• Title/Summary/Keyword: Diagnostic X-ray

Search Result 600, Processing Time 0.024 seconds

Absorbed Spectrum Comparison of Lead and Tungsten in Continuous X-ray Energy using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 연속 엑스선 에너지에서 납(Pb)과 텅스텐(W)의 흡수 스펙트럼 비교 연구)

  • Kim, Kyotae;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae;Cho, Changhoon;Heo, Yeji;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.483-487
    • /
    • 2012
  • In 1895, the discovered X-ray is used for not only in this field of medicine wide but also field. The detection of radiation after, people realized the risk of the radiation exposured recommended the principle about the protection of radiation by the part of the effort for lowering the radiation exposure. In this recommendation, all unnecessary radiation exposure have to be prevented by All doses include the protection of radiation, general idea of applicable two kinds of that it has to low maintain. Presently, in the General X-ray room of the clinical, the lead (Pb) was used for the shielding, However, because it had the problem of the lead poisoning which is fatal in the human body, the alternatives was showed. and Among them, the material that it is the tungsten was presented. in this research, the absorbed spectrum according to the thickness in the continuous X-ray energy of the tungsten which is not harmful to the human body through the Monte Carlo simulation, tried to compare with the absorbed spectrum of the lead (Pb). The tungsten confirmed that simulation presumption than result lead in the whole domain that absorbed probability was higher and it is considered that tungsten shows the absorbed efficiency higher than the lead in particularly, 70 keV ~ 90 keV and the tungsten is more useful to the X-ray energy cover of the high energy diagnostic area.

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

A Study on the Clinical Use of 7-zone-diagnostic System(1) Centering around VEGA-DFM 722 and ABR-2000- (7구역진단기의 임상응용에 대한 고찰(1) -VEGA-DFM 722 및 ABR-2000 중심으로-)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.231-239
    • /
    • 2006
  • Functional medicine is a system which utilizes certain investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. Functional disorders take place on an energetic plane. This plane is not capturable using our regular investigatory techniques, such as X -ray. ultrasound, computer tomography and laboratory analyses. The 7-zone-diagnostic system(VEGA-DFM 722 and ABR-2000, etc) is a diagnostic device Which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. The skin has many functions as an organ. It is the organism's interlace with the outsider world. Hence, the manner in which the skin reacts to external stimuli reflects the current state of the organism(as meridian systems). This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result chart. This result chart contain disorder flow wave forms and some valuable diagnostic hints (letters ; S, OM, RA, etc). In spite of this 7-zone-diagnostic system that is applied plentifully in the clinical application, there is not a statistics which is suitable. Therefor we must carry out many various research in the future.

  • PDF

Rare finding of Eustachian tube calcifications with cone-beam computed tomography

  • Syed, Ali Z.;Hawkins, Anna;Alluri, Leela Subashini;Jadallah, Buthainah;Shahid, Kiran;Landers, Michael;Assaf, Hussein M.
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.275-279
    • /
    • 2017
  • Soft tissue calcification is a pathological condition in which calcium and phosphate salts are deposited in the soft tissue organic matrix. This study presents an unusual calcification noted in the cartilaginous portion of the Eustachian tube. A 67-year-old woman presented for dental treatment, specifically for implant placement, and cone-beam computed tomography (CBCT) was performed. The CBCT scan was reviewed by a board-certified oral and maxillofacial radiologist and revealed incidental findings of 2 distinct calcifications in the cartilaginous portion of the Eustachian tube. To the authors' knowledge, no previous study has reported the diagnosis of Eustachian tube calcification using CBCT. This report describes an uncommon variant of Eustachian tube calcification, which has a significant didactic value because such cases are seldom illustrated either in textbooks or in the literature. This case once again underscores the importance of having CBCT scans evaluated by a board-certified oral and maxillofacial radiologist.

Clinical, virological, imaging and pathological findings in a SARS CoV-2 antibody positive cat

