• Title/Summary/Keyword: Diagnostic Information

Search Result 1,428, Processing Time 0.025 seconds

A Study on Diagnosis of the Bianque's School (편작학파(扁鵲學派)의 진단(診斷)에 관한(關) 연구(硏究))

  • Kim, Seong-ho;Bang, Min-woo;Lee, Byung-wook;Kim, Ki-woo
    • Journal of Korean Medical classics
    • /
    • v.31 no.3
    • /
    • pp.33-58
    • /
    • 2018
  • Objectives : Literatures related to Bianque are studied to discover the path of development and the impact of Bianque school's pulse diagnosis system. Methods : Texts regarding Bianque were searched in history books such as Shiji and Zhanguoce, and medical texts such as the medical books of Mawangdui Han Tomb, Huangdineijng, Maijing, and Qianjinyifang to understand how the Bianque school's pulse diagnosis system was developed. Results : 1. Bianque school's pulse diagnosis system was used to inspect the distribution pattern of blood vessels and discover the location of the disease including the palpatation realm such as only hard or only fall. 2. The system of inspection was created when the diagnosis method that uses the color of the pulse by using the color of blood vessels was added to the diagnostic method of pulse condition. 3. Adding the concept of pulse to the visual information that derives from pulse condition becomes pulsation. This is a diagnostic method that falls under the realm of palpation, and it was used to discover the location of disease. 4. The qi of pulse is motor that induces pulse, and this concept is used in order to understand how normal and abnormal pulsations appear, and to treat the circulation disorder of qi and blood. 5. Cubit skin examination is a method that comprehensively take into account the upper arm skin's cold and heat, slippery and roughness, and relax and tension state. This method was used together with other diagnostic methods. As described above, it seems that the diagnostic method with blood vessels used by Bianque school seems to have developed from Bianque's special inspection ability to the stage where it uses palpation, and then to the stage of cubit skin examination which uses both palpation and inspection.

Assessment of the Intracranial Stents Patency and Re-Stenosis by 16-Slice CT Angiography with Optimized Sharp Kernel : Preliminary Study

  • Choo, Ki-Seok;Lee, Tae-Hong;Choi, Chang-Hwa;Park, Kyung-Pil;Kim, Chang-Won;Kim, Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.284-288
    • /
    • 2009
  • Objective : Our retrospective study aimed to determine whether 16-slice computerized tomography (CT) angiography optimized sharp kernel is suitable for the evaluation of visibility, luminal patency and re-stenosis of intracranial stents in comparison with conventional angiography. Methods : Fifteen patients with symptomatic intracranial stenotic lesions underwent balloon expandable stent deployment of these lesions (10 middle cerebral arteries, 2 intracranial vertebral arteries, and 3 intracranial internal carotid arteries). CT angiography follow-up ranged from 6 to 15 months (mean follow-up, 8 months) after implantation of intracranial stents and conventional angiography was confirmed within 2 days. Curved multiplanar reformations with maximal intensity projection (MIP) with optimal window settings for assessment of lumen of intracranial stents were evaluated for visible lumen diameter, stent patency (contrast distal to the stent as an indirect sign), and re-stenosis by two experienced radiologists who blinded to the reports from the conventional angiography. Results : All of stents deployed into symptomatic stenotic lesions. All stents were classified as patent and no re-stenosis, which was correlated with results of conventional angiography. Parts of the stent lumen could be visualized in all cases. On average, 57% of the stent lumen diameter was visible using optimized sharp kernel. Significant improvement of lumen visualization (22%, p<0.01) was observed using the optimized sharp kernel compared with the standard sharp kernel. Inter-observer agreements on the measurement of lumen diameter and density were judged as good, respectively (p<0.05). Conclusion : Sixteen-slice CT using the optimized sharp kernel may provide a useful information for evaluation of lumen diameter patency, and re-stenosis of intracranial stents.

Statistical Techniques based Computer-aided Diagnosis (CAD) using Texture Feature Analysis: Applied of Cerebral Infarction in Computed Tomography (CT) Images

  • Lee, Jaeseung;Im, Inchul;Yu, Yunsik;Park, Hyonghu;Kwak, Byungjoon
    • Biomedical Science Letters
    • /
    • v.18 no.4
    • /
    • pp.399-405
    • /
    • 2012
  • The brain is the body's most organized and controlled organ, and it governs various psychological and mental functions. A brain abnormality could greatly affect one's physical and mental abilities, and consequently one's social life. Brain disorders can be broadly categorized into three main afflictions: stroke, brain tumor, and dementia. Among these, stroke is a common disease that occurs owing to a disorder in blood flow, and it is accompanied by a sudden loss of consciousness and motor paralysis. The main types of strokes are infarction and hemorrhage. The exact diagnosis and early treatment of an infarction are very important for the patient's prognosis and for the determination of the treatment direction. In this study, texture features were analyzed in order to develop a prototype auto-diagnostic system for infarction using computer auto-diagnostic software. The analysis results indicate that of the six parameters measured, the average brightness, average contrast, flatness, and uniformity show a high cognition rate whereas the degree of skewness and entropy show a low cognition rate. On the basis of these results, it was suggested that a digital CT image obtained using the computer auto-diagnostic software can be used to provide valuable information for general CT image auto-detection and diagnosis for pre-reading. This system is highly advantageous because it can achieve early diagnosis of the disease and it can be used as supplementary data in image reading. Further, it is expected to enable accurate medical image detection and reduced diagnostic time in final-reading.

