• Title/Summary/Keyword: Diaphragm system

Search Result 214, Processing Time 0.03 seconds

A Study on the Worst Stress Condition Test Evaluation of Blowers for Small Stationary Fuel Cell System (소용량 건물용 연료전지시스템 블로워의 가혹조건 평가에 관한 연구)

  • Kim, Kangsoo;Lee, Deokkwon;Lee, Jungwoon;Kim, Eunjung;Kim, Inchan;Kim, Younggyu;Shin, Hunyong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.34-40
    • /
    • 2012
  • The fuel cell is one of the renewable energy sources. And it is a new source of energy that can be applied to various fuels and continuously supported by the excellent city-gas infrastructure. It is important to improve performances and reliabilities, and reduce the cost of fuel cell systems for commercialization. And, some safety performances of blower domestically produced are evaluated and some improvements are researched to save the cost of fuel cell systems. In this paper, the performance and worst stress condition of blowers are evaluated in operating environment similar to the fuel cell systems. Actually, the correlation of flow, leakage and thermal behavior are evaluated in the worst stress condition at $70^{\circ}C$ and, some major factors of blower degradation such as a motor deterioration, material and structures of the outlet are examined.

Effect of inhibition on Browning and Microbial Growth of Minimally Processed Lettuce (최소가공 처리에 의한 양상추의 갈변 및 미생물 증식억제 효과)

  • Cha Hwan-Soo;Kim Soon-1m;Kim Byeong-Sam;Kim Sang-Hee;Park Seon-Ju;Cho Han-Sun;chd Hye-Yeon
    • Food Science and Preservation
    • /
    • v.11 no.3
    • /
    • pp.331-335
    • /
    • 2004
  • This study was carried out to improve quality of minimally processed lettuce with various treatments. The treatments for preventing enzymatic browning were using different chemical immersion solutions and controlling microbial growth were using chlorine, electrolyzed water, and organic acid. The solution with ascorbic acid 1$\%$ and citric acid 1 $\%$ showed a positive effect on antibrowning of minimally processed lettuce. In the inhibition of microorganisms growth, 200 ppm NaCIO solution was more effective than fermented pollen solution and Na-dichloroisocyanurate solution. In electrolyzed water system, no-diaphragm system showed inhibitory effect of microorganisms growth. Also, total microorganisms count of minimally processed lettuce with ascorbic acid and citric acid solution was lower by about 4 log cycle after 4 days storage at l0$^{\circ}C$.

A Study for Failure Examples of Emission Gas Recirculation and Air Control and Catalyzed Particulate Filter System in Diesel Engine Vehicle (디젤엔진 자동차의 EGR 및 공기 제어와 CPF 장치에 관련된 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Young Suk;Youm, Kwang Wook;You, Chang Bae;Kim, Sung Mo;Lim, Ha Young;Ahn, Ho Cheol;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.78-83
    • /
    • 2018
  • The purpose of this paper is to study for failure examples of emission gas recirculation and air control and catalyzed particulate filter system in diesel engine vehicle. The first example, the researcher found the fact that the much engine oil came into the intake manifold causing diaphragm damage of EGR valve. The engine oil entered into combustion chamber of engine so that a car emit the polluted exhaust gas when driving. The second example, the researcher certified the sticking phenomenon of carbon and foreign substance with the throttle flap so that the exhaust fumes discharged exhaust port. The third example, the regeneration function don't activated to not detect the temperature of exhaust gas because of damage in the sensor. Thus, the researcher must meticulously manage his car not in order to take place the problem of environmental pollution.

$\textrm{NO}_2$ Absorption and Physiological Response of Lettuce in a Semi-closed Plant Production System (부분 밀폐형 식물생산시스템에서 상추의 $\textrm{NO}_2$ 흡수 및 생육반응)

  • Jung Eek Son;Jong Seok Park
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.207-212
    • /
    • 2001
  • The environmental characteristics, absorption rate of NO$_2$, physiological response, and quality of lettuces were examined in a semi-closed plant production system consisted of human and plant modules. Leaf lettuces were transplanted to 10-cm diameter pots at 4-to 5-leaf stage, and grown in a gas-fumigated plant module. Air containing NO$_2$was circulated 10 min-ON/ 20 min-OFF between the human and plant modules by a diaphragm. At 0.13, 0.30, and 0.45 $\mu$mol.mol$^{-1}$ NO$_2$, NO$_2$ decrements in the chamber during the 10 min were 0.040, 0.109, and 0.149 $\mu$mol.mol$^{-1}$ , respectively. The NO$_2$absorption rate of the plants was estimated to be 0.078 $\mu$mol.mol$^{-1}$ .m$^{-2}$ .min$^{-1}$ at 0.45 $\mu$mol.mol$^{-1}$ NO$_2$ was less than that of the control plant at 4th and 5th days, whereas the respiration rate was the same. The lettuce grown at 0.45 $\mu$mol.mol$^{-1}$ NO$_2$ had similar leaf length, leaf area, dry and fresh weights, and quality to that grown without NO$_2$.

