• Title/Summary/Keyword: Diaphragm frequency

Search Result 89, Processing Time 0.029 seconds

Optical Microphone Incorporating a Dual-Core Multimode Fiber Block and a Reflective Micromirror (반사형 마이크로 미러와 다중모드 광섬유를 이용한 광마이크로폰)

  • Song, Ju-Han;Lee, Sang-Shin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.263-266
    • /
    • 2006
  • An optical microphone was developed using a dual-core multi-mode fiber block and a membrane type micromirror. The fiber block serves as a compact optical head, and the micromirror as a reflective diaphragm. The micromirror is designed to be suspended through a silicon bar connected t a frame, allowing for displacement induced by acoustic waves. The optical head is implemented by integrating two multi-mode fibers in a single block, and used to transfer light signals between it and the diaphragm. For the assembled microphone, its static characteristics were observed to reveal the operating point defined as the optimum distance between the optical head and the diaphragm. And its dynamic response was tested to exhibit a frequency bandwidth of 3 kHz with the variation of $\sim5dB$.

The Acute Effect of Trimetazidine on the High Frequency Fatigue in the Isolated Rat Diaphragm Muscle

  • Emre, Mustafa;Karayaylali, Lbrahim;San, Mustafa;Demirkazik, Ayse;Kavak, Servet
    • Archives of Pharmacal Research
    • /
    • v.27 no.6
    • /
    • pp.646-652
    • /
    • 2004
  • The objective of this study was to determine the acute effect of trimetazidine (TMZ) on the pre-fatigue, fatigue and post-fatigue contractile characteristics and tension-frequency relationships of isolated rat diaphragm muscle. Muscle strips were taken from the ventral-costal aspects of the diaphragm muscle of rats killed by decapitation. The muscle strips were suspended in organ baths containing Krebs solution, with a gas mixture of 95% $O_2$ and 5% $CO_2$ at $37^{\circ}C$ and pH 7.35-7.45. After determining the thermoregulation and optimum muscle length the muscles were subjected to direct supramaximal stimulation with 0.05 Hz frequency square pulses for periods of 0.5 msec to obtain control values. After adding $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine solution to the respective bath media, the contractile parameters of the muscles were recorded. The contractile parameters were also recorded for both the trimetazidine and tri-metazidine-free media after application of the high frequency fatigue protocols. Later, the tension-frequency relationship was determined by applying stimulating pulses of 10, 20, 50 and 100 Hz to the muscle strips. Whilst the twitch tension obtained from the $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine media showed numerical increases compared to that of the controls, these were not statistically significant (p>0.05). The contraction time exhibited a dose dependent increase (p<0.001), whilst the contraction and relaxation rates did not differ significantly. The isometric contraction forces obtained with the different stimulating frequencies showed a significant increase in the tetanic contraction only at 100 Hz (p<0.05). A comparison of the pre- and post-fatigue twitch tensions in the trimetazidine media showed the post- fatigue twitch tensions to be significantly higher than those of the pre-fatigue contraction forces (p<0.05). In the $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine media the increases in the post-fatigue contraction force were 22 and 30%, respectively. These results demonstrated that in isolated rat diaphragm muscle, TMZ significantly limited the mechanical performance decrease during fatigue. It is our opinion that trimetazidine contributed to the observed fatigue tolerance by eliminating the factors of fatigue, due to preservation of intracellular calcium homeostasis, provision of the ATP energy levels needed by ATPase dependent pumps and especially by keeping the intracellular pH within cer-tain limits.

Optical Microphone Based on a Reflective Micromirror Diaphragm (반사형 마이크로 미러를 이용한 광마이크로폰)

  • Song, Ju-Han;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.4
    • /
    • pp.366-370
    • /
    • 2006
  • An optical microphone incorporating a reflective diaphragm and a fiber-optic head was demonstrated. The diaphragm was made of a micromirror membrane which is suspended by a silicon bar connected to a frame, allowing fer a displacement induced by acoustic waves. A compact, simple optical head was implemented by exploiting a single multimode fiber. For the assembled microphone, the static characteristics were investigated to find the operation point defined as the optimum distance between the head and the diaphragm, and a flat frequency response with a variation of $\sim$2dB for the range of up to 2 kHz was accomplished.

Hybrid Rocket Instability II (하이브리드 로켓 불안정성 II)

  • Lee, Jung-Pyo;Rhee, Sun-Jae;Kim, Young-Nam;Moon, Hee-Jang;Sung, Hong-Gye;Kim, Jin-Gon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.86-90
    • /
    • 2012
  • In this paper, the combustion instabilities which may occur in the hybrid rocket were studied. The rocket combustor where the vortexes can be generated was designed, and the experiments were performed. The investigations about characteristics on the presence of the diaphragm, the length of the fuel, the diameter of the fuel port, the diameter of the diaphragm, the diameter of the nozzle throat, and the variation of the Ox massflow rate were conducted. The main resonant frequency of the combustion pressure is regarded by the Vortex shedding mode, and it is considered that the other resonant frequency of the pressure fluctuation is hybrid low frequency, or helmholtz mode.

