• Title/Summary/Keyword: Diagnostic Techniques

Search Result 648, Processing Time 0.033 seconds

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Evaluation of Effect of Decrease in Metallic Artifacts using the Synthetic MR Technique (Synthetic MR 기법을 이용한 금속 인공물 감소 효과 평가)

  • Soon-Yong, Kwon;Nam-Yong, Ahn;Jeong-Eun, Oh;Seong-Ho, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.835-842
    • /
    • 2022
  • This study is aimed to evaluate the effects of a synthetic MR technique in reducing metal artifacts. In the experiment, the in-plane and through-plane images were acquired by applying a synthetic MR technique and a high-speed spin echo technique to a phantom manufactured with screw for spinal surgery. The area of the metal artifact was compared. The metal artifacts were measured by dividing the signal-loss and the signal pile-up areas, and the area of the final artifact was calculated through the sum of the two. As a result, the metal artifacts were relatively reduced when the synthetic MR techniques were applied to both in-plane and through-plane. Comparing by sequence, the in-plane T1 images decreased by 23.45%, T2 images by 20.85%, PD images by 19.67%, and FLAIR images by 22.12%. Also, in the case of the through-plane, the T1 image decreased by 62.95%, the T2 image decreased by 73.93%, the PD image decreased by 74.68%, and the FLAIR image decreased by 66.43%. The cause of this result is that when the synthetic MR technique is applied, the distortion is due to the signal pile-up and does not occur and the size of the entire metal artifact is reduced. Therefore, synthetic MR technique can very effectively reduce metal artifacts, which can help to increase the diagnostic value of images.

EEG Feature Engineering for Machine Learning-Based CPAP Titration Optimization in Obstructive Sleep Apnea

  • Juhyeong Kang;Yeojin Kim;Jiseon Yang;Seungwon Chung;Sungeun Hwang;Uran Oh;Hyang Woon Lee
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.89-103
    • /
    • 2023
  • Obstructive sleep apnea (OSA) is one of the most prevalent sleep disorders that can lead to serious consequences, including hypertension and/or cardiovascular diseases, if not treated promptly. Continuous positive airway pressure (CPAP) is widely recognized as the most effective treatment for OSA, which needs the proper titration of airway pressure to achieve the most effective treatment results. However, the process of CPAP titration can be time-consuming and cumbersome. There is a growing importance in predicting personalized CPAP pressure before CPAP treatment. The primary objective of this study was to optimize the CPAP titration process for obstructive sleep apnea patients through EEG feature engineering with machine learning techniques. We aimed to identify and utilize the most critical EEG features to forecast key OSA predictive indicators, ultimately facilitating more precise and personalized CPAP treatment strategies. Here, we analyzed 126 OSA patients' PSG datasets before and after the CPAP treatment. We extracted 29 EEG features to predict the features that have high importance on the OSA prediction index which are AHI and SpO2 by applying the Shapley Additive exPlanation (SHAP) method. Through extracted EEG features, we confirmed the six EEG features that had high importance in predicting AHI and SpO2 using XGBoost, Support Vector Machine regression, and Random Forest Regression. By utilizing the predictive capabilities of EEG-derived features for AHI and SpO2, we can better understand and evaluate the condition of patients undergoing CPAP treatment. The ability to predict these key indicators accurately provides more immediate insight into the patient's sleep quality and potential disturbances. This not only ensures the efficiency of the diagnostic process but also provides more tailored and effective treatment approach. Consequently, the integration of EEG analysis into the sleep study protocol has the potential to revolutionize sleep diagnostics, offering a time-saving, and ultimately more effective evaluation for patients with sleep-related disorders.

Development of smart car intelligent wheel hub bearing embedded system using predictive diagnosis algorithm

  • Sam-Taek Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.10
    • /
    • pp.1-8
    • /
    • 2023
  • If there is a defect in the wheel bearing, which is a major part of the car, it can cause problems such as traffic accidents. In order to solve this problem, big data is collected and monitoring is conducted to provide early information on the presence or absence of wheel bearing failure and type of failure through predictive diagnosis and management technology. System development is needed. In this paper, to implement such an intelligent wheel hub bearing maintenance system, we develop an embedded system equipped with sensors for monitoring reliability and soundness and algorithms for predictive diagnosis. The algorithm used acquires vibration signals from acceleration sensors installed in wheel bearings and can predict and diagnose failures through big data technology through signal processing techniques, fault frequency analysis, and health characteristic parameter definition. The implemented algorithm applies a stable signal extraction algorithm that can minimize vibration frequency components and maximize vibration components occurring in wheel bearings. In noise removal using a filter, an artificial intelligence-based soundness extraction algorithm is applied, and FFT is applied. The fault frequency was analyzed and the fault was diagnosed by extracting fault characteristic factors. The performance target of this system was over 12,800 ODR, and the target was met through test results.