  • PDF

Development of VOCs Treatment Technology using High Efficiency Hybrid System with Multi-Scrone (멀티 선회류식 세정장치를 이용한 고효율 하이브리드 VOCs 습식처리 SYSTEM 개발)

  • Lim, Seong-Il;Kim, Nor-Jung;Kim, Sun-Mi;Lee, Seong-Hun;Kim, Sun-Uk;Chang, Won-Seok;Park, Dae-Won;Kim, Lae-Hyun;Kim, Jae-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.491-498
    • /
    • 2009
  • We studied to develop high-efficiency removal system of odor and VOCs(Volatile Organic Compounds) from environmental infrastructure facilities and oil refineries, painting facilities and so on. It can replace RTO and RCO. We tried an removal experiment for VOCs (toluene, xylene, benzene, MEK(methyl ethyl ketone), ethanol, formalin etc. and odor compounds (hydrogen sulfide, etc.). In process, as pre-treatment we used the scrubber with vortex flow (Multi-scrone) to remove the hydrophilic VOCs and as post-treatment, used fibrous bio-filter to remove the hydrophobic VOCs. This hybrid system remove with high efficiency both the hydrophilic VOCs and hydrophobic VOCs. And we tried to make this system to be compact. In experiment using Multi-scrone, contact time is 2~3 seconds and absorption scrubbing water is diaphragm-type electrolysis water. hydrophilic VOCs like ethanol and relatively hydrophilic odor compounds like hydrogen sulfide is excellent, these substances has been removed almost completely, respectively 95~99%, 93~97%. And for MEK, formalin also Showed a high removal efficiency, respectively 78~90%, 72~85%. But in experiment using Multi-scrone, the hydrophobic VOCs like BTX showed a low removal efficiency, respectively 16~22%, 12~18%, 8~16%. In hydrophobic VOCs, toluene removal experiment using fibrous bio-filter, early efficiency was low but after 10days, adaptation period showed high efficiency 85~95%. but in the mixed phase, toluene and MEK efficiency reduced 5~10%. this show microorganism treat first MEK easy to remove. The removal efficiency for MEK using the fibrous biofilter was stable, 80~92%. This hybrid system is also high economical efficiency for RTO. This system reduce more than 50% the cost of equipment and maintenance. As a result, we expect this technology is in the limelight as high efficiency treatment of VOCs in mid-low price.

A Case of Persistent Hiccup in a Patient with Non-small Cell Lung Cancer (비소세포폐암 환자에서 발생한 지속성 딸꾹질 1예)

  • Park, Hye Sung;Sim, Yun Su;Lim, So Yeon;Jo, Jung Youn;Kwon, Sung Shin;Roh, Sun Hee;Kim, Yoo Ri;Chun, Eun Mi;Lee, Jin Hwa;Ryu, Yon Ju;Song, Dong Eun;Moon, Jin Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • A hiccup is caused by involuntary, intermittent, and spasmodic contractions of the diaphragm and intercostal muscles. It starts with a sudden inspiration and ends with an abrupt closure of the glottis. Even though a hiccup is thought to develop through the hiccup reflex arc, its exact pathophysiology is still unclear. The etiologies include gastrointestinal disorders, respiratory abnormalities, psychogenic factors, toxic-metabolic disorders, central nervous system dysfunctions and irritation of the vagus and phrenic nerves. Most benign hiccups can be controlled by traditional empirical therapy such as breath holding and swallowing water. However, though rare, a persistent hiccup longer than 48 hours can lead to significant adverse effects including malnutrition, dehydration, insomnia, electrolyte imbalance, and cardiac arrhythmia. An intractable hiccup can sometimes even cause death. We herein describe a patient with non-small cell lung cancer who was severely distressed by a persistent hiccup.

