricated compound. The X-ray diffraction diffractometer demonstrates that, the monoclinic crystal phase appeared at a calcination temperature of 250℃ and 500℃ is totally transformed to a high-symmetry hexagonal crystal phase under a calcination temperature of 1000℃. The radiation shielding capacity was also qualified for the fabricated compounds using the Monte Carlo N-Particle transport code in the g-photons energy interval between 15keV and 122keV. The impacts of calcination temperature on the g-ray shielding behavior were clarified in the present study, where the linear attenuation coefficient was enhanced by 218% at energy of 122keV, when the calcination temperature increased from 250 to 1000℃, respectively.

유기점토를 이용한 유기염소계 농약(2,4-D, atrazine) 오염 저감 (Attenuation of Chlorinated Pesticides(2,4-D, atrazine) Using Organoclays)

  • 최지연;신원식
    • 한국환경과학회지
    • /
    • 제20권2호
    • /
    • pp.185-197
    • /
    • 2011
  • Sorption of chlorinated pesticides such as 2,4-dichlorophenoxyacetic acid (2,4-D) and atrazine onto natural clays (montmorillonite and zeolite) modified with cationic surfactant, hexadecyltrimethyl-ammonium (HDTMA) and a natural soil was investigated using batch adsorbers. The clays were transformed from hydrophilic to hydrophobic by the cation exchange between clay surface and HDTMA up to 100% of the cation exchange capacity (CEC). Physicochemical characteristics of the sorbents such as pH, PZC (point of zero charge), organic carbon content ($f_{oc}$), fourier transform infrared spectroscopy (FT-IR), differential thermogravimetric analysis (DTGA) and X-ray diffraction (XRD) were analyzed. Sorption isotherm models such as Freundlich and Langmuir were fitted to the experimental data, resulting Langmuir model ($R^2$ > 0.986) was fitted better than Freundlich model ($R^2$ > 0.973). Sorption capacity ($Q^0$) for 2,4-D and atrazine was in the order of HDTMA-montmorillonite > HDTMA-zeolite > natural soil corresponding to the increase in organic carbon content ($f_{oc}$). The sorption of the pesticides was also affected by pH. The sorption of 2,4-D decreased with the increase in pH, whereas that of atrazine was not changed. This indicated that the sorption capacity ($Q^0$) of 2,4-D and atrazine was not affected by the solution pH because they exist as anionic (deprotonated) forms at pH above pKa. The results indicate that organoclay has a promising potential to reduce chlorinated pesticides in the effluent from golf courses.

비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교 (Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application)

  • 김병혁;정한;김영호
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

A novel barium oxide-based Iraqi sand glass to attenuate the low gamma-ray energies: Fabrication, mechanical, and radiation protection capacity evaluation

  • Al-Saeedi, F.H.F.;Sayyed, M.I.;Kapustin, F.L.;Al-Ghamdi, Hanan;Kolobkova, E.V.;Tashlykov, O.L.;Almuqrin, Aljawhara H.;Mahmoud, K.A.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3051-3058
    • /
    • 2022
  • In the present work, untreated Iraqi sand with grain sizes varied between 100 and 200 ㎛ was used to produce a colored glass sample that has shielding features against the low gamma-ray energy. Therefore, a weight of 70-60 wt % sand was mixed with 9-14 wt% B2O3, 8-10 wt% Na2O, 4-6 wt% of CaO, 3-6 wt% Al2O3, in addition to 0.3% of Co2O3. After melting and annealing the glass sample, the X-ray diffraction spectrometry was applied to affirm the amorphous phase of the fabricated glass samples. Moreover, the X-ray dispersive energy spectrometry was used to measure the chemical composition, and the MH-300A densimeter was applied to measure the fabricated sample's density. The Makishima-Makinzie model was applied to predict the mechanical properties of the fabricated glass. Besides, the Monte Carlo simulation was used to estimate the fabricated glass sample's radiation shielding capacity in the low-energy region between 22.1 and 160.6 keV. Therefore, the simulated linear attenuation coefficient changed between 10.725 and 0.484 cm-1, raising the gamma-ray energy between 22.1 and 160.6 keV. Also, other shielding parameters such as a half-value layer, pure lead equivalent thickness, and buildup factors were calculated.

