• Title/Summary/Keyword: Differential Ratio

Search Result 1,140, Processing Time 0.029 seconds

Transmission Performance Comparison of Direction Detection-Based 100-Gb/s Modulation Formats for Metro Area Optical Networks

  • Chung, Hwan Seok;Chang, Sun Hyok;Lee, Jonghyun;Kim, Kwangjoon
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.800-806
    • /
    • 2012
  • Transmission performances of direct detection-based 100-Gb/s modulation formats are investigated and compared for metro area optical networks. The effects of optical signal-to-noise ratio sensitivity, chromatic dispersion, cross-channel nonlinearity, and transmission distance on the performance of differential 8-ary phase-shift keying (D8PSK), differential phase-shift keying plus three-level amplitude-shift keying (DPSK+3ASK), and dual-carrier differential quaternary phase-shift keying (DC-DQPSK) are evaluated. The performance of coherent dual-polarization quadrature phase-shift keying (DP-QPSK) with block phase estimation and coherent DP-QPSK with digital differential detection are also presented for reference. According to our analysis, all three direct detection modulation formats could transmit a 100-Gb/s signal over several hundred kilometers of a single-mode fiber link. The results also show that DC-DQPSK outperforms D8PSK and DPSK+3ASK, and the performance of DC-DQPSK is comparable to that of coherent DP-QPSK with digital differential detection. The maximum transmission distance of DC-DQPSK is over 1,000 km, which is enough distance for metro applications.

Interference and Efficiency analysis of 2K-H I Type Differential Gear Unit

  • Kim, Yeon-Su;Park, Sang-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.5-14
    • /
    • 2000
  • In the design of epicyclic gearing, the analysis of interference and mechanical efficiency is an important index. As an applied way, epicyclic gearing can be used for planetary gear drive and differential gear unit. In case that one of its components is fixed with intend, it is called planetary gear drive. On the contrary, in case that no component is fixed, it is called differential gear unit. In this paper, various design constraints and interferences are defined for 2K-H I type epicyclic gearing which is a basic arrangement of diverse epicyclic gearings. And various interferences are analyzed, and mechanical efficiency is calculated in case that 2K-H I epicyclic gearing is used for a differential gear unit as the change of gear ratio, cutter pressure angle, addendum modification coefficient. As that results, trend of mechanical efficiency is investigated in the ranges of addendum modification coefficients which would not lead to interferences, and the optimal range of addendum modification coefficient which can generate the maximum mechanical efficiency are presented. In order to prove results of theoretical efficiency analysis, experimental studies are performed.

  • PDF

A Study on the 2nd Harmonic Blocking Scheme and Setting Value of a Current Differential Relay for 154 kV Transformers to Prevent Maloperation (154 kV 변압기 보호용 비율차동계전기 오동작 방지를 위한 2고조파 억제 방식의 적용방법 및 정정값에 관한 연구)

  • Son, Yong-Beom;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.29-37
    • /
    • 2018
  • Inrush current and fault current in a transformer need to be distinguished from one another. In order to do this, KEPCO uses a 2nd harmonic restraint/block method. We use two setting values for 2nd harmonic restraint; 15% and 10%. We also apply per-phase blocking method among various harmonic restraint methods. If the transformer is located at the radial system, we adjust 10% in the 2nd harmonic restraint, but this method is not enough to prevent mal-operations of the current differential relay and let us spend more time to change setting value again as the power system changes. In this paper, a more reasonable setting value for a 2nd harmonic blocking scheme in KEPCO is proposed. To present a proposed method, the fault data of the current differential relays which have occurred since 2009 are analyzed. To evaluate the performance of the proposed method, the results of the RTDS test for the current differential relay of the transformer by KEPCO are analyzed.

A scalar MSDD with multiple antenna reception of Differential Space-Time π/2-Shifted BPSK Modulation

  • Kim Jae-Hyung;Hwang Seung-Wook;Kim Jung-Keun;Kim Yong-Jae
    • Journal of Navigation and Port Research
    • /
    • v.30 no.2
    • /
    • pp.167-172
    • /
    • 2006
  • In this paper, the issue of blind detection of Alamouti-type differential space-time (ST) ${\pi}/2$-shifted BPSK modulation in static Rayleigh fading channels is considered. We introduce a novel transformation to the received signal from each receiver antenna such that this binary ST modulation, which has a second-order transmit-diversity, is equivalent to QPSK modulation with second-order receive-diversity. The pre-detection combining of the result of transformation allows us to apply a low complexity detection technique specifically designed for receive-diversity, namely, scalar multiple-symbol differential detection (MSDD). With receiver complexity proportional to the observation window length, our receiver can achieve the performance 1.5dB better than that of conventional differential detection ST and 0.5dB worse than that qf a coherent maximum ratio combining receiver (with differential decoding) approximately.

Measurement and Verification of Thermal Conductivity of Multilayer Thin Dielectric Film via Differential 3$\omega$ Method (차등 3$\omega$ 기법을 이용한 다층 유전체 박막의 열전도도 측정 및 검증)

  • Shin Sang-Woo;Cho Han-Na;Cho Hyung-Hee
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.254-259
    • /
    • 2005
  • In this study, measurement of thermal conductivity of multilayer thin dielectric film has been conducted via differential 3$\omega$ method. Also, verification of differential 3$\omega$ method has been accomplished with various proposed criteria. The target film for measurement is 300 nm silicon dioxide and this thin film is covered with various thicknesses of upper protective layer. The upper protective layer is inserted between the target film and the heater line for purpose of electrical insulator or anti-oxidation barrier since the target film may be a good electrical conductor or a well-oxidizing material. However, the verification of differential 3$\omega$ method has not been conducted. Thus we have shown that the measurement of thermal conductivity of thin films with upper protective layer via differential 3$\omega$ method is verified to be reliable as long as the proposed preconditions are satisfied. Experimental results show that the experimental errors tend to increase with aspect ratio between upper protective layer thickness and width of the heater line due to heat spreading effect.

