• Title/Summary/Keyword: Difference Values

Search Result 6,903, Processing Time 0.034 seconds

A Study on Reliability of Computerized Cephalometric Analysis System (두부 방사선 규격사진 컴퓨터 분석기의 신뢰도에 관한 연구)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.47-55
    • /
    • 1994
  • To investigate the reliability and reproducibility of the computerized cephalometric analysis system, se compared the differences of the 10 linear and 13 angular measurements by manual works and the use of computerized cephalometric analysis system. We obtained as follows : 1. There was not significant difference between maean values of 22 manual and computerized measurements. 2. There was not significant difference between mean differences of manual and computerized cephalometric analysis data taken by same examiner except facial depth, facial length and posterior facial height. 3. There was not significant difference between mean differences of two trials of the computerized cephalometric analysis data by same examiner in all measurements. 4. There was not significant difference between mean differences of the computerized cephalometric analysis data by two examiners except FMIA and IMPA. According to this result, we guess the use of computerized cephalometric analysis system is useful on diagnosis and treatment planning of othodontic patients.

  • PDF

An Algorithm for Detecting CT Saturation (변류기 2차전류의 포화 여부 판단 알고리즘)

  • Gang, Yong-Cheol;Ok, Seung-Hun;Gang, Sang-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.275-278
    • /
    • 2001
  • This paper presents an algorithm for detecting current transformer (CT) saturation. At the instants of beginning (or end) of saturation, as a magnetizing inductance of the core is changed significantly, the shapes of the secondary current are also changed significantly though secondary currents are continuous the instants. At the instants, the second-order of third-order difference of the secondary current has big values. Thus, the third difference of the current is used to detect the beginning/end of CT saturation in this paper. If the magnitude of third-order difference of the secondary current is larger than a threshold value, the CT begins of ends saturation at the instants. The proposed detection method is unaffected by the amount of residual flux. The results of various tests with residual flux from -80% to +80% indicate satisfactory performance of the method.

  • PDF

CERTAIN DIFFERENCE POLYNOMIALS AND SHARED VALUES

  • Li, Xiao-Min;Yu, Hui
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.5
    • /
    • pp.1529-1561
    • /
    • 2018
  • Let f and g be nonconstant meromorphic (entire, respectively) functions in the complex plane such that f and g are of finite order, let a and b be nonzero complex numbers and let n be a positive integer satisfying $n{\geq}21$ ($n{\geq}12$, respectively). We show that if the difference polynomials $f^n(z)+af(z+{\eta})$ and $g^n(z)+ag(z+{\eta})$ share b CM, and if f and g share 0 and ${\infty}$ CM, where ${\eta}{\neq}0$ is a complex number, then f and g are either equal or at least closely related. The results in this paper are difference analogues of the corresponding results from.

Multi-scale Local Difference Directional Number Pattern for Group-housed Pigs Recognition

  • Huang, Weijia;Zhu, Weixing;Zhang, Zhengyan;Guo, Yizheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.9
    • /
    • pp.3186-3203
    • /
    • 2021
  • In this paper, a multi-scale local difference directional number (MLDDN) pattern is proposed for pig identification. Firstly, the color images of individual pig are converted into grey images by the most significant bits (MSB) quantization, which makes the grey values have better discrimination. Then, Gabor amplitude and phase responses on different scales are obtained by convoluting the grey images with Gabor masks. Next, by calculating the main difference of local edge directions instead of traditionally edge information, the directional numbers of Gabor amplitude and phase responses are encoded. Finally, the block histograms of the encoded images are concatenated on each scale, and the maximum pooling is adopted on different scales to avoid the high feature dimension. Experimental results on two pigsties show that MLDDN impressively outperforms the other widely used local descriptors.

A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM (수종 임플랜트 시스템에서의 회전력에 관한 연구)

  • Moon, Ick-Hun;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

The Effect of Lumbar Stabilization Exercise For Caregivers With Chronic Low Back Pain (요부안정화 운동프로그램이 요양보호사의 만성요통에 미치는 영향)

  • Lee, Jae-Moon;Yi, Chung-Hwi;Kwon, Oh-Yun;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.18 no.2
    • /
    • pp.9-17
    • /
    • 2011
  • The objective of this research was to examine the effects of lumber stabilization exercise and a general physiotherapy program for caregivers with chronic low back pain. Sixteen people participated in this study and were randomly assigned to two groups for either lumbar stabilization exercise or for general physiotherapy, respectively. The experiment was performed for eight weeks. To examine the general as well as the medical characteristics of the participants, the following measurements were used: Visual Analogue Scale (VAS); Oswestry Disability Index (ODI); Back Performance Scale (BPS); Roland - Morris Disability Questionnaire (RMDQ); and Beck Depression Index (BDI). To compare the general and medical characteristics of the participants in the two groups, an independent t test were used. During the experiment, a paired t test was conducted to determine whether there was a significant difference in the values of VAS, ODI, BPS, RMDQ, and BDI before and after the experiment. To examine the difference in the VAS, ODI, BPS, RMDQ, and BDI values in the two groups, ANCOVA was used with pre test values as a covariate. According to the test results, in the lumbar stabilization exercise group, the VAS, ODI, BPS, RMDQ, and BDI values showed a statistically significant difference before and after the test (p<.05). In comparison, in the general physiotherapy program group, only the ODI and BPS values showed a statistically significant level of improvement. Regarding the degree of improvement, participants in the lumbar stabilization exercise group showed statistically significant progress compared to those in the general physiotherapy group. In summary, lumbar stabilization exercise is regarded as more effective than general physiotherapy for treating caregivers with chronic low back pain. In future studies, it will be useful to expand the research and to examine the long term effects of lumbar stabilization exercise on workers.