  • PDF

Clinical evaluation and surgical intervention for diaphragmatic eventration mimicking peritoneopericardial hernia in a cat

  • Min-Jung Ko;Kyoung-Min Song;Hun-Young Yoon
    • Journal of Veterinary Science
    • /
    • v.25 no.2
    • /
    • pp.19.1-19.6
    • /
    • 2024
  • A 2-year-old spayed female British Shorthair cat presented with an increased frequency and duration of cough since infant period. Based on radiographic, ultrasonographic, and computed tomography findings, peritoneopericardial diaphragmatic hernia was considered so that repair surgery was planned. During celiotomy, lax diaphragm was identified instead of defect. Transabdominal diaphragmatic plication was performed to resolve lax diaphragm and to prevent recurrence by overlapping relatively normal part of diaphragm. Diagnosed with diaphragmatic eventration postoperatively, the cat showed improvement in clinical signs and imaging results. Transabdominal diaphragmatic plication is a suitable treatment; the patient maintained normally during a 14-month follow-up period.

Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm (슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측)

  • Kim, Hyun-Kab;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.109-115
    • /
    • 2016
  • In this paper, In this paper, we use two methods to compare the slim speakers. That way, the diaphragm scan using laser and diaphragm photographed using a thermal imaging camera. Slim speaker has the structure of a flat plate type. Break-up mode by this characteristic is displayed in a larger size. Further, since the installation space is narrow, it has limited moving coil cooling. As a result, the break-up mode slim speakers, a significant impact on quality. In this study, try to connect the break-up mode of the diaphragm, the heat transfer mode of the diaphragm. Experiment for comparison, a two-step. The first step is to measure the divided vibration through the vibration plate scan. The second step measures the diaphragm photographed using a thermal imaging camera. Then, compare the results of both of the same frequency. Thus, comparing the heat transfer pattern and the pattern of break-up mode. Tend to be analysis of break-up mode from the pattern comparison, and document for the optimum design.

Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness (극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Hwang, In-Sung;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

Fabrication of a Thermopneumatic Valveless Micropump with Multi-Stacked PDMS Layers

  • Jeong, Ok-Chan;Jeong, Dae-Jung;Yang, Sang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.137-141
    • /
    • 2004
  • In this paper, a thermopneumatic PMDS (polydimethlysiloxane) micropump with nozzle/diffuser elements is presented. The micropump is composed of nozzle/diffuser elements as dynamic valves, an actuator consisting of a circular PDMS diaphragm and a Cr/Au heater on a glass substrate. Four PDMS layers are used for fabrication of an actuator chamber, actuator diaphragm by a spin coating process, spacer layer, and nozzle/diffuser by the SU-8 molding process. The radius and thickness of the actuator diaphragm is 2 mm and 30 ${\mu}{\textrm}{m}$, respectively. The length and the conical angle of the nozzle/diffuser elements are 3.5 mm and 20$^{\circ}$, respectively. The actuator diaphragm is driven by the air cavity pressure variation caused by ohmic heating and natural cooling. The flow rate of the micropump in the frequency domain is measured for various duty cycles of the square wave input voltage. When the square wave input voltage of 5 V DC is applied to the heater, the maximum flow rate of the micropump is 44.6 ${mu}ell$/min at 100 Hz with a duty ratio of 80% under the zero pressure difference.

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Cho, Hee-Chan;Yi, Seung-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.556-561
    • /
    • 2008
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small and constant at low frequency region and shows about 70 dB at 10 kHz. However, in case of a compressively stressed composite diaphragm, the SPL of the fabricated microspeakers shows higher output pressure than those of a tensile-stressed diaphragm. It produces more than 66 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with $20V_{peak-to-peak}$, sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone. From the experimental results, it is superior to have a compressively composite diaphragm in order to produce a high SPL in piezoelectric microspeaker.

A Telemetry Silicon Pressure Sensor of LC Resonance Type (LC공진을 이용한 원격측정용 압력센서의 제작 및 실험)

  • Kim, Hak-Jin;Kim, Soon-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1872-1874
    • /
    • 2001
  • This paper presents an implantable telemetry LC resonance-type pressure sensor to measure the cerebral ventricle pressure. The sensor consists of an inductor and a capacitor. The LC resonant circuit consists of the sensor and an external antenna coil that are coupled magnetically. The resonance frequency of the circuit decreases as the applied pressure increases the capacitance of the sensor. The sensor is designed in consideration of the biocompatibility and long lifetime for continuous monitoring of the ventricle pressure. The sensor is simple to fabricate and small in comparison with others reported previously. The inductor is fabricated by electroplating and the variable capacitor is constructed with a flexible p+ diaphragm. Also, the deflection of the diaphragm, the variation of the capacitance and the resonance frequency are analyzed and calculated.

  • PDF