  • Ozer, Kursat;Yilmaz, Aysun;Carossino, Mariano;Ozturk, Gulay Yuzbasioglu;Bamac, Ozge Erdogan;Tali, Hasan E.;Mahzunlar, Egemen;Cizmecigil, Utku Y.;Aydin, Ozge;Tali, Hamid B.;Yilmaz, Semaha G.;Mutlu, Zihni;Kekec, Ayse Ilgin;Turan, Nuri;Gurel, Aydin;Balasuriya, Udeni;Iqbal, Munir;Richt, Juergen A.;Yilmaz, Huseyin
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.52.1-52.7
    • /
    • 2022
  • This paper reports a presumptive severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in a cat. A cat with respiratory disease living with three individuals with coronavirus disease 2019 showed bilateral ground-glass opacities in the lung on X-ray and computed tomography. The clinical swabs were negative for SARS-CoV-2 RNA, but the serum was positive for SARS-CoV-2 antibodies. Interstitial pneumonia and prominent type 2 pneumocyte hyperplasia were noted on histopathology. Respiratory tissues were negative for SARS-CoV-2 RNA or antigen, but the cat was positive for feline parvovirus DNA. In conclusion, the respiratory disease and associated pathology in this cat could have been due to exposure to SARS-CoV-2.

The Value of X-ray Compared with Magnetic Resonance Imaging in the Diagnosis of Traumatic Vertebral Fractures

  • Lee, Yang Woo;Jang, Jae Ho;Kim, Jin Joo;Lim, Yong Su;Hyun, Sung Youl;Yang, Hyuk Jun
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.158-165
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of X-rays in patients with acute traumatic vertebral fractures visiting the emergency department and to analyze the diagnostic value of X-rays for each spine level. Methods: We retrospectively analyzed basal characteristics by reviewing medical records of 363 patients with adult traumatic vertebral fractures, admitted to the emergency center from March 1, 2014 to February 28, 2017. We analyzed spine X-rays and magnetic resonance imaging (MRI) scans to determine distribution according to the vertebral level, and we evaluated the efficacy of X-rays by comparing discrepancies between X-rays and MRI scans. Results: For a total of 363 patients, the mean age was 56.65 (20-93) and 214 (59%) were males. On the basis of X-rays, 67 cases (15.1%) were of the cervical spine, 133 cases (30.0%) were of the thoracic spine, and 243 cases (54.9%) were of the lumbar spine. In particular, the thoracolumbar region (T11-L2) was the most common, with 260 cases (58.7%). In X-rays, fractures were the least in the upper thoracic region (T1-T3), whereas MRI scans revealed fairly uniform distribution across the thoracic spine. Sensitivity of X-rays was lowest in the upper thoracic spine and specificity was almost always greater than 98%, except for 94.7% in L1. Positive predictive value was lower in the mid-thoracic region (T4-T9) and negative predictive value was slightly lower in C6, T2, and T3 than at other sites. Diagnostic accuracy of X-rays by vertebral body, transverse process, and spinous process according to fractured vertebral structures was significantly different according to vertebral level. Conclusions: Diagnostic accuracy of X-rays was lower in the upper thoracic region than in other parts. Further studies are needed to identify better methods for diagnosis considering cost and neurological prognosis.

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • Ro, Duk-Woo;Choi, Hyung-Sik;Lim, Jae-Hoon;Kim, Won-Ki
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

Performance Test for Automatic Exposure Control by Zone System (Zone System을 이용한 자동노출장치의 성능 측정에 관한 실험)

  • Kang, Hee-Doo;Pyo, Chang-Gi;Cha, Jung-Hee;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 1998
  • AEC was designed to assist in the production of radiographs of equal density and to aid in the production f consistently high quality radiographs. Many improvements have been made in the AEC and these have helped to increase it's acceptance. Newer system (Falling load) control kVp and mA as well as exposure time. Authors have had experiments about the characteristics of AEC by Zone System. Zone System is the method to detection of photographic image qualify by control the photo print from Fred Archer and Ansel Adams. With the Zone System theory the experiments of density control, characteristics of phantom thickness and reproducibility of occupation rate of contrast media could make quality control of X-ray photography effectively in falling load system.

  • PDF

A Diagnostic Imaging Case of Cervical Spinal Subluxation for Chuna Mannual Therapy: Cervical Malposition with OPLL

  • Na, Hyun-Jong;Chang, Seok-Gon
    • The Journal of Korean Medicine
    • /
    • v.37 no.4
    • /
    • pp.45-48
    • /
    • 2016
  • Objectives: A diagnostic imaging in a fifty five year-old woman diagnosed orthopedically as ossification of posterior longitudinal ligament (OPLL) at C5 and C6 levels was reinterpreted for Chuna mannual therapy. The cervical spinal lesion in simple X-ray and CT scan images was discussed by spinal listing systems and disc block subluxation theory. The primary adjustive target was C4 disc block subluxation, which had been affected by kyphosis. Chuna manual therapy based on diagnostic images could be helpful for adjusting spinal subluxation, correcting its adaptation curvature, and preventing its latent pathology efficiently.