Experimental study on structural integrity assessment of utility tunnels using coupled pulse-impact echo method (결합된 초음파-충격 반향 기법 기반의 일반 지하구 구조체의 건전도 평가에 관한 실험적 연구)

  • Jin Kim;Jeong-Uk Bang;Seungbo Shim;Gye-Chun Cho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.479-493
    • /
    • 2023
  • The need for safety management has arisen due to the increasing number of years of operated underground structures, such as tunnels and utility tunnels, and accidents caused by those aging infrastructures. However, in the case of privately managed underground utility ducts, there is a lack of detailed guidelines for facility safety and maintenance, resulting in inadequate safety management. Furthermore, the absence of basic design information and the limited space for safety assessments make applying currently used non-destructive testing methods challenging. Therefore, this study suggests non-destructive inspection methods using ultrasonic and impact-echo techniques to assess the quality of underground structures. Thickness, presence of rebars, depth of rebars, and the presence and depth of internal defects are assessed to provide fundamental data for the safety assessment of box-type general underground structures. To validate the proposed methodology, different conditions of concrete specimens are designed and cured to simulate actual field conditions. Applying ultrasonic and impact signals and collecting data through multi-channel accelerometers determine the thickness of the simulated specimens, the depth of embedded rebar, and the extent of defects. The predicted results are well agreed upon compared with actual measurements. The proposed methodology is expected to contribute to developing safety diagnostic methods applicable to general underground structures in practical field conditions.

Exosomes isolation from bovine serum: qualitative and quantitative comparison between ultracentrifugation, combination ultracentrifugation and size exclusion chromatography, and exoEasy methods

  • Eun-Yeong Bok;Sang Young Seo;Han Gyu Lee;Sudu Hakuruge Madusha Pramud Wimalasena;Eunju Kim;Ara Cho;Young-Hun Jung;Tai-Young Hur;Kyoung-Min So;Sung-Lim Lee;Yoon Jung Do
    • Journal of Animal Science and Technology
    • /
    • v.66 no.5
    • /
    • pp.1021-1033
    • /
    • 2024
  • Exosomes have been extensively studied as disease biomarker in humans, given their role in transporting bioactive molecules. However, despite the great potential of exosomes as noninvasive diagnostic markers and therapeutic nanocarriers for bovine diseases, few studies have been conducted on bovine exosome. Thus, this study aimed to quantitatively and qualitatively compare three isolation methods to identify a suitable method for bovine serum. Exosomes were isolated using ultracentrifugation alone (UC), a combination of ultracentrifugation and size exclusion chromatography (US), or membrane affinity-based exoEasy kit (EE). Isolated particles were evaluated using a range of complementary techniques. Transmission electron microscopy showed that all three isolation methods resulted in particles with a cup-shaped morphology. The particle concentration measured by nanoparticle trafficking analyzer of US was lower compared to those of UC and EE method. As a result of immunoblotting, exosome markers including TSG101, CD81, and HSP70 were detected in US particles, while in UC and EE, only TSG101 expression was confirmed. Particles isolated from UC and EE showed a contamination with the blood protein albumin, whereas particles from US did not show albumin contamination. In addition, to evaluate the possibility of using exosomes as biomarkers, the profiles of the small RNA in the exosomes were compared using the bioanalyzer 2100. As a result, in the EE method, the band of small RNA (25-200 nt) was most prominent, and in the US methods, a distinct band was observed in the small RNA range. Collectively, the purity of exosomes without non-exosomal contamination was highest in the US method. However, for the detection of small RNA, the EE method was found to be the most suitable. Therefore, the results suggest that the optimal isolation method varies depending on the specific purpose of exosome isolation.

