• 제목/요약/키워드: Diagnostic ultrasound

검색결과 431건 처리시간 0.024초

플랭크 운동이 비대칭 골반 앞기울임을 가진 대상자의 복부근육 두께 변화에 미치는 영향 (Effect of Plank Exercise on the Abdominal Muscle Thickness of Subjects with Asymmetric Pelvic Anterior Tilt)

  • 박강희;김형수
    • 대한통합의학회지
    • /
    • 제6권3호
    • /
    • pp.25-32
    • /
    • 2018
  • Purpose : This study investigated the effects of different types of plank exercise on abdominal muscle thickness in subjects with asymmetric pelvic anterior tilt. Methods : Participants with a diagnosis of pelvic anterior tilt were divided into an experimental group (n=12) and a control group (n=13). The thicknesses of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles were measured using an ultrasound diagnostic apparatus. The data were analyzed using an SPSS (Ver. 21) program. Results : In the experimental group, there was a significant difference in the thicknesses of the left and right muscles in the standing and elbow plank exercises (p<.05). All the muscle thicknesses increased significantly during the plank exercises(elbow plank, right-side plank, and left-side plank) as compared with those in the standing position (p<.05). In addition, the side-plank exercise resulted in significantly higher muscle thickness of the supported side (p<.01, p<.001). Conclusion : These findings suggest that asymmetric exercise should be applied to the change of the left and right muscles of the abdominal when applying plank exercise according to pelvic anterior tilt.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Changes in Abdominal Muscle Thickness and Balance Ability on Plank Exercises with Various Surfaces

  • Kang, Kyung-Woo;Son, Sung-Min;Ko, Yu-Min
    • The Journal of Korean Physical Therapy
    • /
    • 제28권5호
    • /
    • pp.264-268
    • /
    • 2016
  • Purpose: This study was conducted to investigate the effects on muscle thickness and balance ability after performing plank exercise on various surface types. Methods: In this study, there were thirty healthy participants. Participants were randomly distributed into three groups, a control group (n=10), sling group (n=10), and ball group (n=10). All participants performed plank exercises three times a week for four weeks. Plank exercises consisted of five sets of 30 seconds each with a one minute break between each set. Muscle thickness of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) was measured using an ultrasound diagnostic apparatus and balance was measured using I-balance. Results: Evaluation of muscle thickness revealed that the IO and EO muscle of the ball group changed significantly relative to the control group (p<0.05). However, there were no significant changes in balance. Conclusion: The results revealed that performing plank exercise on a ball is more effective among various types of surfaces.

전형적인 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기 (Harmonic generation emitted from ultrasonic contrast agent in response to a typical diagnostic ultrasound)

  • 최민주;강관석;팽동국;임성민
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.373-378
    • /
    • 2004
  • 하모니 영상은 초음파의 비선형 전파 과정에서 발생된 하모닉 성분을 영상화 한다. 하모닉 영상은 초음파에 비선형적으로 반응하는 초음파 조영제를 사용하여 하모닉 성분의 발생을 최대화 하고 있다. 일반적으로 현재 임상적으로 사용되는 하모닉 영상은 2차 고주파 성분을 사용한 것을 의미한다. 2차 하모닉 영상은 주파수의 상승으로 공간 분해능이 향상된다. 초음파 조영제를 이용하는 경우 서브 하모닉, 울트라 하모닉의 발생도 유의할 것으로 기대되지만 이에 대한 연구는 거의 없는 실정이다. 서브 하모닉은 상대적으로 2차 하모닉보다 전파 과정에서 감쇠 효과가 작기 때문에 심부의 영상에 유리하다 서브 하모닉 및 울트라 하모닉 성분 검출은 초음파 변환기의 대역폭에 대한 제한을 2차 하모닉에 비해 상대적으로 덜 받는다. 본 연구에서는 진단용 초음파에 의해 초음파 조영제에서 방사하는 하모닉 성분의 크기를 시뮬레이션 하였다. 수치해석은 Gilmore Equation을 이용하였으며, 초음파 조영제의 탄성 효과는 무시하였다. 초음파 조영제의 크기와 초음파의 MI에 따라 하모닉 성분의 크기를 정량적으로 비교하고, 서브 및 울트라 하모닉 영상의 구현에 대해 토의하였다.

  • PDF

A TRUS Prostate Segmentation using Gabor Texture Features and Snake-like Contour

  • Kim, Sung Gyun;Seo, Yeong Geon
    • Journal of Information Processing Systems
    • /
    • 제9권1호
    • /
    • pp.103-116
    • /
    • 2013
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease accurate detection of prostate boundaries in transrectal ultrasound(TRUS) images is required. This is a challenging and difficult task due to weak prostate boundaries, speckle noise and the short range of gray levels. In this paper a method for automatic prostate segmentation in TRUS images using Gabor feature extraction and snake-like contour is presented. This method involves preprocessing, extracting Gabor feature, training, and prostate segmentation. The speckle reduction for preprocessing step has been achieved by using stick filter and top-hat transform has been implemented for smoothing the contour. A Gabor filter bank for extraction of rotation-invariant texture features has been implemented. A support vector machine(SVM) for training step has been used to get each feature of prostate and nonprostate. Finally, the boundary of prostate is extracted by the snake-like contour algorithm. A number of experiments are conducted to validate this method and results showed that this new algorithm extracted the prostate boundary with less than 10.2% of the accuracy which is relative to boundary provided manually by experts.

