• Title/Summary/Keyword: Diagnostic Matrix

Search Result 131, Processing Time 0.026 seconds

Damage detection of mono-coupled multistory buildings: Numerical and experimental investigations

  • Xu, Y.L.;Zhu, Hongping;Chen, J.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.709-729
    • /
    • 2004
  • This paper presents numerical and experimental investigations on damage detection of mono-coupled multistory buildings using natural frequency as only diagnostic parameter. Frequency equation of a mono-coupled multistory building is first derived using the transfer matrix method. Closed-form sensitivity equation is established to relate the relative change in the stiffness of each story to the relative changes in the natural frequencies of the building. Damage detection is then performed using the sensitivity equation with its special features and minimizing the norm of an objective function with an inequality constraint. Numerical and experimental investigations are finally conducted on a mono-coupled 3-story building model as an application of the proposed algorithm, in which the influence of modeling error on the degree of accuracy of damage detection is discussed. A mono-coupled 10-story building is further used to examine the capability of the proposed algorithm against measurement noise and incomplete measured natural frequencies. The results obtained demonstrate that changes in story stiffness can be satisfactorily detected, located, and quantified if all sensitive natural frequencies to damaged stories are available. The proposed damage detection algorithm is not sensitive to measurement noise and modeling error.

Optimal Design of a-Si TFT Array for Minimization of Data-line Capacitance and Its Implementation (데이터 배선 용량 최소화를 위한 비정질 실리콘 박막 트렌지스터 배열의 최적화 설계와 구현)

  • Kim, C.W.;Yoon, J.K.;Kim, S.Y.;Kim, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.392-399
    • /
    • 2008
  • Thin-film transistor (TFT) arrays for an x-ray detector require quite different design concept from that of the conventional active-matrix liquid crystal devices (AM-LCDs). In this paper anew design of TFT array which uses only SiNx for passivation layer is described to meet the detector performance and the product availability simultaneously. For the purpose of optimizing the design parameters of the TFT array, a Spice simulation was performed. As a result, some parameters, such as the TFT width, the data line capacitance, and the storage capacitance, were able to be fixed. The other parameters were decided within a permissible range of the TFT process especially the photolithography process and the wet etch process. Then we adapted the TFT array which had been produced by the proposed design to our prototype model (FDXD-1417 and evaluated it clinically by comparing with a commercial model (EPEX, Hologic, Beford, USA). The results say that our prototype model is slightly better than EPEX system in chest PA images. So we can prove the technical usefulness and the commercial values of the proposed TFT design.

Automated epileptic seizure waveform detection method based on the feature of the mean slope of wavelet coefficient counts using a hidden Markov model and EEG signals

  • Lee, Miran;Ryu, Jaehwan;Kim, Deok-Hwan
    • ETRI Journal
    • /
    • v.42 no.2
    • /
    • pp.217-229
    • /
    • 2020
  • Long-term electroencephalography (EEG) monitoring is time-consuming, and requires experts to interpret EEG signals to detect seizures in patients. In this paper, we propose a novel automated method called adaptive slope of wavelet coefficient counts over various thresholds (ASCOT) to classify patient episodes as seizure waveforms. ASCOT involves extracting the feature matrix by calculating the mean slope of wavelet coefficient counts over various thresholds in each frequency subband. We validated our method using our own database and a public database to avoid overtuning. The experimental results show that the proposed method achieved a reliable and promising accuracy in both our own database (98.93%) and the public database (99.78%). Finally, we evaluated the performance of the method considering various window sizes. In conclusion, the proposed method achieved a reliable seizure detection performance with a short-term window size. Therefore, our method can be utilized to interpret long-term EEG results and detect momentary seizure waveforms in diagnostic systems.

