개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발 (A portable electronic nose (E-Nose) system using PDA device)

  • 양윤석;김용신;하승철;김용준;조성목;표현봉;최창억
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구 (Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR))

  • 황준호;정재호;김현수;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제17권9호
    • /
    • pp.99-106
    • /
    • 2017
  • 본 연구는 진단용 검출기가 결함이 발생하는 경우 환자의 방사선 피폭과 영상의 화질에 영향을 줄 수 있다는 점에 착안하여 실험을 진행하였고 선량분석을 통해 검출기 성능을 신호 대 잡음비와 대조도 대 잡음비로 평가하였다. 선량계, 조직등가팬텀을 이용해 흡수선량과 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 실험방법은 팬텀 후면에 부착하여 나온 선량 값과 검출기 뒤에 부착한 선량 값이 일치하는지를 비교하였고 두개부 흉부 복부의 조건을 각각 75 kVp 25 mAs, 110 kVp에 8 mAs, 80 kVp에 20mAs로 설정하고 검사하였다. 그 결과 검출기의 뒤쪽에 부착한 선량값은 0.004 mGy, 0.006 mGy, 0.003 mGy로 나타났고, 팬텀 후면은 0.006 mGy, 0.016 mGy, 0.017 mGy로 차이가 있었다. 두 값을 일치시키기 위해서 조건이 증가하였고 신호 대 잡음비와 대조도 대 잡음비는 88.32, 88.10, 4.09, 1.63, 87.94, 79.97에서 93.87, 93.75, 4.91, 4.03, 92.02, 84.92로 증가하였다. 본 연구를 통해 검출기가 노후화 되는 경우 기기의 수명단축과 환자의 선량증가의 원인이 되었으며 또한 영상화질의 개선효과도 미비하다는 것을 알 수 있었다.

Artificial Insemination with Low-Dose Semen does not affect Swine Reproductive Performances

  • Chung, Ki-Hwa;Lee, Il-Joo;Sa, Soo-Jin;Kim, In-Cheul;Jung, Byeong-Yeal;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • 제37권4호
    • /
    • pp.263-267
    • /
    • 2013
  • Pig producers have been shown keen interest of the number of spermatozoa in a semen dose since pig artificial insemination introduce. However, determining the minimal number of spermatozoa need per AI without detrimental effect on overall reproductive performances is not an easy question to answer. To increase the efficiency of semen utilization in pig AI, optimum number of spermatozoa per dose needed to determine. The objective of this study was to determine the reproductive performance and factors that affect on-farm application of low-dose semen insemination in sows. Data were collected from Darby Genetics AI studs from 4th of June to 7th of July, 2012 (n=401). The numbers of parturition were 84, 234 and 83 in sows inseminated with doses of $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ spermatozoa in 100ml extender, respectively. There were no significant differences on reproductive performances such as gestation period, total born, total born alive, stillbirth and mummy in sows inseminated with different semen doses. The average number of born alive was 10.5, 11.0 and 10.4 from sows inseminated with $1.5{\times}10^9$, $2.0{\times}10^9$ and $2.5{\times}10^9$ sperms, respectively. Also, number of spermatozoa per dose did not affect litter size (p>0.10). There were no significant differences of maternal genetic line difference on gestation period, total number born, number born alive, born dead and mummy. The estimated correlation coefficients of the different semen doses with total number born, number born alive, born dead and mummy were r=-0.00, -0.01, 0.02 and 0.02, respectively. Taken together, the result of this study suggested that when semen was appropriately inseminated after induced ovulation, insemination with low-dose ($1.5{\sim}2.0{\times}10^9$) semen dose not adversely affect sow's fertility.

