• Title/Summary/Keyword: Dielectric Plate

Search Result 183, Processing Time 0.025 seconds

Study on the Breakdown of the Transformer Insulating Oil in Nonuniform Electric Field (불평등 전계에서 변압기 절연유 절연파괴 연구)

  • Ha-Young Cho;Soon-Hyung Lee;Mi-Yong Hwang;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.280-285
    • /
    • 2023
  • A breakdown voltage and breakdown electric field of the transformer insulating oil of liquid dielectric were studied in uniform electric field and non-uniform electric field and the transformer insulating oil was observed by the process reached breakdown. Insulation performance evaluation of the liquid dielectric was evaluated at the electrode spacing of 2.5 mm under the conditions of domestic and international standards (KS C IEC 60156), so a comparative review was conducted at the electrode spacing of 2.5 mm. When the electrode spacing is 2.5 mm, the average breakdown voltage is 38.5 kV for sphere-sphere electrodes, 26.6 kV for plate-plate electrodes, 22.9 kV for needle-needle electrodes, and 24.3 kV for sphere-needle electrodes. 23.7 kV for the sphere-plate electrode, and 20.7 kV for the needle-plate electrode. From these results, it can be seen that the average value of the breakdown voltage at the electrode spacing of 2.5 mm, in ascending order, is sphere-sphere, plate-plate, sphere-needle, sphere-plate, needle-needle and needle-plate. It was found that the breakdown voltage of the unequal field was lower than that of the equal field.

Removal of Gaseous Toluene using a Plate-type Dielectric Barrier Discharge Reactor (평판형 전극으로 구성된 유전체 배리어 방전 반응기를 이용한 톨루엔 저감 특성)

  • Park, Jae-Hong;Jo, Yoon-Shin;Yoon, Ki-Young;Byeon, Jeong-Hoon;Hwang, Jung-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.6
    • /
    • pp.641-648
    • /
    • 2008
  • A plate-type dielectric barrier discharge (DBD) reactor was designed and tested for removal of gaseous toluene. The DBD reactor consisted of 9 parallel plate electrodes, four of which were grounded. An AC voltage of rectangular waveform ($5{\sim}8.5kV$, $60{\sim}1,000Hz$), was applied to the other five electrodes. The gaseous toluene passed through the DBD reactor and its concentration was measured by a real-time gas analyzer. The carbon monoxide (CO) and carbon dioxide ($CO_2$) which were produced by decomposition of toluene in the DBD reactor, were sampled and analyzed by a micro gas chromatography. The maximum toluene removal efficiency was 51.4%.

Structural Properties of Dielectric Barrier Reactor with Hole (DBH) for CF4 Decomposition

  • Jung Jung Gun;Kim Jong Suk;Park Jae Yoon;Kim Kwang Soo;Rim Geun Hie
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.4
    • /
    • pp.30-35
    • /
    • 2003
  • In this paper, the $CF_4$ decomposition efficiency is investigated for three simulated plasma reactors that are needle plate reactor, metal particle reactor, and dielectric barrier reactor with hole (DBH). The$CF_4$ decomposition efficiency by DBH is much better than that by needle plate reactor or metal particle reactor. When applied voltage is increased up to the critical voltage for spark formation in the all reactors, the $CF_4$ decomposition efficiency is increased. The $CF_4$ decomposition efficiency in needle plate reactor and metal particle reactor is about $12\%$ and $22\%$ respectively at applied voltage of 23 kV (consumption power: 110 W) and $CF_4$ concentration of 500 ppm, however, the $CF_4$ decomposition efficiency is more than $95\%$ in case of DBH. DBH should be much better than two reactors investigated for $CF_4$ decomposition.

Evaluation and Determination of Air Void for Asphalt Concrete using a dielectric constant measurement (유전율 측정을 통한 아스팔트 콘크리트의 공극률 추정 연구)

  • Kim, Boo-Il;Kim, Yeong-Min;Cho, In-Sun
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.95-104
    • /
    • 2009
  • This study was conducted to evaluate the relationship between the dielectric constant and air void of asphalt concrete. Standard specimens that have air voids of various range $(0%{\sim}20%)$ were used to measure the dielectric constant using parallel plate method that measures low frequency dielectric constant. From the tests, dielectric constant of asphalt concrete was tend to decrease as the frequency was increased, and the decrement slope was varied with the types of asphalt binders. Dielectric constant was decreased linearly as air void was increased from zero to twenty percent. Consequently, the effect of temperature and moisture content on dielectric constants of asphalt concrete was evaluated to develop the standard curve between dielectric constant and air void of asphalt concrete. The standard curve developed in this study can be used to calibrate or develop the algorithm of non-destructive density gauge.