A Case of Atypical Pathogen Pneumonia, associated with Recurrent into Diffuse Pneumonic Consolidation (재발성 경과를 취한 비정형 병원균주 폐렴 환자 1예)

  • Oh, Jong-Kap
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.391-400
    • /
    • 2011
  • Pneumonia is an infection of the lungs and respiratory system and can be classified by a variety of factors such as infectious agents, etiology, infection area, and other criteria. From a 46-year-old male, who was suspected of being infected with atypical pathogen pneumonia and underwent such tests as serological testing, examination of sputum, urine examination, parasite examination, bronchoscopy, needle biopsy and so on, no significant abnormality was found. This patient also showed no specific symptoms like auscultatory abnormalities, high fever, nonproductive cough, muscle stiffness, sputum production, dyspnea. Prescription of broad-spectrum oral antibiotics and ant-parasitic didn't seem to be effective against bacterial and atypical pathogen. The patient's condition alternately repeated between natural cure and recurrence. The average healing process during which scarring, nodule recurrence and disappearance on the lungs happened was about 20 days. Chest radiography and chest high resolution computerized tomographic scans(HRCT scan) was performed to depict parenchymal aberrations and demarcate the extent and distribution of atypical pathogen pneumonia. As a result, chest radiography did not show the specific symptoms, whereas areas of opacity (seen as white) which represent consolidation were revealed in chest HRCT scan. This indicates that only chest radiography is not that useful for early diagnosis of atypical pathogen pneumonia in patients, since it can't show exactly what the symptom is because of the barriers such as diaphragm, liver, and spine. Therefore, it is desirable that chest HRCT should be used in the diagnosis to compare with the results of chest radiography. Here, report with literature investigations the case of recurrent atypical pathogen pneumonia.

Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame (모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가)

  • Lee, Sang Sup;Park, Keum Sung;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.471-481
    • /
    • 2015
  • Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.

Stabilization Performance Evaluation of Filter(pH) Using Ionic Water Generator (이온수기 필터(pH)의 안정화 성능평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. And there are various types of water. Ionic water generator is a system with special function, and can be classified as a medical device and should be manufactured after approval from the Food and Drug Administration. Basically ionized water is different from the packaged and stored water. When the tap water or ground water passes through the various filters of ionic water generator, it turns to the purified water of pH7 ~ 7.5 and we can electrolyze that water into anion and cation by diaphragm. And in negative electrode side, we can get alkaline water with calcium ($Ca^+$), potassium ($K^+$), magnesium ($Mg^+$), sodium ($Na^+$) for body. In general, we can change pH value from 5 to 9 of ionizer by controlling the level of electrolysis voltage in the ionizer. In general, 1stage (pH8), 2stage (pH8.5), 3stage (pH9), 4stage (pH9.5) are used as the alkaline ionized water, -1Stage (pH6.0), -2 stage (pH5.0) are used as the acidic water. But in early stage, the water that passed through filter was weakly alkaline water and that was problem. Therefore, when filter condition is stable, the pH and ORP value of water is different with the early one. the initial setting pH value of the ionizer was confirmed that changes significantly. In order to resolve this problem we need to wash filter for some period time and neutralize by acidification treatment of the filter.

Preparation and Evaluation of Hybrid Porous Membrane for the Application of Alkaline Water Electrolysis (알칼리 수전해 적용을 위한 하이브리드 다공성 격리막 제조 및 특성평가)

  • Han, Seong Min;Im, Kwang Seop;Jeong, Ha Neul;Kim, Do Hyeong;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.31 no.6
    • /
    • pp.443-455
    • /
    • 2021
  • In this study, polyphenylene sulfide (PPS) was used as a support and a separator was manufactured using polysulfone and inorganic additives to manufacture a separator with low membrane resistance for application of an alkali water electrolysis system, and then the effect on the thickness and porosity of the support was analyzed. The PPS felt used as a support was compressed with variables of temperature (100℃, 150℃, 200℃) and pressure (1 ton, 2 tons, 3 tons, 5 tons) to adjust the thickness. A porous separator could be manufactured by preparing a slurry with polysulfone using BaTiO3 and ZrO2 which have high hydrophilicity and excellent alkali resistance as inorganic particles and casting the slurry on a compressed PPS felt. Changes in morphology of the separator according to compression conditions were confirmed through an electron scanning microscope (SEM). After that, the porosity was calculated, and the thickness and porosity tended to decrease as the compression conditions increased. Various characteristics were evaluated to confirm whether it could be used as a separator for water electrolysis. As a result of measuring the mechanical strength, it was confirmed that the tensile strength gradually increased as the compression conditions (temperature and pressure) increased. Finally, it was confirmed that the porous separator manufactured through the alkali resistance test has excellent alkali resistance, and through the IV test, it was confirmed that the membranes compressed at 100℃ and 150℃ had a lower voltage and improved performance than the existing uncompressed membrane.