A Study on the Loss of Tooth Substance and Surface Changes following Root Planing (치근면 활택술후 치질삭제와 표면형태변화에 관한 연구)

  • Heo, Soo-Rye;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyoug-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.351-372
    • /
    • 1998
  • The purpose of this study was to evaluate in vitro effects of the loss of tooth substance and root surface changes following root planing with various periodontal instruments. The 39 extracted human teeth due to severe periodontal disease were included. The total 50 root surfaces of 30 teeth were root planed with following instruments : Group 1, with Gracey curette, Group 2, with ultrasonic scaler, Group 3, with rotating root planing bur, Group 4, with Gracey curette plus rubber cup polishing, and Group 5, with ultrasonic scaler plus rubber cup polishing. Following root planing, the amount of tooth substance loss was evaluated by measuring the weight of the removed tooth substance and then 5 specimens ($5{\times}5{\times}2mm$) were randomly selected from the each group for roughness measurement. Root planed areas of each specimen were subjected to five measurements using the Profilometer and an average surface roughness values(Ra) for each group was obtained. Statistical difference for roughness values of each group was analyzed using oneway ANOVA and student t-test. For scanning electron microscopic(SEM) examination of root surface changes following root planing, 15 root surfaces of remaining 9 teeth were root planed and 3 specimens were randomly selected. The mean loss of tooth substance removed was Group 1, $7.0{\pm}1.09mg$, Group 2, $1.3{\pm}1.00mg$, Group 3, $5.8{\pm}1.72mg$, Group 4, $8.7{\pm}1.34mg$, and Group 5, $4.5{\pm}1.68mg$ following root palning, respectively. These results indicate that curette is effective instrument in the respect of diseased root substance removal. The average surface roughness values are following results : Group 1 and Group 4 were the smoothest surface ($Ra=0.34{\pm}0.06{\mu}m$, $Ra=0.34{\pm}0.04{\mu}m$, respectively) and Group 2 was the roughest surface ($Ra=2.09{\pm}0.06{\mu}m$). Statistical analysis of roughness values demonstrated a highly significant difference (P<0.05) between each experimental groups. However, no statistically significant difference in roughness values were observed between the Group 1 and Group 4. The results in this study suggest that curette and/or polishing procedure should be done after root planing with ultrasonic scaler and caution should be used with dia-mond-coated bur during routine root planing procedure.

  • PDF

Anti-inflammatory Effect of Artemisia Capillaris Thunberg in Lipopolysaccharide-exposed Rats (인진호(茵蔯蒿)가 LPS 염증유발 흰쥐의 전염증성 cytokine 생산 및 혈액성상에 미치는 영향)

  • Seo, Yong-Seok;Lee, Eun;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2010
  • Objectives : The present study investigated anti-inflammatory effect of Artemisia Capilaris Thunberg in lipopolysaccharide-exposed rats. Methods : We divided lipopolysaccharide-exposed Sprague-Dawley rats into 4 groups. They were normal group, feed with 100 mg/kg Artemisia Capillaris Thunberg group, feed with 200 mg/kg Artemisia Capillaris Thunberg group and feed with 300 mg/kg Artemisia capilaris Thunberg group. They were administered for 6 weeks. We measured counts of red blood cell(RBC), the values of hemoglobin(Hb) and packed cell volume(PCV), plasma total protein concentration, albumin concentration, the ratio of albumin/globulin, the activities of plasma glutamic oxaloacetic transaminase(GOT), glutamic pyruvic transaminase(GPT), lactate dehydrogenase(LDH), the counts of white blood cell(WBC), the ratio of neutrophils, lymphocytes, monocytes, basophils, eosinophils, the concentration of plasma interleukin-$1{\beta}$($IL-1{\beta}$), plasma interleukin-6(IL-6), plasma tumor necrosis factor-$\alpha$($TNF-{\alpha}$), plasma interleukin-10(IL-10), the concentration of liver $IL-1{\beta}$ and IL-6, $TNF-{\alpha}$, IL-10. Results : Counts of RBC and the values of Hb and PCV, plasma total protein concentration and albumin concentration, the activities of plasma GOT, GPT and LDH showed no significant difference in the treatment groups. and the ratio of albumin/globulin was increased in Artemisia Capillaris Thunberg groups. The counts of WBC showed lower values in Artemisia Capillaris Thunberg groups than those of control group, In the ratio of neutrophils Thunberg groups. The ration of monocytes, basophils and eosinophils were below 5%, and showed no characteristic trend. The concentration of plasma interleukin-$1{\beta}$($IL-1{\beta}$), plasma inerleukin-6(IL-6) and plasma tumor necrosis factor-$\alpha$($TNF-{\alpha}$) showed a lower values in the Artemisia Capillaris Thunberg groups than those of control group, and the concentration of plasma interleukin-10(IL-10) showed no significant difference in the treatment groups. The concentration of liver $IL-1{\beta}$ and IL-6 showed a lower values in the Artemisia Capillaris Thunberg groups than those of control group, however the concentration of liver $TNF-{\alpha}$ and IL-10 showed no significant difference in the treatment groups. Conclusions : The Artemisia Capillaris Thunberg groups gives positive results of anti-inflammatory response by lipopolysaccharide(LPS) derivation.