BENIGN AND MALIGNANT MYOEPITHELIOMAS IN SALIVARY GLAND: CASES REPORT AND IMMUNOHISTOCHEMICAL STUDY (양성 및 악성 타액선 근상피종: 증례보고 및 면역조직화학적 연구)

  • Byun, June-Ho;Lee, Jong-Sil;Kim, Jong-Ryoul;Park, Bong-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.71-76
    • /
    • 2009
  • Benign myoepithelioma (BME) and malignant myoepithelioma (MME) of the salivary gland are very rare and its biologic behavior has not been clarified fully. Although, cases reports for BME and MME were increased in recent, their diagnostic criteria were not completely established. We describe herein a case of BME of the parotid gland and a case of MME of the palatal minor gland, respectively. Histologically, multinodular growth pattern, infiltration to adjacent tissues, and hyalinized and myxoid matrix were observed in MME, that were different histologic features compared with BME. Strong immunoreactivities for the S-100 protein and vimentin were detected in the tumor cells of BME and MME. In specimen of MME, moderately expressed p53 and strongly expressed p63 were detected. However, in specimen of BME, p53 was negatively and p63 was weakly expressed, respectively. In conclusion, the expression patterns of p53 and p63 as well as histologic aggressiveness might be used to diagnose the MME.

ANTERIOR ESTHETIC RESIN RESTORATION OF INTELLECTUALLY DISABLED CHILD WITH OLIGODONTIA : A CASE REPORT (부분 무치증을 동반한 지적장애 환자의 전치부 심미수복 : 증례보고)

  • Bae, Youngeun;Kim, Jiyeon;Jeong, Taesung
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.12 no.2
    • /
    • pp.66-71
    • /
    • 2016
  • Intellectual disability is accompanied by a high incidence of congenitally absent teeth and supernumerary teeth, and is observed more frequently than are disorders of location and order during delayed eruption, when accompanied by other symptoms. Furthermore, it is associated with a higher occurrence of dental anomalies such as conical teeth, microdontia, and amelogenesis imperfecta. As it is difficult to obtain adequate cooperation from patients with intellectual disabilities, physical restraint and conscious sedation using medication and general anesthesia can be considered. Reshaping of conical teeth with resin composite may be helpful to rehabilitate patients with oligodontia and a conical tooth shape. Diagnostic wax-up and a silicone matrix formed the basis for the successful reconstruction of the anterior teeth. This case describes the treatment of a patient with intellectual disability who had oligodontia and conical-shaped incisors. Under general anesthesia, the patient was treated using direct composite resin restoration.

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

Support vector ensemble for incipient fault diagnosis in nuclear plant components

  • Ayodeji, Abiodun;Liu, Yong-kuo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1306-1313
    • /
    • 2018
  • The randomness and incipient nature of certain faults in reactor systems warrant a robust and dynamic detection mechanism. Existing models and methods for fault diagnosis using different mathematical/statistical inferences lack incipient and novel faults detection capability. To this end, we propose a fault diagnosis method that utilizes the flexibility of data-driven Support Vector Machine (SVM) for component-level fault diagnosis. The technique integrates separately-built, separately-trained, specialized SVM modules capable of component-level fault diagnosis into a coherent intelligent system, with each SVM module monitoring sub-units of the reactor coolant system. To evaluate the model, marginal faults selected from the failure mode and effect analysis (FMEA) are simulated in the steam generator and pressure boundary of the Chinese CNP300 PWR (Qinshan I NPP) reactor coolant system, using a best-estimate thermal-hydraulic code, RELAP5/SCDAP Mod4.0. Multiclass SVM model is trained with component level parameters that represent the steady state and selected faults in the components. For optimization purposes, we considered and compared the performances of different multiclass models in MATLAB, using different coding matrices, as well as different kernel functions on the representative data derived from the simulation of Qinshan I NPP. An optimum predictive model - the Error Correcting Output Code (ECOC) with TenaryComplete coding matrix - was obtained from experiments, and utilized to diagnose the incipient faults. Some of the important diagnostic results and heuristic model evaluation methods are presented in this paper.

Genetic Distances Within-Population and Between-Population of Tonguesole, Cynoglossus spp. Identified by PCR Technique