  • PDF

Performance Improvement of Protective Relaying for Large Transformer by Using Voltage-Current Trend and Flux-Differential Current Slope Characteristic (전압-전류 추이와 자속-차전류 기울기 특성을 이용한 변압기 보호계전기법의 성능 개선)

  • Park, Chul-Won;Park, Jae-Sae;Jung, Yun-Man;Ha, Kyung-Jae;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.43-50
    • /
    • 2004
  • Percentage differential characteristic relaying(PDR) has been recognized as the principal basis for power transformer protection. Second harmonic restraint PDR has been widely used for magnetizing inrush in practice. Nowadays, relaying signals can contain 2nd harmonic component to a large extent even in a normal state, and 2nd harmonic ratio indicates a tendency of relative reduction because of the advancement of material. Further, as the power system voltage becomes higher and more underground cables are used, larger 2nd harmonic component in the differential current under internal fault is observed. And then, conventional 2nd harmonic restraint PDR exposes some doubt in reliability. It is, therefore, necessary to develop a new algorithm for performance improvement of conventional protective relaying. This paper proposes an advanced protective relaying algorithm by using voltage-current trend and flux-differential current slope characteristic. To evaluate the performance of the proposed algorithm, we have made comparative studies of PDR, fuzzy relaying and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP, and data collection is made through simulation of various internal faults and inrush. As the results of test, the new proposed algorithm was proven to be faster and more reliable.

MOS Transistor Differential Amplifier (MOS Transistor를 이용한 착동증폭기)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.4
    • /
    • pp.2-12
    • /
    • 1967
  • A pair of insulated-gate metal-oxide-semiconductor field-effect transistor has been used to measure the direct current produced from the ionization chamber in the range of to A. An analisis of direct-current differential amplifier giving the expressions of the common-mode rejection ratio and the rralization of the constant-current generator to give very large effective source resistance has been presented. Voltage gain is 6.6, drift at the room temperature is 1.5mv per day. The common-mode rejection ratio is obtained maximum 84db. These facts give the feasibility of small direct-current measurements by utilizing this type transistors.

  • PDF

Nonlinear vibration of hybrid composite plates on elastic foundations

  • Chen, Wei-Ren;Chen, Chun-Sheng;Yu, Szu-Ying
    • Structural Engineering and Mechanics
    • /
    • v.37 no.4
    • /
    • pp.367-383
    • /
    • 2011
  • In this paper, nonlinear partial differential equations of motion for a hybrid composite plate subjected to initial stresses on elastic foundations are established to investigate its nonlinear vibration behavior. Pasternak foundation and Winkler foundations are used to represent the plate-foundation interaction. The initial stress is taken to be a combination of pure bending stress plus an extensional stress in the example problems. The governing equations of motion are reduced to the time-dependent ordinary differential equations by the Galerkin's method. Then, the Runge-Kutta method is used to evaluate the nonlinear vibration frequency and frequency ratio of hybrid composite plates. The nonlinear vibration behavior is affected by foundation stiffness, initial stress, vibration amplitude and the thickness ratio of layer. The effects of various parameters on the nonlinear vibration of hybrid laminated plate are investigated and discussed.

Free Vibrations of Horizontally Circular Curved Beams with Warping and Rotatory Inertia (워핑과 회전관성을 고려한 원호형 수명 곡선보의 자유진동)

  • 이병구;박광규;오상진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.308-314
    • /
    • 2000
  • This study explores the free, out-of-plane vibrations of horizontally circular curved beams. The differential equations governing the free vibration of such beams, including the effects of warping and rotatory inertia, are derived and solved numerically. The Runge-Kutta method and the Determinant Search method combined with Regula-Falsi method are used to integrate the differential equations and to obtain the natural frequencies, respectively. The lowest three natural frequencies are calculated over a wide range of non-dimensional system parameters: the horizontal rise to span length ratio, the slenderness ratio, the stiffness parameter, and the warping parameter. It is expected that the results obtained herein can be used practically for the design of curved member systems.

  • PDF

Buckling Loads of Tapered Columns due to Dynamic Concept (동적개념에 의한 변단면 기둥의 좌굴하중)

  • 이병구;우정안
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.4
    • /
    • pp.97-105
    • /
    • 1992
  • The main purpose of this paper is to present the buckling loads of tapered columns due to dynamic concept. The ordinary differential equation governing the bucking loads for tapered columns is derived on the basis of dynamic concept. Three kinds of cross sectional shape are considered in the governing equation. The Improved Euler method and Determinant Search method are used to perform the integration of the differential equation and to determine the buckling loads, respectively. The hinged-hinged, hinged-clamped, clamped-clamped and free-clamped end constraints are applied in numerical examples. The buckling loads are reported as the function of section ratio, and the effects of cross-sectional shapes are investigated. The buckling load equation, which are fitted by numerical data, are proposed as a function of section ratio. It is expected that these equations can be utilized in structural engineering field.

  • PDF