Patterns of care for patients with nasopharyngeal carcinoma (KROG 11-06) in South Korea

  • Sung, Soo Yoon;Kang, Min Kyu;Kay, Chul Seung;Keum, Ki Chang;Kim, Sung Hwan;Kim, Yeon-Sil;Kim, Won Taek;Kim, Ji-Yoon;Kim, Jin-Hee;Moon, Sung Ho;Ahn, Yong Chan;Oh, Young Taek;Wu, Hong-Gyun;Lee, Chang-Geol;Chung, Woong-Ki;Cho, Kwan Ho;Cho, Moon-June;Choi, Jin Hwa
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.188-197
    • /
    • 2015
  • Purpose: To investigate the patterns of care for patients with nasopharyngeal carcinoma (NPC) in South Korea. Materials and Methods: A multi-institutional retrospective study was performed (Korean Radiation Oncology Group [KROG] 11-06) on a total of 1,445 patients from 15 institutions. Results: Of the 1,445 patients, more than half were stages III (39.9%) and IV (35.8%). In addition to patterns of care, we also investigated trends over time with the periods 1988-1993, 1994-2002, and 2003-2011. The frequencies of magnetic resonance imaging and positron emission tomography-computed tomography were markedly increased in the third period compared to previous 2 periods. Concurrent chemoradiation (CCRT) was performed on 894 patients (61.9%), neoadjuvant chemotherapy on 468 patients (32.4%), and adjuvant chemotherapy on 366 patients (25.3%). Of stage II-IV patients, CCRT performed on 78.8% in 2003-2011 compared to 15.0% in 1988-1993. For patients treated with CCRT, cisplatin was the most commonly used agent in 81.3% of patients. Over the periods of time, commonly used radiotherapy (RT) techniques were changed from 2-dimensional RT (1988-1993, 92.5%) to 3-dimensional RT (2003-2011, 35.5%) or intensity-modulated RT (IMRT; 2003-2011, 56.5%). Median RT doses given to primary tumors, high-risk lymphatics, and low-risk lymphatics were 70.0 Gy, 58.1 Gy, and 48.0 Gy, respectively. Adoption of IMRT increased the dose per fraction and escalated total radiation dose. Conclusion: Assessment of the patterns of care for NPC patients in South Korea demonstrated that management for NPC including diagnostic imaging, treatment regimen, RT techniques and dose schedule, advanced in accordance with the international guidelines.

Regeneration of Low Heat - Treated Sciatic Nerve of Rabbit (저온 열처리한 가토 좌골 신경의 재생)

  • Kim, Jae-Do;Kim, Sang-Jin;Jung, Cheoul-Yun;Hong, Young-Gi;Kim, Ghi-Chan
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.2
    • /
    • pp.80-88
    • /
    • 1997
  • Malignant tumors of extremeties involving major neurovascular structures have been treated by amputation. However recent development of diagnostic tools(CT, MRI etc.), surgical techniques, anticancer chemotherapeutic agents, and radiation techniques allow surgeons to treat malignant tumors in the limb without amputation. It has been reported that a local application of low-heat to the tissue with tumor can kill tumor cells. It is, however, not known if the attendant neural and vascular injuries may be recovered. The present study was, therefore, undertakn to address this question in rabbit sciatic nerves. A low-heat injury to the sciatic nerve was induced by perfusing the nerve with $60^{\circ}C$ saline for 30 minutes and the courses of functional and morphological recovery of the nerve were evaluated for 16 weeks. The results are summerized as follows : 1. In the electromyographic nerve conduction test the average amplitude was markedly attenuated at 4 and 8 weeks after the low-heat treatment, but it progressively increased to the level 89.5% of the control at 16 week post-treatment. The average latency in the control group was 0.62 msec. The latency in the experimental group was much longer than this at 4 and 8 week post-treatment, but it progressively reverted to the control level, showing 0.622 msec at 16 weeks. 2. In the needle EMG, many fibrillation potentials and positive sharp waves were appeared until 8 weeks post-treatment. After 16 weeks, however, no fibrillation potential was observed. 3. In the early phase of post-treatment period, the myelinated nerve fibers contained many vacuoles and the number of myelinated nerve fibers appeared to be considerably reduced. However, as time goes myelinated nerve fibers were regenerated, such that after 16 weeks the histologic appearance of the nerve was similar to that of the control group.

  • PDF

Establishment and Application of Molecular Genetic Techniques for Preimplantation Genetic Diagnosis of Osteogenesis Imperfecta (골형성부전증의 착상전 유전진단을 위한 분자유전학적 방법의 조건 확립과 적용)