$^{18}F$-FDG PET/CT 검사에서 이뇨제 사용여부에 따른 $^{18}F$-FDG 배설 특성 (Characteristic of $^{18}F$-FDG Excretion According to Use Diuretics in $^{18}F$-FDG of PET/CT)

  • 장동근;양승오;이상호;배종림;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.151-156
    • /
    • 2012
  • $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG)는 상당한 양의 방사능이 신장과 비뇨기계에 저류 되어 영상의 질을 저하시키고 진단 성능을 저하시킨다. 이러한 $^{18}F$-FDG의 비뇨기계 저류를 막기 위해 이뇨제를 사용하여 검사를 진행하게 된다. 이때 사용되는 이뇨제가 영상에 미치는 영향과 $^{18}F$-FDG 배설률에 미치는 영향을 알아보고자 하였다. PET/CT 검사를 시행한 환자 중 신장의 원발성 종양 또는 전이 병변이 없는 환자를 대상으로 $^{18}F$-FDG와 함께 이뇨제를 주사한 그룹, 생리식염수를 주사한 그룹, $^{18}F$-FDG만을 주사 한 정상군 그룹으로 진행하였으며, 각 그룹의 관심영역을 설정하여 SUV를 측정하였다. 또한 정량적 분석을 위하여 $^{18}F$-FDG를 주사 후 이뇨제 투여 여부에 따른 SUV를 비교 평가하였다. SUV 측정에 따라 영상의 배후방사능이 감소된 영상을 얻을 수 있었으며 이뇨제 사용으로 배설된 소변의 양이 늘어났지만, 소변에 방사능량의 변화가 없는 상반된 결과가 나타났다. 따라서 이뇨제가 영상의 배후방사능을 줄일 수는 있지만 $^{18}F$-FDG 배설에는 영향을 미치지 못함을 확인 하였다.

흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구 (A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination)

  • 김영근;양숙;왕태욱;김은혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정 (Evaluation of Energy Dependency for Air Kerma Area Product by RQR Beam Quality and Indirect Calibration)

  • 김정수;김성환;김미정;이승열;이태희;성열훈
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.769-776
    • /
    • 2018
  • 국제전기기술위원회의 문서 IEC 60601-1의 3판 규격과 IEC 60601-2-45의 개별 규격에서는 진단용 X선 장치에서 X선 피폭 선량 정보를 표시하고 그 정확성을 명시할 것을 권고하고 있다. 하지만 임상에서 사용하는 부착형 공기커마 면적선량계는 교정에 어려움이 있다. 이에 본 연구에서는 임상에 적용 가능한 RQR 표준 선질을 이용하여 공기커마 면적선량계의 에너지 의존성과 정확도를 평가하였고 임상에서 간접 교정을 시행할 수 있도록 방법론을 마련하고자 하였다. RQR5의 표준 선질에서 시행한 시험에서 부착형 공기커마 면적선량계는 -7.5%의 오차를 나타냈고, RQR8의 표준 선질에서는 -10.3%의 오차를 나타냈으며 시험한 모든 RQR 선질에 대해 평균 절대오차는 $8.30%{\pm}2.85%$를 나타내 IEC 60580과 AAPM TG 190의 조건을 만족하였다. 본 연구에서 도출한 공기커마 면적선량계의 교정 방법은 임상에서 사용하는 공기커마 면적 선량계의 간접 교정법으로 사용할 수 있을 것으로 기대한다.

폴립 가중치 영상 생성을 통한 캡슐내시경 영상의 학습 성능 비교 연구 (A Study on the Comparison of Learning Performance in Capsule Endoscopy by Generating of PSR-Weigted Image)

  • 임창남;박예슬;이정원
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제8권6호
    • /
    • pp.251-256
    • /
    • 2019
  • 캡슐 내시경은 식도부터 항문까지 소화기관 전체를 한 번에 촬영할 수 있는 의료기기로, 한 번의 검사에서 평균 8~12시간의 길이와 5만장 이상의 프레임으로 구성된 영상을 생성한다. 그러나 생성된 영상에 대한 분석은 전문가에 의해 수작업으로 진행되고 있어서, 질병 영상 진단을 돕기 위한 영상 분석 자동화에 대한 수요가 증가하고 있다. 그 중에서도 본 연구에서는 위장관 내에서 발견될 수 있는 융기성 병변인 폴립 영상 자동 검출에 초점을 맞추었다. 본 연구에서는 멀티 스케일 분석을 통해 폴립 의심 영역을 추출하고, 이것을 원본 영상과 합성하여 폴립 학습을 강화시킬 수 있는 가중치 영상을 생성하는 기법을 제안한다. 수집한 452장의 데이터에 대해 머신 러닝 기법중 하나인 SVM과 RF로 실험한 결과, 원본 영상을 이용한 폴립 검출의 F1점수는 89.3%였지만, 생성된 가중치 영상을 통해 학습한 결과 F1점수가 93.1%로 향상된 것을 확인하였다.

