• 제목/요약/키워드: Dielectric diagnosis

검색결과 49건 처리시간 0.022초

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

고분자 애자 오손정도의 전자파 신호 분석 (Signal Classification of Electromagnetic Wave for Contaminated Degree on Polymer Insulator)

  • 박재준;최인혁;정명연;이승욱;서의원;가평현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.662-665
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high-voltage electrical apparatus However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time-frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this paper analyzes the electromagnetic waves emitted from PD using Wavelet transform. This paper experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. This method is shown to be useful for detecting prediction of contamination degree.

  • PDF

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (Fatten Analysis of Trouble Signal on DS for GIS using Neural Network)

  • 김종서;이은석;천종철
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.

카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석 (Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination)

  • 박재준
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.113-118
    • /
    • 2004
  • 기존의 누설전류기법에서 한층 진일보된 비접촉식 수신용 안테나를 이용하여 복잡한 지역과 광범위한 지역에서 효율적인 고분자 애자의 오손정도를 진단하기 위하여 본 연구를 착수하였다. 착수된 연구는 가공된 챔버 내 설치된 고분자애자에 인위적으로 카올린과 소금을 혼합후 증류수에 혼합하여 인공 오손실시 후 방사전자파와 스페트럼 그리고 부분방전전하량을 동시에 측정 후 전자파 신호에 대한 카올린의 오손정도에 대한 특징추출을 위하여 다우비치 이산웨이블렛 변환기법에 적용 후 각각의 통계적인 파라미터의 특징을 추출하였다.

  • PDF

에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구 (A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator)

  • 최철광;이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구 (Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation)

  • 이상우
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 본 논문은 전력 케이블의 절연체인 XLPE 시료에 상용주파수 교류전압을 인가하였을 때, 절연열화에 의한 보이드방전 펄스신호와 AE신호 및 트리진전 특성을 검출하고 관찰하였다. 또한 XLPE 절연체의 트리 채널내 인가전압에 따라 보이드방전 펄스신호와 AE신호를 각각 관측하였다. 실험 결과 전력 케이블의 절연체인 XLPE 시료의 보이드 존재 유 무에 따른 트리진전 형상은 보이드 존재시에는 수지형으로 성장하였으나, 무보이드시에는 수초형으로 성장하였다. XLPE 절연체내의 트리진전 특성은 보이드 존재시에는 열화시간이 경과함에 따라 급격히 증가하였으나, 무보이드시에는 열화 시간이 경과함에 따라 트리의 성장 형상은 감소되는 것으로 나타났다. 전력 케이블 절연체인 XLPE의 트리 채널내 보이드방전에 의한 AE신호의 주파수 스펙트럼으로 분석한 결과, AE신호의 크기에 따라 변화되었으며 그 주파수 영역은 대략 1.0[MHz] 이하의 분포인 것으로 관측되었다.

개스분석에 의한 주상변압기의 예방진단에 관한 연구 -자외-가시선 흡수분광광도법에 의한 절연유의 열화도 측정- (A Study on Preventive Diagnosis of the Pole Transformer by Gas Analysis -Measurement of Aging of Insulating Oil by UV-Visible Spectrophotometric Method-)

  • 곽희로;남영우;윤영자;남궁미옥;이동준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권5호
    • /
    • pp.94-100
    • /
    • 1996
  • 자외- 가시선 흡수분광광도법을 적용하여 주상변압기 절연유의 판정기준을 제시하였다. 절연유가 열화하면 절연유의 전기적 특성치가 저하할 뿐만 아니라 흡광도값도 변하게 된다. tan$\delta$와 절연파괴전압과 같은 전기적 특성치를 흡광도값과 비교하여 흡광도값에 의한 절연유의 판정기분을 설정하였다. 흡광도값이 0.580 이하는 양호, 요주의는 0.580~0.900, 불량은 0.900이상이다. 자외-가시건 흡수분광광도법은 절연유의 열화분석에 적용할 수 있으며, 기존의 육안에 의한 절연유 검사 방법을 대체할 수 있을 것으로 기대된다. 그러나 분광광도법을 현장에 적용하려면 저렴하고 경량화된 휴대용 분광광도계의 개발이 필요하다.

  • PDF

VLF를 활용한 전력케이블 진단 시뮬레이터 구현 (Implementation of Power Cable Diagnostic Simulator using VLF)

  • 김국;어익수
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.593-602
    • /
    • 2020
  • 국내 공장이나 지중에 설치되어 있는 전력 케이블은 제조과정, 설치, 사용 중의 환경여건에 따라 사고가 발생할 수 있는 필연성을 갖고 있다. 전력 케이블에서 사고가 일어났을 때 막대한 경제적 손실과 사회적 혼란을 야기할 수 있어 이를 미연에 방지하고자 진단을 통한 케이블의 예방관리의 중요성이 증대되고 있다. 이에 본 논문에서는 현장에서 발생 될 수 있는 케이블의 설치나 제조결함, 경년열화로 문제가 될 수 있는 부분을 모의하여 진단시료 케이블을 제작하였고, 최근 도입되어 적용되고 있는 VLF(Very Low Frequency)장비를 사용하여 유전정접(tan 𝛿 ; TD), 부분방전(Partial Discharge ; PD)시험을 실시하였고, 0.1Hz 주파수를 갖는 VLF전원을 가압을 한 후 HFCT(High Frequency Current Transformer)를 이용한 부분방전과 AC(상용주파)내압 장비를 이용하여 가압한 후 PD측정을 수행하였다. 그 결과, VLF를 통한 2.0U0 전압에서 B, C상 결함시료에서는 내부 부분방전을 측정할 수 있었으며 A상 정상시료에서는 0.5~2.0U0 전압에서 모두 노이즈로 측정되었다. 또한, 상용주파수의 AC(60Hz) 내압장비를 통한 1.5U0전압에서 측정하여 그 실효성을 검증하였다. 활선상태에서의 부분방전은 1.0U0의 사용전압에서 측정 되어지며, 장비를 설치할 때 위험성이 있고, AC내압장비는 부피나 무게 등에 의해 이동의 어려움이 있어 사선상태의 VLF를 통한 진단방법이 안전과 실효성이 있음을 알 수 있었다.