• Title/Summary/Keyword: Diagnostic Possibility

Search Result 285, Processing Time 0.031 seconds

An Exploratory Study on the Possibility of Quantitative Measurement during Abdominal Examinations - A Preliminary Study on the Development of a Diagnostic Device for Abdominal Examinations (한의복진법의 정량화를 위한 탐색적 임상연구 - 한의 복진기기 개발을 위한 예비 연구 -)

  • Lee, Jae-hong;Kim, Sang-jin;Ko, Seok-jae;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.6
    • /
    • pp.940-948
    • /
    • 2016
  • Objectives: This exploratory trial evaluated the possibility of quantitatively measuring several aspects during the "abdominal examination" of traditional Korean medicine. The main results of this study will be used to develop a new diagnostic device for abdominal examinations. Methods: Fifteen healthy volunteers were recruited for this study. Three certified Korean medical doctors assessed the existence of pressure pain, the elasticity of the abdominal muscle, and the tonus at CV12 as gold standards. Then, 2 well-trained investigators measured the pressure pain threshold (PPT), the indentation depth of a bar, and repelling force by pressing CV12. Each investigator measured the above 3 variables 2 times at 1 min intervals using a modified digital algometer. Reliability and validity tests of the 3 variables were performed. Results: There were statistically significant coefficients of intraclass correlation on the 3 variables both between and within the investigators (P<0.001). Also, PPT and repelling force showed statistically significant high sensitivity and specificity in a ROC curve. However, the indentation depth of the bar presented relatively low sensitivity. Conclusions: This new diagnostic method using a modified digital algometer could be a useful tool for quantitative measurement in "abdominal examinations". However, future rigorous clinical studies with a large population will be needed for the verification of its usefulness.

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

The Study on the Upgrade of QSCC II (II) - The study on the re-validity of QSCC II- (사상체질분류검사지(QSCC II)의 Upgrade 연구 (II) - 사상체질분류검사지(QSCC II)의 재타당화 연구 -)

  • Kwak, Chang-Kyu;Lee, Eui-Ju;Ko, Byung-Hee;Song, Il-Byung;Lee, Sang-Gyu
    • Journal of Sasang Constitutional Medicine
    • /
    • v.15 no.1
    • /
    • pp.39-49
    • /
    • 2003
  • 1. The purpose of study The problem lies in the Sasang-constitutional-medicine is a subjectiveness of diagnosis that can be varied by every donor. Questionnare for the Sasang Constitution Classification II(QSCCII) was invented to solve this problem. This study was conducted for two purpose. The one is re-value the QSCCII. The other is to make a basis to upgrade QSCCII. 2. The method of study QSCCII was administered to 537 patients at Kyung Hee Oriental Medicine Hospital. Data was collected during 19 months from september 2000 to march 2002. For the purpose of this study, the collected data was analyzed by crosstabs, variation analysis and discrimination analysis. The analyzing program was SPSS 8.0 for Windows. And using this program I made the judgmental equation to re-value the QSCCII. 3. The result of study 1) not applied intensifying value The diagnostic discrimination abilities of the QSCCII is 61.5% about Taeyangin, 57.7% about Soyangin, 67.2% about Taeumin, 68.8% about Soemin. And its average is 65.0%. 2) applied intensifying value The diagnostic discrimination abilities of the QSCCII is 76.9% about Taeyangin, 59.9% about Soyangin, 68.9% about Taeumin, 71.2% about Soemin. And its average is 67.3%. 3) I propose a new diagnostic possibility with a different discriminant analysis and increase 42.3% of diagnostic discrimination ability considering 25% of accident diagnostic discrimination ability. 4) Development and complement of Taeyangin and Soyangin questions is needed to increase the accuracy of diagnosis.

  • PDF

Acupuncture: How Might the Mechanisms of Treatment Have Contributed to the Diagnosis of "Patterns" and Pattern-based Treatments - Speculations on the Evolution of Acupuncture as a Therapy. Implications for Researchers

  • Birch, Stephen
    • Journal of Acupuncture Research
    • /
    • v.35 no.2
    • /
    • pp.47-51
    • /
    • 2018
  • Acupuncture is a complex intervention that manifests varied theories, treatment methods, diagnostic methods and diagnostic patterns. Traditionally based systems of acupuncture (TBSAs) often have their own diagnostic approaches and patterns. Despite the wide variety that can be found amongst TBSAs, is it possible that they share a common background in clinical observation and practice? Research has shown that multiple physiological pathways and mechanisms can be triggered by different acupuncture techniques and methods. It is highly likely that clinicians will have observed some of the effects of these responses and used those observations as feedback to help construct the patterns of diagnosis and their associated treatments. This review briefly examines this possibility. Pattern identification will have developed out of a complex interaction of factors that include; theories current at the time of their development, historical theories, personal choices and beliefs, training, practice methods, clinical observations and the natural feedback that comes from observing how things change once the treatment is applied. Researchers investigating TBSAs and pattern identification need to be more explicit about the systems they have investigated in order to understand the biological basis of pattern identification and their treatments.

