구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가 (Evaluation of the Beam Quality of Intraoral X-ray Equipments Using Intraoral Standard Films)

  • 이상섭;권혁락;심우현;오승현;이지연;전국진;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.183-188
    • /
    • 2000
  • Purpose: This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X -ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results: Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANP AS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. Conclusion: HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X -ray equipment should be managed in the planned and organized fashion.

  • PDF

고정밀도의 단상전파정류형 X선 장치의 제작 및 평가 (Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision)

  • 한동균;정재은;최준구;성렬훈;고신관
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.413-419
    • /
    • 2011
  • 1950년대 진단용 X선 장치의 국산화가 이루어졌으며, 1960년 초부터 진단용 X선 장치의 수요가 급격히 증가함에 따라 생산업체의 증가로 의료기기 시장의 많은 발전을 가져왔다. 진단용 X선 장치는 방사선에 대한 인체의 위험 요소인 피폭문제가 있기 때문에 보건복지가족부가 제조, 설치기준을 제정하고 있으며, 이를 기본으로 하여 KSA 4019, KS A 4021, KS A 4022 등에 의해 정밀한 제작이 이루어지고 있다. 진단용 X선 발생장치는 단상 전파 정류형과 삼상 전파 정류형이 대부분이나, 1980년대 이후 인버터식 X선 발생장치로 대부분 전환되기 시작하였다. 인버터식 X선 발생장치는 단상 전파정류형 X선 발생장치에 비해 1.5~1.8배의 높은 출력과 단시간 제어가 정확하지만, 가격이 비싸기 때문에 개인병원에서는 단상전파정류형 X선 장치를 선호하고 있어 단상 전파정류형 X선 장치의 성능개선이 요구된다. 이에 본 연구자들은 단상 전파정류형 X선 발생장치의 제어장치, 고전압 변압기, 필라멘트 가열변압기, 정류회로, 고압케이블 등 기기의 구성요소를 제작하고 진단용 X선 발생장치의 성능평가를 시험하였으며, 그 결과 국내 규정인 진단용 방사선 발생장치의 안전관리 규칙에 적합한 기준을 얻을 수 있었다.

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II) (A Study on Activities of Diagnostic X-ray Examination(II))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

진단용엑스선촬영장치의 간접 선량 계산법 개발 (Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment)

  • 김정수;김성환;전민철;주원하;정민규;김미정;이승열;이태희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

진단용엑스선장치 제조품질관리에 관한 국내.외 규격의 동향 (The Recent Trend of the National and International Standard of Manufacturing Quality Control for Diagnostic X-ray Equipment)

  • 최인석;김정민;정회원;민정환;이인수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.1-15
    • /
    • 2009
  • 진단용엑스선장치의 방사선방어 관한 내용을 중심으로 국내 외 규격을 살펴보고 신-구 IEC규격을 비교하여 본 결과는 다음과 같다. 가장 최근에 발표된 IEC 60601-1-3 ; 2008 2nd Edition에 담긴 철학은 크게 두 가지로서, 제조된 진단용 엑스선장치에 의하여 촬영 받게 될 환자를 위하여 어떤 종류의 방사선(선질 : Radiation Quality)을 얼마나 주었는지(선량 : Radiation Dose)를 확실히 해야 한다는 것이며 또 그 장치를 이용하는 작업자를 위하여 누설방사선(Leakage Radiation), 잉여방사선(Residual Radiation), 떠돌이 방사선(Stray Radiation)을 최소화해야 한다는 것이다. 진단용 엑스선장치에 관한 국내규격을 개정하거나 다시 제정할 경우 다음과 같은 내용과과정이 필요하다고 사료된다. 1. 가급적 최신 개념이 담긴 국제규격(IEC Publication)에 맞추되 우리나라의 실정에 맞는 규격을 채택하여야 할 것이다. 즉 IEC 60601-1-3 ; 2008을 근간으로 하고 미국의 CFR, 일본의 JIS도 참고한다면 지금 보다 한층 진보한 규격을 만들 수 있을 것이다. 2. 방사선안전부분을 중점적으로 고시하는 것이 간결하다. 즉 전기 기계적 안전에 관한 사항(IEC 60601-1)은 식품의약품안전청 고시 제 2006-7호 "의료기기의 전기 기계적 안전에 관한 공통기준규격"을 준용해야 한다. 3. 급격한 고시의 변화는 바람직하지 않다. 즉 최근에 개정된 IEC 60601-1-3 ; 2008을 도입하여 바로 적용하지 않고, 일단 현 규격을 일부 개정하여 사용하면서 적응기간을 가질 필요가 있다.

  • PDF

Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

  • Okazaki, Tohru;Hayashi, Hiroaki;Takegami, Kazuki;Okino, Hiroki;Kimoto, Natsumi;Maehata, Itsumi;Kobayashi, Ikuo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.229-236
    • /
    • 2016
  • Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.

진단용 X선 장치에서 방사선출력의 재현성 평가(IEC 60601-2-54 표준규격을 기반으로) (Evaluation of the Reproducibility of Radiation Output from Diagnostic X-ray Equipment(Standards Based on IEC 60601-2-54))

  • 한범희;정홍량;임청환;김종일;이상호;한상현;홍동희;김창규;유인규;모은희
    • 디지털융복합연구
    • /
    • 제12권2호
    • /
    • pp.555-561
    • /
    • 2014
  • 총 5대를 대상으로 한 진단용X선발생장치(DR)는 IEC 60601-2-54 표준규격에서 제시한 방사선출력의 재현성 시험에서 4대가 적합으로 나타났으며, 다만 1대의 X선 장치에서 C Group의 시험 설정인 진단용X선장치의 최고 관전압의 50%와 관전류 시간 곱(mAs)이 $1{\mu}Gy$에서 $5{\mu}Gy$ 사이의 인가출력량의 조합으로 측정한 항목에서 부적합으로 나타났다. 이에 따라 방사선량을 정량화하기 위한 표준으로 IEC 60601-2-54 표준규격에서 제시한 방사선출력의 재현성이 진단용 X선 영상장치 성능관리에 중요한 평가 요소임을 인식해야 한다.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

종합병원 일반 및 특수촬영유니트의 건축계획에 관한 연구 (A Study on the Architectural Planning of the X-ray Unit in General Hospital)

  • 윤우용;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2006
  • Planning for the space of the Media Medical Department requires the details about the efficiency of the equipment and the operation in professional sector. For that, as designing, it is necessary to keep communicating with the experts on the technology and the officials from the company producing the equipment. One of the common concerns is not only how to insure enough room for the future extension and the upgrade of the equipment, as concerning the scale of the hospital, but the plan to cover movie cameras. As technology has been developed, despite the fact that machinery tend to be small, it can be possible to require continuously about the concerns of the scale because the camera taking body-picture tend to be much bigger and more complicated than before. Currently used diagnostic media techniques are divided by the method and the feature of the equipment such as Diagnostic X-ray, Ultrasound, CT, MRI, Angiography. The general and special photographing units which are used more than the other diagnostic parts, must be planned not for experiencing any inconvenience and unnecessary risks for the patients and must accept technical requirements. Also, it must be designed not to be seen as a clinic zone, as concerning the psychological stability of the patients. However, study of the general and special photographing units among the domestic general hospitals is insufficient. Also, as there is shortage of the material considering the development of the equipment, when planning, it's involving a lot of difficulties. Thus, this study has got a purpose on giving the basic material which is essential for further study, as suggesting the planning guidelines and the alternative plans for the general and special photographing units in a general hospital.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.