ISO 9613-2를 이용한 철도 환경소음 예측 모델 개선에 관한 연구 (Study on the improvement of prediction model for the railway environmental noise using ISO 9613-2)

  • 장승호;고효인;홍지영
    • 환경영향평가
    • /
    • 제26권1호
    • /
    • pp.11-26
    • /
    • 2017
  • 철도 소음의 환경영향평가 업무에 있어서 소음도에 대한 정확한 예측이 중요하지만, 국내에서는 overall 소음도의 거리별 측정을 통한 경험식이 근사적으로 이용되고 있다. 본 논문에서는 소음원과 소음전파의 주파수 특성을 고려하여 철도 소음의 예측 정확도를 향상할 수 있는 예측 모델을 제안하였다. 먼저 철도 소음원을 궤도(레일 및 침목), 차륜, 동력, 공력 성분으로 구분하여 각각의 옥타브 밴드 주파수별 음향파워와 속도계수를 정의하고 음향 조도와 궤도/교량 특성을 반영할 수 있는 보정항을 도입하였다. 소음원에서 수음점까지의 전파 특성은 ISO 9613-2를 적용하여 기하학적 확산, 대기 흡음, 지면 효과, 장애물의 회절에 따른 감쇠 및 지향특성을 반영하여 계산하였다. 소음원 음향파워와 지향인자를 추정하기 위하여 전동 소음원 해석 모델 및 수치해석 결과와 통과 소음도 측정값을 이용하였다. 본 철도 소음 예측 모델을 이용하여 여러 철도 차량과 궤도 유형에 따라서 예측한 소음도를 측정값과 비교하여 정확도를 검증하였으며 기존 예측 모델보다 비교적 정확한 예측이 가능하였다. 따라서 본 결과는 철도 환경 소음의 정확한 영향 예측과 효율적인 소음 저감 대책 수립에 활용될 수 있을 것이다.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

인프라사운드 관측을 통한 2004년 울진해역지진의 지반운동 특성 분석 (Analysis of Ground-Motion Characteristics of the 2004 Offshore Uljin Earthquake through Atmospheric Infrasound Observation)

  • 제일영;윤여웅;임인섭
    • 한국지구과학회지
    • /
    • 제41권6호
    • /
    • pp.647-657
    • /
    • 2020
  • 2004년 5월 29일 발생한 울진해역지진(Mw 5.1)과 관련된 대기 인프라사운드 신호가 철원(진앙 거리 321 km) 및 대전(256 km) 관측소에 기록되었다. 신호의 지속시간은 수 분 이상이며, 음원 방향을 지시하는 후방-방위각은 28°이상의 큰 변화를 보였다. 역-투사 방법과 신호 감쇄 보정 결과, 인프라사운드 신호는 삼척-울진-포항까지 연결되는 약 4,600 ㎢ 면적의 지반운동으로 발생하였으며, 음원 최대 크기(BSP)는 11.1 Pa로 계산되었다. 이 결과는 최대지반가속도(PGA) 자료로 계산한 음원 최대 크기(PSP)와도 부합하고 있으며, 지진 발생 당시 인프라사운드 신호 탐지를 가능케 했던 최소 지반운동은 ~3.0 cm s-2 이상으로 확인되었다. 울진해역지진이 비록 동해 해역에서 발생하였지만, 진앙과 가까운 강원도 남부-경상북도의 고지대를 따라 전파한 표면파의 지반운동으로 회절 인프라사운드가 효과적으로 발생한 것으로 해석된다. 인프라사운드 관측을 통한 원거리 지진 지반운동 특성 추정 방법은 지진관측망이 설치되어 있지 않거나 관측소 수가 적은 지역을 대상으로 활용이 가능할 것이다.