A Comparative Study on HSI and MaxEnt Habitat Prediction Models: About Prionailurus bengalensis (HSI와 MaxEnt를 통한 삵의 서식지 예측 모델 비교 연구)

  • Yoo, Da-Young;Lim, Tai-Yang;Kim, Whee-Moon;Song, Won-Kyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.5
    • /
    • pp.1-14
    • /
    • 2021
  • Excessive development and urbanization have destroyed animal, plant, habitats and reduced biodiversity. In order to preserve species diversity, habitat prediction studies are have been conducted at home and overseas using various modeling techniques. This study was conducted to suggest optimal habitat modeling research by comparing HSI and MaxEnt, which are widely used among habitat modeling techniques. The study was targeted on the endangered species of Prionailurus bengalensis in nearby areas (5460.35km2) including Cheonan City, and the same data were used for analysis to compare those models. According to the HSI analysis, Prionailurus bengalensis's habitat probability was 74.65% for less than 0.5 and 25.34% for more than 0.5 and the top 30% were forest (99.07%). MaxEnt's analysis showed that 56.22% of those below 0.5 and 43.79% of those above 0.5 were found to have a high explanatory power of 78.3% of AUC. The Paired Wilcoxn test, which evaluated the significance of thoes models, confirmed that the mean difference between the two models was statistically significant (p<0.05). Analysis of the differences in the results of those models using the matrix table shows that score 24.43% HSI and MaxEnt was accordance,12.44% of the 0.0 to 0.2 section, 7.22% of the 0.2 to 0.4 section, 2.73% of the 0.4 to 0.6 section, 1.96% of the 0.6 to 0.8, and 0.08% of the 0.9 to 1.0. To verify where the score difference appears, the result values of those models were reset to values from 1 to 5 and overlaid. Overlapping analysis resulted in 30.26% of the Strongly agree values, 56.77% of the agree values, and 11.92% of the Disagree values. The places where the difference in scores occurs were analyzed in the order of forest (45.23%), agricultural land (34.57%), and urbanization area (7.65%). This confirmed that the analysis of the same target species within the same target site also has differences in forecasts depending on the modelling method. Therefore, a novel analysis method combining the advantages of each modeling in habitat prediction studies should be developed, and future study may be used to select Prionailurus bengalensis and species-protected areas and species protection areas in the future. Further research is judged to require higher accuracy studies through the use of various modeling techniques and on-site verification.

CEPHALOMETRIC ANALYSIS FOR CHILDREN WITH NORMAL OCCLUSION IN THE PRIMARY DENTITION (정상교합을 가진 유치열기 아동의 두부방사선 계측학적 연구)

  • Suh, Moon-Sun;Son, Heung-Kyu;Baik, Hyung-Sun;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.109-118
    • /
    • 2005
  • In the field of pediatric dentistry, comparison and analysis of cephalogram values of children are important fir evaluation of growth and development, and are essential to evaluate the craniofacial form and growth pattern for early diagnosis of malocclusion. For this, cephalographic norm values are important, but not many studies on the primary dentition exist. To compare the past norm values of normal occlusion in the primary dentition with current norms, preschool children, 4 to 5 years of age, with normal occlusion in the primary dentition who visited our hospital were examined. Among these children, 46 children with normal facial form and developmental status were chosen for evaluation of cephalogram values. The following results were as follows: 1. For skeletal values, the angular values showed no significant differences between males and females, and the linear values were generally greater in males than females. 2. SNA was $81.3^{\circ}$, SNB was $76.6^{\circ}$ and ANB difference was $4.7^{\circ}$. 3. The ratio for Mandibular body length to Anterior cranial base length was 0.9 : 1 for both male and female and the ratio for posterior facial height to anterior facial height was 61.4 % for male, 62.0 % for female. 4. For dental values, IMPA was $84.2^{\circ}$ and UA to SN was $90.8^{\circ}$. 5. The upper lip to Ricketts esthetic line was positioned 2.6 mm anteriorly, and the lower lip to Ricketts esthetic line was positioned 2.5 mm anteriorly.

  • PDF