• 제목/요약/키워드: Die Coping

검색결과 17건 처리시간 0.025초

SLM 방식으로 제작한 도재관 금속하부구조물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal fit of metal copings fabricated by selective laser melting)

  • 배성령;이하빈;노미준;김지환
    • 대한치과기공학회지
    • /
    • 제45권1호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: To evaluate the marginal and internal fit of metal coping fabricated by a metal three-dimensional (3D) printer that uses selective laser melting (SLM). Methods: An extraoral scanner was used to scan a die of the prepared maxillary right first molar, and the coping was designed using computer-aided design software and saved as an stereo lithography (STL) file. Ten specimens were printed with an SLM-type metal 3D printer (SLM group), and 10 more specimens were fabricated by casting the castable patterns output generated by a digital light processing-type resin 3D printer (casting the 3D printed resin patterns [CRP] group). The fit was measured using the silicon replica technique, and 8 points (A to H) were set per specimen to measure the marginal (points A, H) and internal (points B~G) gaps. The differences among the groups were compared using the Mann-Whitney U-test (α=0.05). Results: The mean of marginal fit in the SLM group was 69.67±18.04 ㎛, while in the CRP group was 117.10±41.95 ㎛. The internal fit of the SLM group was 95.18±41.20 ㎛, and that of the CRP group was 86.35±32 ㎛. As a result of statistical analysis, there was a significant difference in marginal fit between the SLM and CRP groups (p<0.05); however, there was no significant difference in internal fit between the SLM group and the CRP group (p>0.05). Conclusion: The marginal and internal fit of SLM is within the clinically acceptable range, and it seems to be applicable in terms of fit.

다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구 (Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods)

  • 정승진;조혜원;정지혜;김정미;김유리
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.211-218
    • /
    • 2019
  • 목적: 본 연구에서는 CAD/CAM 기술로 제작한 4가지 금속하부구조물의 변연 및 내면 적합도를 비교하여 정확도 및 임상적 효용성을 알아보고자 한다. 재료 및 방법: 상악 중절치 레진모형치아를 삭제한 뒤 복제하여 Ni-Cr 합금 표준 모형을 제작하였다. 이를 공초점 현미경방식의 구강 스캐너를 이용해 12개의 STL 파일을 얻었다. CAD 프로그램 상에서 $50{\mu}m$의 시멘트 공간을 부여한 두께 0.5 mm의 금속하부구조물을 디자인하였다. Co-Cr 금속하부구조물은 다음 4가지 방법으로 제작하였다: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). 변연 및 내면 적합도를 측정하기 위해 실리콘 복제법을 이용하였다. 측정한 결과값은 SPSS 통계 프로그램을 이용하여 일원배치분산분석(one-way ANOVA)으로 통계처리하고, 사후검정으로 Scheffe test를 시행하였으며, 5% 유의수준으로 평가하였다(${\alpha}=.05$). 결과: 변연 적합도는 WM군($27.66{\pm}9.85{\mu}m$)과 MS군($28.88{\pm}10.13{\mu}m$)이 RP군($38.09{\pm}11.14{\mu}m$)에 비해 통계적으로 유의하게 작았다. 치경부 적합도는 MS군이 RP군에 비해 통계적으로 유의하게 작았다. 축면 적합도는 WM군과 MS군이 RP군과 SLM군 보다 통계적으로 유의하게 작았다. 절단면 적합도는 RP군이 통계적으로 유의하게 작았다. 결론: Wax pattern milling & Casting, Milling & Sintering법으로 제작한 Co-Cr coping의 변연과 축면에서의 적합도가 더 우수하였다. 모든 군의 Co-Cr coping의 변연, 치경부, 축면 적합도는 임상적으로 허용할만한 범위 안에 있었다.

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권6호
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

도재전장금관을 위한 코핑의 변형에 관한 연구 (A STUDY ON THE DISTORTION OF THE COPINGS FOR CERAMOMETAL CROWNS DURING REPEATED FIRING)

  • 이기홍;정헌영;이선형;양재호
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.706-718
    • /
    • 1997
  • Ceramometal crowns are common restorations in fixed prosthodontics because of their casting accuracy, the high strength properties of the metal, and the cosmetic appearance of porcelain. However, deterioration of the initial fit of the metal coping has been observed after the porcelain firing cycle. The distortion due to repeated firing makes it difficult to fit crown margin and elicits microleakage. The major causes of distortion are the residual stress that accumulate during wax-up, casting, cold work and the induced stress caused by the mismatch of porcelain-metal thermal contraction. This study examined the marginal fit changes of metal copings in relation to repeated firing and the effects of heat treatment that reduce the distortion resulted from residual stress. The marginal changes of the copings that were treated with conventional method and those treated with heat before repeated firing, were evaluated. The metal die which represented preparations of a maxillary central incisor was fabricated, and 45 wax patterns were cast with nonprecious metal alloys. The heat treatment of each group was performed as follows. Group 1(control) : Casting - Devesting - Cold work - Firing Group 2 : Casting - Heat treatment - Devesting - Cold work - Firing Group 3 : Casting - Devesting - Cold work - Reinvesting - Heat treatment - Devesting - Firing The copings were fired 3 times. After each firing, the marginal fit changes were measured with inverted metallurgical microscope at the 4 reference points located at labial, lingual, and both proximal surface. Measurements were compared, and statistically analyzed. The results were as follows ; 1. In all groups, the highest value of marginal fit changes of the copings studied were found after the first firing cycle. 2. When the distortion of each experimental group at the first firing cycle were compared, group 1 exhibited the greatest changes($20-27{\mu}m$), followed by group 2($9-13{\mu}m$), and group 3($8-10{\mu}m$). 3. The copings treated with heat before devesting(group 2) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 4. The copings treated with heat after reinvesting(group 3) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 5. No siginificant differences in marginal fit changes were found between the copings treated with heat before devesting(group 2) and the copings treated with heat after reinvesting(group 3). (p>0.01)