  • Yoon, Jong-Man
    • Development and Reproduction
    • /
    • v.23 no.3
    • /
    • pp.297-304
    • /
    • 2019
  • The higher fragment sizes (>2,100 bp) are not observed in the two C. spp. populations. The six oligonucleotides primers OPA-11, OPB-09, OPB-14, OPB-20, OPC-14, and OPC-18 were used to generate the unique shared loci to each tonguesole population and shared loci by the two tonguesole populations. The hierarchical polar dendrogram indicates two main clusters: Gunsan (GUNSAN 01-GUNSAN 11) and the Atlantic (ATLANTIC 12-ATLANTIC 22) from two geographic populations of tonguesoles. The shortest genetic distance displaying significant molecular difference was between individuals' GUNSAN no. 02-GUNSAN no. 01 (genetic distance=0.038). In the long run, individual no. 02 of the ATLANTIC tonguesole was most distantly related to GUNSAN no. 06 (genetic distance=0.958). These results demonstrate that the Gunsan tonguesole population is genetically different from the Atlantic tonguesole population. The potential of PCR analysis to identify diagnostic markers for the identification of two tonguesole populations has been demonstrated. As a rule, using various oligonucleotides primers, this PCR method has been applied to identify polymorphic/specific markers particular to species and geographical population, as well as genetic diversity/polymorphism in diverse species of organisms.

Long non-coding RNAs: key regulators of liver and kidney fibrogenesis

  • Su-hyang Han;Je Yeong Ko;Eun Seo Kang;Jong Hoon Park;Kyung Hyun Yoo
    • BMB Reports
    • /
    • v.56 no.7
    • /
    • pp.374-384
    • /
    • 2023
  • Fibrosis is a pathological condition that is characterized by an abnormal buildup of extracellular matrix (ECM) components, such as collagen, in tissues. This condition affects various organs of the body, including the liver and kidney. Early diagnosis and treatment of fibrosis are crucial, as it is a progressive and irreversible process in both organs. While there are certain similarities in the fibrosis process between the liver and kidney, there are also significant differences that must be identified to determine molecular diagnostic markers and potential therapeutic targets. Long non-coding RNAs (lncRNAs), a class of RNA molecules that do not code for proteins, are increasingly recognized as playing significant roles in gene expression regulation. Emerging evidence suggests that specific lncRNAs are involved in fibrosis development and progression by modulating signaling pathways, such as the TGF-β/Smad pathway and the β-catenin pathway. Thus, identifying the precise lncRNAs involved in fibrosis could lead to novel therapeutic approaches for fibrotic diseases. In this review, we summarize lncRNAs related to fibrosis in the liver and kidney, and propose their potential as therapeutic targets based on their functions.

Evaluation of Usefulness of Portal Image Using Electronic Portal Imaging Device (EPID) in the Patients Who Received Pelvic Radiation Therapy (골반강 내 방사선 치료 환자에서 Electronic Portal Imaging Device(EPID)를 이용한 Portal Image의 유용성에 관한 연구)

  • Kim Woo Chul;Park Won;Kim Heon Jong;Park Seong Young;Cho Young Kap;Loh John J;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.497-504
    • /
    • 1998
  • Purpose : To evaluate the usefulness of electronic portal imaging device through objective compare of the images acquired using an EPID and a conventional port film Materials and Methods : From Apr. to Oct. 1997, a total of 150 sets of images from 20 patients who received radiation therapy in the pelvis area were evaluated in the Inha University Hospital and Severance Hospital. A dual image recording technique was devised to obtain both electronic portal images and port film images simultaneously with one treatment course. We did not perform double exposure five to ten images were acquired from each patient. All images were acquired from posteroanterior (PA) view except images from two patients. A dose rate of 100-300 Mu/min and a 10-MV X-ray beam were used and 2-10 MUs were required to produce a verification image during treatment. Kodak diagnostic film with metal/film imaging cassette which was located on the top of the EPID detector was used for the port film. The source to detector distance was 140 cm. Eight anatomical landmarks (pelvic brim, sacrum, acetabulum. iliopectineal line, symphysis, ischium, obturator foramen, sacroiliac joint) were assessed. Four radiation oncologist joined to evaluate each image. The individual landmarks in the port film or in the EPID were rated - very clear (1), clear (2), visible (3), not clear (4), not visible (5). Results : Using an video camera based EPID system. there was no difference of image quality between no enhanced EPID images and port film images. However, when we provided some change with window level for the portal image, the visibility of the sacrum and obturator foramen was improved in the portal images than in the port film images. All anatomical landmarks were more visible in the portal images than in the port film when we applied the CLAHE mode enhancement. The images acquired using an matrix ion chamber type EPID were also improved image qualify after window level adjustment. Conclusion : The quality of image acquired using an electronic portal imaging device was comparable to that of the port film. When we used the enhance mode or window level adjustment. the image quality of the EPID was superior to that of the port film. EPID may replace the port film.

  • PDF