유방 초음파 검사 시 S-detect 방법을 활용한 인자 분석 (Factor analysis using S-detect Method in Breast Ultrasound)

  • 천혜리;장현철;조평곤
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2019
  • 본 연구는 유방 초음파 검사 시 S-detect 성능에 관한 내용을 알아보고 이에 따라 조직 검사와 비교하여 불필요한 조직 검사를 줄일 수 있는 방안을 알아보고자 하였다. 2018년 8월에서 10월까지 유방초음파 검사를 시행한 환자 중 유방결절이 발견되어 조직 검사가 계획된 30명의 환자를 대상으로 후향적으로 분석하였다. S-detect 방법에서의 악성 감별과 Biopsy에서의 악성감별에 유의한 차이가 있는지 알아보기 위해 Mc Nemar test 분석을 실시하였다. S-detector 방법의 분석 결과 민감도는 90.9 %, 특이도 84.21 %, 정확도 86.66%, 양성예측도 76.92%, 음성예측도 94.11 %로 나타났다. S-detect 방법과 Biopsy 방법 간에 일치도 분석 결과 kappa 값이 0.724(p<0.05)로 높게 나타났으며, 두 방법 간에 좋은 일치도를 보였다. 유방초음파 검사 시 S-detect를 활용한 검사 방법에 있어서 유방 종괴에 악성과 양성 감별 진단에 있어서 진단적으로 가치가 있었으며, 유방조직 검사 실시 전 적절히 활용한다면 불필요한 조직 검사를 줄일 수 있는데 도음을 줄 것이다.

Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과 (The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304)

  • 김동국;송태하;정용훈;강관수;윤덕규;김민욱;우영재;서요한;김경아;노지형
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

말운동프로그램 향상을 위한 한국어 비단어 중재접근법의 확립 및 임상 적용 (Development and clinical application of Korean-version nonword intervention to improve speech motor programming)

  • 오다희;하지완
    • 말소리와 음성과학
    • /
    • 제13권2호
    • /
    • pp.77-90
    • /
    • 2021
  • 본 연구는 국외에서 개발된 비단어 중재접근법을 수정 및 보완하여 한국어 비단어 중재접근법을 확립하고, 아동기 말실행증 아동에게 직접 적용하여 그 효과를 확인하기 위해 실시되었다. 궁극적인 목적은 비단어를 이용한 중재가 아동기 말실행증의 말운동프로그래밍 능력을 개선시켜 비단어 산출 및 단어로의 일반화에 효과적인지 알아보기 위함에 있다. 중재는 아동기 말실행증의 진단 특성을 보이는 5세 6개월의 남아를 대상으로, ABA설계를 사용한 단일대상연구를 실시하였다. 중재에 사용된 비단어는 아동 맞춤형으로 제작하였으며, 한 회기당 60분씩 주 2회로, 총 12회기를 실시하였다. 그 결과 중재한 3음절 비단어의 모든 지표가 향상되었으며, 중재하지 않은 3음절, 4음절 비단어 및 단어로의 일반화를 확인하였다. 단, 단어로의 일반화 효과는 비단어로의 일반화 효과에 비해 미비하였다. 비단어 중재는 대상 아동의 말운동프로그래밍 능력을 개선시키는데 효과적이었다. 그 결과 운동프로그래밍 손상에 기인한 전환 오류가 크게 감소하였고, 중재하지 않은 비단어의 산출 능력이 큰 폭으로 증가하였다. 그러나 강력하게 습관화된 단어 오류를 완전히 개선시키는 데에는 한계가 있었으며, 이는 보다 집중적이고 반복적인 중재 일정을 제공했을 때 기대할 수 있는 결과일 것이다.