  • PDF

요양병원 간호사의 임종간호경험 (End-of-life Care Experiences of Long-Term Care Hospital Nurses)

  • 여형남
    • 문화기술의 융합
    • /
    • 제9권5호
    • /
    • pp.185-192
    • /
    • 2023
  • 현재 우리나라 요양병원은 노인인구 증가와 함께 지속적으로 증가하고 있다. 요양병원에 입원하는 환자는 주로 만성질환을 가진 노인들로서 장기요양을 목적으로 하기 때문에 요양병원에서 임종하는 경우가 많아 요양병원에서의 임종간호 중요성이 점점 커지고 있다. 이러한 특징에도 불구하고 요양병원 간호사를 대상으로 임종간호에 대한 연구로는 주로 양적연구들로서 임종간호 경험에 대해 심층적으로 파악하기에 제한이 있다. 따라서 본 연구의 목적은 현상학적 방법을 통해 요양병원 간호사의 임종환자 간호경험의 의미가 무엇인지 이해하고 그 현상의 의미를 심층적으로 기술하고 이해하고자 함이다. 본 연구의 대상자는 C 시에 위치한 요양병원에서 6개월 이상 근무하고 있는 간호사 7명을 선정하였다. 연구방법은 심층 인터뷰로 2021년 12월부터 2022년 3월까지 자료를 수집하였다. 인터뷰 자료는 Giorgi의 현상학적 방법으로 분석하였다. 연구 결과 '임종간호에 대한 간호사의 태도', '연명에 대한 양가 감정', '요양병원의 임종간호에 대한 현실', '삶과 죽음에 대한 성찰'으로 나타났다. 따라서 요양병원 간호사의 임종간호 태도를 변화시키고 대처능력을 향상시킬 수 있는 임종간호 보수교육 및 중재 교육프로그램이 개발되어야 할 것으로 사료된다.

유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성 (Fracture load and marginal fitness of zirconia ceramic coping by design and coloration)

  • 신미란;김민정;오상천
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.406-415
    • /
    • 2009
  • 연구목적: 본 연구는 유색 및 백색 지르코니아 세라믹으로 제작된 코핑의 디자인에 따른 지르코니아 세라믹 코핑의 파절 하중과 변연 적합성을 평가한 것으로 그 결과를 임상에 응용하는데 도움을 주고자 하였다. 연구재료 및 방법: CAD/CAM system (Everset, KAVO Dental GmbH, Biberach, Germany)을 이용하여, 80개의 상악 제1 소구치 세라믹 코핑을 제작하되, 1그룹은 전체적으로 균일하게 0.3 mm로, 2그룹은 협면 0.3 mm 설면 0.6 mm, 3그룹은 전체 0.6 mm 균일하게, 4그룹은 협면 0.6 mm 설면 1.0 mm로 디자인하고, 유색 (I) 및 백색 (II) 지르코니아 코핑을 각 그룹당 10개가 되게 하였다. 소성직후와 조정 후 코핑의 변연 적합성을 Video Microscope System (sv-35, Sometech, Seoul, Korea)를 이용하여 100배율로 관찰하였고, 금속 주 모형에 코핑을 강화형 글래스아이오노머 시멘트로 합착 후 Universal Testing Machine (Instron 4467, Norwood, MA, USA)을 이용하여 파절 하중을 측정하여, one-way ANOVA test 를 시행하여 결과를 분석하였다. 결과: 1. CAD/CAM 지르코니아 코핑의 파절 하중은 1그룹, 2와 3그룹, 그리고 4그룹간에 유의성있는 차이를 보였으며 I4, II4의 파절 하중값이 가장 컸다. 2. 코핑의 디자인이 같고 색이 다른 그룹간의 비교에서는 전 그룹 모두 파절 하중값의 유의성은 없었다. 3. 소성 직후 변연 오차 측정값은 I2그룹을 제외한 전 그룹에서 협측 측정점에서 변연오차가 가장 큰 경향을 보였다. 4. 소성 직후 변연 오차 측정값은 I 그룹 지르코니아 그룹에서 그룹별 전체적인 변연적합도를 보았을 때 그룹간에 유의한 차이는 없었다 (P>.05). 5. 소성직후 변연 오차 측정값은 백색 지르코니아 그룹에서 그룹별 전체적인 변연 적합도를 보았을때 II1그룹의 변연 오차가 가장 컸다 (P<.05). 6. 소성직후 변연오차 측정값은 디자인이 같은 그룹의 유색, 백색 비교에서, I1와 II1그룹을 제외한 나머지 그룹에서 백색 지르코니아의 변연 적합도가 더 좋았다 (P<.05). 7. 내면 조정 후에는 색상화 및 지르코니아 코어 디자인에 따른 전 그룹간 변연 적합도의 차이는 없었다 (P>.05). 결론: 지르코니아 코핑 디자인과 색상화에 따른 변연 적합성은 소성 직후에는 다소 차이가 있었으나 내면 조정을 하면 임상 사용에는 무리가 없을 것으로 판단되었고, 파절강도 강화를 위해 코핑의 두께는 가급적 두꺼워야 하나, 가시면 (순면, 협면)의 심미성(반투명성)을 고려할 경우 가시면을 0.3 mm로 얇게 해도 파절 강도에 큰 영향을 주지 않는 것으로 사료되었다.