  • PDF

Active vibration control: considering effect of electric field on coefficients of PZT patches

  • Sharma, Sukesha;Vig, Renu;Kumar, Navin
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1091-1105
    • /
    • 2015
  • Piezoelectric coefficient and dielectric constant of PZT-5H vary with electric field. In this work, variations of these coefficients with electric field are included in finite element modelling of a cantilevered plate instrumented with piezoelectric patches. Finite element model is reduced using modal truncation and then converted into state-space. First three modal displacements and velocities are estimated using Kalman observer. Negative first modal velocity feedback is used to control the vibrations of the smart plate. Three cases are considered v.i.z case 1: in which variation of piezoelectric coefficient and dielectric constant with electric field is not considered in finite element model and not considered in Kalman observer, case 2: in which variation of piezoelectric coefficient and dielectric constant with electric field is considered in finite element model and not considered in Kalman observer and case 3: in which variation of piezoelectric coefficient and dielectric constant with electric field is considered in finite element model as well as in Kalman observer. Simulation results show that appreciable amount of change would appear if variation of piezoelectric coefficient and dielectric constant with r.m.s. value of electric field is considered.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Corona Discharge and Ozone Generation Characteristics of a Slit Dielectric Barrier Discharge Type Plasma Reactor with a Third Electrode (3전극이 부설된 틈새 장벽방전형 플라즈마장치의 코로나 방전 및 오존발생 특성)

  • Moon, Jae-Duk;Jung, Jae-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.583-587
    • /
    • 2007
  • Corona discharge and ozone generation characteristics of a slit dielectric barrier discharge type wire-plate plasma reactor with a third electrode have been investigated. When a third electrode is installed on a slit of the slit barrier, where an intense corona discharge occurs, it is found that a significantly increased ozone output could be obtained. This, however, indicates that the third electrode can activate the corona discharges both of the discharge wire and the slit of the slit barrier in the plasma reactor. As a result, a thin stainless wire, used as the third electrode has a strong effect to influence the corona discharge of the slit and corona wire, especially to the negative corona discharge. Higher amounts of the output ozone and ozone yield, about 1.27 and 1.29 times for the negative corona discharge, can be obtained with the third electrode, which reveals the effectiveness of the third electrode.

Precise Measurement of Dielectric Constant Using Cross Capacitance Measurement Method (Cross Capacitance 측정법을 이용한 유전상수 정밀측정)

  • Kim, Han-Jun;Kang, Jeon-Hong;Yu, Kwang-Min;Lee, Sei-Hyun;Koo, Kyung-Wan;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1287-1288
    • /
    • 2007
  • The cross capacitor electrode system applied Thompson-Lampard theorem for precise and accurate measurement of dielectric constants is studied in this study. The capacitance derived from cross capacitor is calculated by the equation of ($C=\frac{{\epsilon}ln2}{\pi}{\cdot}$ effectivelength of electrode) which is very different from the equation of capacitance derived from parallel plate capacitor. From above mentioned reason, the capacitance measurement uncertainty of cross capacitor can be reduced then that of the parallel plate capacitor. the measurement dielectric constant measured by cross capacitor electrode method is one order more accurate and precise than that of 3-electrode method.

  • PDF

The Simulation of Electric Field Distribution of Dielectric Tube with Single Layer and Globular Dielectric in Water (수중에서 구형 유전체와 단층 절연 방전관의 전계 분포 시뮬레이션)

  • Lee, Dong-Hoon;Park, Jae-Youn;Lee, Jae-Dong;Park, Hong-Jae;Koh, Hee-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1119-1122
    • /
    • 2003
  • In this paper, the electric field distribution in dielectric tube with one layer and spherical dielectric in water was simulated. The reactor was made up of the spherical dielectric that is diameter 2.5[mm], ${\epsilon}_r$ : 5, 100, 1000, 5000 respectively and one glass plate being 2[mm] thickness, ${\epsilon}_r$ : 5 as electrode. The discharge gap was 7[mm]. As a result of the simulation, in case of being about the same value between the dielectric constant of spherical dielectric and water, when the reactor was applied to high voltage dielectric polarization characteristic was trending toward disappearance. To get more strong electric field, the dielectric constant should be higher comparatively, Increasing the spherical dielectric constant, the location of equippotential line was shifting from the interior to the exterior.

  • PDF

The Simulation of Electric Field Distribution of Dielectric Tube with Two Layers and Gloular Dielectric in Water (수중에서의 이중 절연 방전관과 구형 유전체의 전계 분포 시뮬레이션)

  • Lee, Dong-Hoon;Park, Jae-Youn;Park, Hong-Jae;Koh, Hee-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1143-1146
    • /
    • 2003
  • This paper was simulated the electric field distribution in dielectric tube with two layers and spherical dielectric in water. The reactor was made up of the spherical dielectric that is diameter : 2.5[mm], ${\epsilon}_r$ : 5, 25, 100, 1000, 5000 respectively and two glass plate being 2[mm] thickness, ${\epsilon}_r$ : 5 as electrode. The discharge gap was 9[mm]. As a result of the simulation, in case of being about the same value between the dielectric constant of spherical dielectric and water, when the reactor was applied to high voltage, dielectric polarization characteristic was trending toward disappearance. To get more strong electric field, the dielectric constant should be higher comparatively, Increasing the spherical dielectric constant, the location of equippotential line was shifting from the interior to the exterior.

  • PDF