Use of Omega-3 Polyunsaturated Fatty Acids to Treat Inspissated Bile Syndrome: A Case Report

  • Jun, Woo Young;Cho, Min Jeng;Han, Hye Seung;Bae, Sun Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제19권4호
    • /
    • pp.286-290
    • /
    • 2016
  • Inspissated bile syndrome (IBS) is a rare condition in which thick intraluminal bile, including bile plugs, sludge, or stones, blocks the extrahepatic bile ducts in an infant. A 5-week-old female infant was admitted for evaluation of jaundice and acholic stool. Diagnostic tests, including ultrasound sonography, magnetic resonance cholangiopancreatography, and a hepatobiliary scan, were not conclusive. Although the diagnosis was unclear, the clinical and laboratory findings improved gradually on administration of urodeoxycholic acid and lipid emulsion containing omega-3 polyunsaturated fatty acids (PUFAs) for 3 weeks. However, a liver biopsy was suggestive of biliary atresia. This finding forced us to perform intraoperative cholangiography, which revealed a patent common bile duct with impacted thick bile. We performed normal saline irrigation and the symptom was improved, the final diagnosis was IBS. Thus, we herein report that IBS can be treated with omega-3 PUFAs as an alternative to surgical intervention.

Evaluation and Management of Antenatal Hydronephrosis

  • Hong, Young Kwon;Lee, Jun Ho
    • Childhood Kidney Diseases
    • /
    • 제19권1호
    • /
    • pp.8-13
    • /
    • 2015
  • Antenatal hydronephrosis (ANH) is one of the most common abnormal findings detected on prenatal ultrasound (US), and it has been reported in 1-5% of all pregnancies. The likelihood of significant postnatal pathologic abnormality in the urinary tract correlates with the degree of anterior-posterior diameter (APD) according to the gestational age. Detection of urologic anomalies prenatally permits fetal interventions that avoid complications in rare cases of bladder outlet obstruction with oligohydramnios even though their final benefits still remain controversial. There is no clear consensus on the extent and mode of postnatal imaging after a diagnosis of ANH. US is the mainstay of the postnatal evaluation and helps guide further testing with voiding cystourethrography (VCUG) and diuretic renography. Although most algorithms continue to recommend generous VCUG for identification of lower urinary tract anomalies, VCUG may be safely reserved for high grade ANH cases or any grade of ANH with dilated distal ureter without increasing the risk of urinary tract infection (UTI). There are conflicting studies about efficacy of postnatal prophylactic antibiotics. It still seems reasonable to consider use of a prophylactic antibiotic to prevent infant UTIs in high-risk populations, such as females and uncircumcised males with high grades of hydronephrosis, hydroureteronephrosis, or vesicouretral reflux.

간동맥 색전술과 간엽 절제술로 치료한 영아 간내 혈관내피종 1례 (A Case of Infantile Hemangioendothelioma of the Liver Treated with Hepatic Embolization and Lobectomy)

  • 김재선;문수경;윤혜선;이태석
    • Clinical and Experimental Pediatrics
    • /
    • 제48권6호
    • /
    • pp.660-664
    • /
    • 2005
  • 저자들은 신생아 시기에 심부전 증세를 보인 간내 혈관내피종 환아에서 내과적 치료와 간동맥 색전술 후 호전을 보이지 않아 간좌엽 절제술을 시행하여 치료한 1례를 경험하였기에 보고하는 바이다.

초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치- (Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System-)

  • 백광렬;안영복
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.139-146
    • /
    • 1986
  • 본 논문은 tms 32010이라는 디지탈 신호 처리용소자를 사용하여 초음하 펄스 도플러 장치를 구현한 것이다. 도플러 장피란 초음파 신호의 송수신 과정에서 발생하는 도플러 효과를 이용하여 혈류의 속도를 측정하는 장치이다. 한 점에서의 속도를 측정하는 단일채널 도플러 장치에서는 실시간 고속 푸리에 변환기를 구현하여 도플러 주하수의 스펙트럼을 측정함으로서 혈류속도를 측정하며 초음파 빔의 일직선상에서의 여러점을 동시에 측정하는 다중채널 도플러 장치에서는 영점교차검출기를 구현하여 평균주파수를 측정하였다. 자중채널 장치는 직렬처리법을 사용하여 하드웨어를 간단히 하였으며 8점에서의 속도를 측정할 수 있도록 하였다.

  • PDF

개에서 복강내 잔존한 거즈 이물의 진단영상 (Diagnostic Imaging Features of Abdominal Foreign Body in Dogs; Retained Surgical Gauze)

  • 최지혜;김계동;계서연;장재영;최희연;윤정희
    • 한국임상수의학회지
    • /
    • 제28권1호
    • /
    • pp.94-100
    • /
    • 2011
  • This study was performed to describe the radiographic and ultrasonographic features of retained surgical gauze known as gossypiboma in 9 dogs. Female dogs (n = 8) were at higher risk and seven out of the eight cases had a history of ovariohysterectomy. Seven dogs were symptomatic and the most common clinical signs were vomiting, anorexia, and inertia. A palpable abdominal mass was detected in six dogs. Radiographic signs included a localized abdominal mass with soft tissue density (n = 7) or a mass containing speckled gas (n = 1). Ultrasonography showed a hypoechoic mass with a hyperechoic center (n = 4), or a homogeneous hypoechoic mass (n = 3). The remaining dogs (n = 2) showed an intestinal wall surrounding a hyperechoic center. Regardless of the characteristics of a mass, an acoustic shadowing was accompanied from the center of a mass in all dogs. Ultrasonography also revealed complications such as adhesion between a mass and adjacent organs, and peritonitis and intestinal obstruction around a mass. The gossypiboma can be considered when a hypoechoic mass accompanying a hyperechoic center with acoustic shadowing is observed on ultrasound examination.