  • Kim, Min-Jee;Lee, Hyoung-Song;Choi, Hye-Won;Lim, Chun-Kyu;Cho, Jae-Won;Kim, Jin-Young;Song, In-Ok;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.2
    • /
    • pp.99-110
    • /
    • 2008
  • Objectives: Preimplantation genetic diagnosis (PGD) has become an assisted reproductive technique for couples carrying genetic conditions that may affect their offspring. Osteogenesis imperfecta (OI) is an autosomal dominant disorder of connective tissue characterized by bone fragility and low bone mass. At least 95% of cases are caused by dominant mutations in the COL1A1 or COL1A2. In this study, we report on our experience clinical outcomes with 5 PGD cycles for OI in two couples. Methods: Before clinical PGD, we assessed the amplification rate and allele drop-out (ADO) rate of alkaline lysis and nested PCR protocol using heterozygous patient's single lymphocytes in the pre-clinical diagnostic tests for OI. We performed 5 cycles of PGD for OI by nested PCR for the causative mutation loci, COL1A1 c.2452G>A and c.3226G>A, in case 1 and case 2, respectively. The PCR products were analyzed by agarose gel electrophoresis, restriction fragment length polymorphism (RFLP) analysis with HaeIII restriction enzyme in the case 1 and direct DNA sequencing. Results: We confirmed the causative mutation loci, COL1A1 c.2452G>A in case 1 and c.3226G>A in case 2. In the pre-clinical tests, the amplification rate was 94.2% and ADO rate was 22.5% in case 1, while 98.1% and 1.9% in case 2, respectively. In case 1, a total of 34 embryos were analyzed and 31 embryos (91.2%) were successfully diagnosed in 3 PGD cycles. Eight out of 19 embryos diagnosed as unaffected embryos were transferred in all 3 cycles, and in the third cycle, pregnancy was achieved and a healthy baby was delivered without any complications in July, 2005. In case 2, all 19 embryos (100.0%) were successfully diagnosed and 4 out of 11 unaffected embryos were transferred in 2 cycles. Pregnancy was achieved in the second cycle and the healthy baby was delivered in March, 2008. The causative locus was confirmed as a normal by amniocentesis and postnatal diagnosis. Conclusions: To our knowledge, these two cases are the first successful PGD for OI in Korea. Our experience provides a further demonstration that PGD is a reliable and effective clinical techniques and a useful option for many couples with a high risk of transmitting a genetic disease.

Clinical Characteristics of Pulmonary Cryptococcosis (국내 폐효모균증의 임상적 특징)

  • Moon, Doo-Seop;Yoo, Jeong-Soo;Kim, Chung-Mi;Kim, Yeon-Soo;Kim, Seung-Min;Oh, Kwang-Taek;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Hahm, Shee-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1083-1093
    • /
    • 1997
  • Background : So far, there have been numerous reports on organ damage due to cryptococcosis, however, cases of lung localization have been infrequently reported. Recently pulmonary cryptococcosis has been reported more frequently than before due to enhanced diagnostic techniques and increased underlying diseases. Method : The author, therefore, analyzed the clinical manifestations of 5 cryptococcosis cases that we experienced at Hanyang University Hospital from 1985 to 1996 and 9 cases reported in Korea from 1984 and 1996 retrospectively. The following results were obtained. Results : Cryptococcosis occurred frequently over sixth decade and the male to female ratio was 3.6 : 1. Underlying diseases included acute rejection after kidney transplantation, rheumatoid arthritis, autoimmune hepatitis, diabetes mellitus and state of bilateral adrenalectomy. Remaining 8 cases had no evidence of an underlying disease. Because the symptoms were subacute & nonspecific, and not improved by conventional antibiotics, 6 patients of 14 pulmonary cryptococcosis patients were treated as pulmonary tuberculosis before correct diagnosis was made. There were three asymptomatic cases. According to the results of CXR, solitary alveolar consolidation was the most common finding(8 cases) followed by diffuse infiltration(5 cases). It also showed pleural effusion, hilar lymphadenopathy and cavity formation that was rarely reported in world literature. The diagnasis was made through fine needle aspiration biopsy in 10 cases, open thoracotomy in 2 cases, transbronchial lung biopsy in 1 case. and thoracentesis with pleural biopsy in 1 case. Only one case showed positive result in sputum stain and culture, serum latex agglutination test for cryptococcus neoformans. Treatment modalities were various such as fluconazole, amphotericin B, flucytosine, ketoconazole, surgery and it's combination. After 1990 year, there was a trend that fluconazole or ketoconazole are more used than other therapeutic modalities. Conclusion : Because the symptoms are subacute & nonspecific and not improved by conventional antibiotics, pulmonary cryptococcosis is likely to misdiagnosis as pulmonary tuberculosis in Korea. Because the diagnosic yield of sputum stain, culture and serologic test for pulmonary cryptococcosis is low, histologic diagnosis is need in most pulmonary cryptococcosis.

  • PDF