Remote Measurement of ECU Sensor Signal based on the Embedded Linux and Web (임베디드 리눅스와 웹 기반의 ECU 센서신호 원격계측)

  • 이현호;최광훈;권대규;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1042-1045
    • /
    • 2003
  • In this paper, we present a new method for the monitoring of Electric Control Unit's(ECU) self-diagnostic and the sensor signals of vehicle through Web. In order to measure the ECU's self-diagnostic and sensor signals, the interfaced circuit is designed to communicate ECU and terminal according to the ISO, SAE regulation of communication protocol standard. Microprocessor 80C196KC is used for communicating ECU's self-diagnostic signals and the results are sent to the Embedded Linux System(ELS) through RF module. ELS is developed by SA1110, RF module, Embedded Linux. All commands related in ECU communication are executed through Web. The CGI program composed in web server is executed by user and will return sensor signals from ECU Software on Embedded Linux system is developed to monitor the ECU's sensor signals using the arm compiler tool chain in which RS232 port is programmed by half duplex method. The possibility for remote measurement of ECU sensor signal through Web is verified through the developed systems and algorithms.

  • PDF

Applying KS-15 (Korea Sasang Constitutional Diagnostic Questionnaire) to the Japanese : a Pilot Study (단축형 사상체질 진단설문지(KS-15)의 일본인 적용 가능성 확인을 위한 예비연구)

  • Park, Ki Hyun;Baek, Young Hwa;Lee, Si Woo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.70-74
    • /
    • 2018
  • The purpose of this study was to evaluate the possibility of applying Korea Sasang Constitutional Diagnostic Questionnaire(KS-15) for the Japanese. We analyzed the results of 50 Japanese participants who visited the local university hospital from October 2010 to July 2011 and their Sasang constitutions were diagnosed by a Sasang Constitutional specialist. Two items(14.3%) of total 14 items, except for BMI showed 0.4 or below in Kappa, 8 items(57.1%) were ranged from 0.4 to 0.6 and 4 items(28.6%) marked 0.6 or over. The concordance rate between the results of KS-15 and those of expert was 60% in total Japanese participants.(61.9% in Taeeumin, 60% in Soeumin, and 57.9% in Soyangin). The KS-15 could be suitable for supporting experts to diagnose the Sasang constitution of the Japanese. In order to increase usefulness, when subsequently applying KS-15 to foreign site, KS-15 should be properly adjusted in sociocultural characteristic.

Measurement of Apnea Using a Polyvinylidene Fluoride Sensor Inserted in the Pillow (베게에 삽입된 PVDF센서를 이용한 무호흡증 측정)

  • Keum, dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.407-413
    • /
    • 2018
  • Most sleep apnea patients exhibit severe snoring, and long-lasting sleep apnea may cause insomnia, hypertension, cardiovascular diseases, stroke, and other diseases. Although polysomnography is the typical sleep diagnostic method to accurately diagnose sleep apnea by measuring a variety of bio-signals that occur during sleep, it is inconvenient as the patient has to sleep with attached electrodes at the hospital for the diagnosis. In this study, a diagnostic pillow is designed to measure respiration, heart rate, and snoring during sleep, using only one polyvinylidene fluoride (PVDF) sensor. A PVDF sensor with piezoelectric properties was inserted into a specially made instrument to extract accurate signals regardless of the posture during sleep. Wavelet analysis was used to identify the extractability and frequency domain signals of respiration, heart rate, and snoring from the signals generated by the PVDF sensor. In particular, to separate the respiratory signal in the 0.2~0.5 Hz frequency region, wavelet analysis was performed after removing 1~2 Hz frequency components. In addition, signals for respiration, heart rate, and snoring were separated from the PVDF sensor signal through a Butterworth filter and median filter based on the information obtained from the wavelet analysis. Moreover, the possibility of measuring sleep apnea from these separated signals was confirmed. To verify the usefulness of this study, data obtained during sleeping was used.

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Auditory Hallucination in Schizophrenia treated by Daeseunggi-tang : A Case Report (대승기탕(大承氣湯)으로 호전된 조현병 환청에 대한 증례 1례)

  • Rho, Yeong-Beom;Jo, Gang-Mun
    • 대한상한금궤의학회지
    • /
    • v.6 no.1
    • /
    • pp.79-88
    • /
    • 2014
  • Objective : We report efficacy of Daeseunggi-tang on auditory hallucination in schizophrenia. From this, we can expect therapeutic possibility of herbal medicine chosen by 'A disease pattern identification diagnostic system based on Shanghanlun provisions' in schizophrenia. Methods : Daeseunggi-tang written in YangMyeong-JiWiByeong is applied to 31-year-old patient who diagnosed as schizophrenia and hospitalized for 3months taking antipsychotics. The patient was treated for a year. Results : Scores in Auditory Hallucination appended to PANSS and K-BDI were highly decreased. The patient takes no antipsychotics anymore for now. Conclusions : Auditory hallucination in Schizophrenia which needs antipsychotics can be managed by herbal medicine chosen by 'A disease pattern identification diagnostic system based on Shanghanlun provisions'.

The Role of Capsule Endoscopy in the Diagnosis of Crohn's Disease

  • Rhee, Kang-Won
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.15 no.1
    • /
    • pp.8-12
    • /
    • 2012
  • The examination of small bowel in Crohn's disease (CD) is very important. Capsule endoscopy (CE) has been recognized as a good tool for evaluation of small bowel. The capsule placement is achieved endoscopically for Children not to swallow capsule. CE is superior to any other modalities for examination of small-bowel. The large portion of pediatric patients with known CD were found with CE to have more extensive and newly diagnostic small-bowel disease. All of them had therapeutic changes. The most side effect of CE is capsule retention. The capsule retention rate in pediatric CD is about 7.3%. The patency capsule helps to predict the possibility of capsule retention. For the improving of the diagnostic accuracy, the experience of more than 20 readings of CE is needed.