Oriental Pulse Diagnostic Apparatus with an emphasis on sense on fingers (수지부 감각정보에 중점을 둔 한의학적 전자 맥진 시스템에 대한 고찰)

  • Kim, Byoung-Chul;Chae, Han
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • This study aims to develop a system for diagnosing pulse and disease conditions based on oriental medical classics to collect objective quantitative information in the traditional pulse examination environment that uses fingers. For this purpose, the study suggested a thimble-type sensor unit as the most appropriate pulse analyzer and proposed a traditional method to measure the pulse pressure wave on the spots of cheok, gwan and chon by installing the pulse analyzer on the forefinger, middle finger and medical finger. Then, it was interpretively found that this pulse analyzer enables us to objectively recognize 28 pulses defined in Oriental medical classics including the yukjo pulse, described as the buchimjisak-heosil pulse, and the hong, yoo, hyeok and san pulses. Finally, the study proposed a method to extract key parameters essential to pulse condition diagnosis from the pulse pressure wave measured by this pulse analyzer.

  • PDF

Second Opinion Diagnoses of Cytologic Specimens on Consultation : Asan Medical Center Experience (세포 병리 자문 재판독의 진단 불일치에 관한 연구: 서울아산병원의 경험)

  • Park, So-Hyung;Ro, Jae-Y.;Cho, Kyung-Ja;Gong, Gyung-Yub;Cho, Yong-Mee;Khang, Shin-Kwang
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2008
  • Background : Second opinion diagnosis of outside pathology slides is a common practice for efficient and proper patient management. We analyzed cytology slides from outside hospitals submitted for a second opinion diagnosis to determine whether the second opinion diagnosis had any influence on patient care. Methods : We reviewed 1,153 outside cytology slides referred to Asan Medical Center for second opinions from January, 2007, to December, 2007. All cases were categorized into three groups; no diagnostic discrepancy, minor diagnostic discrepancies (no impact on the management), and major diagnostic discrepancies (significant impact on the management and subsequent follow-up). Results : The thyroid was the most common organ system (933 cases, 80.9%), Forty cases (3.6%) belonged to the major diagnostic discrepancy group and 149 cases (12.8%) to the minor discrepancy group. For validation of second opinion diagnoses in major discrepancy cases, subsequent biopsy or surgical resection specimens and clinical information were reviewed, which were available in 29 cases. The second opinion diagnoses resulted in alteration of clinical management in 21 of 29 cases. Conclusion : For all referred patients, second opinion diagnosis is important and mandatory for appropriate patient care.

Development of Diagnosis System about Services and Infrastructure for Rural Welfare and Culture (농촌 복지·문화 서비스 및 인프라 진단체계 개발)

  • Kim, Soo-Jin;Bae, Seung-Jong;Kim, Dae-Sik;Im, Sang-Bong
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.1
    • /
    • pp.51-65
    • /
    • 2019
  • This study developed diagnostic system to understand the level of welfare cultural service and infrastructure in rural areas. The applicability was reviewed through the Delphi survey and the sample survey of 60 villages. The diagnostic indicators consist of three areas: the demand area, supply area, and delivery area. The demand area consists of 8 indicators, 25 indicators for welfare services and infrastructure (healthcare, social welfare) and 32 indicators for cultural services and infrastructure (culture, education, leisure sports). The service delivery area was divided into service supply area access and traffic accessibility (public transport use status and rural transport model status) by each indicator. A diagnostic system was applied to 60 villages. Services and infrastructure for rural welfare and culture were supplied more in the Si area than Gun area. The delivery area was easier to access the Gun area than Si area. In the case of traffic access, public transportation was more frequently used in the Si area than Gun area, and the rural transportation model was found to have a relatively large amount in the Gun area compared to Si area. The diagnosis system about services and infrastructure for rural welfare and culture will provide information necessary for establishment and decision making of regional development policy taking into account characteristics of rural areas in the future.

Analysis of the Correlation Between Sarcopenia and Locomotive Syndrome in the Elderly in Korea (국내 노인의 근감소증과 운동기능저하증후군에 대한 분석 연구)

  • Kim, Myung-Chul;Cheon, Ji-Yeon;Kim, Hae-In;Chung, Dong-Kun;Bae, Won-Sik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.2
    • /
    • pp.1-11
    • /
    • 2022
  • Purpose : This study was conducted to assess the status of sarcopenia and locomotive syndrome in the Korean elderly population over 65 years of age by applying the recently updated screening tool for diagnostic evaluation of sarcopenia and locomotive syndrome. Methods : Sarcopenia and locomotive syndrome (LS) were diagnosed and evaluated in 210 Korean elderly people over 65 years of age. There were 36 patients in the "sarcopenia group", 164 in the "locomotive syndrome group", and 10 in the "normal group". The collected data were analyzed using the chi-square and Kruskal-Wallis tests. Results : The diagnostic evaluation of sarcopenia and LS showed the presence of sarcopenia in 9.05 % of males and 8.10% females among the Korean elderly population over 65 years of age. Prevalence of stage 1 locomotive syndrome (LS 1) was 95.24 %; stage 2, (LS 2) 36.19 %; and stage 3 (LS 3), 16.19 % among the study population. Both the sarcopenia diagnostic indicator and the LS evaluation indicators showed significant differences between the three groups. All the subjects in the sarcopenia group had LS; further, on comparison of the detailed composition ratio of each patient with LS, the prevalence of LS in the sarcopenia group was found to be: LS 1 41.67 %, LS 2 41.67 %, and LS 3 16.67 %, whereas in the LS group, it was found to be: LS 1 66.46 %, LS 2 16.46 %, and LS 3 17.07 %. The difference between the two groups was statistically significant. Conclusion : It was confirmed that sarcopenia is correlated with LS incidence. This suggests that the evaluation of motor LS can be used as a tool for the early diagnosis and prevention of sarcopenia in cases of functional decline due to aging in the elderly population.

Validity of the diagnosis of diabetic microvascular complications in Korean national health insurance claim data

  • Kim, Hyung Jun;Park, Moo-Seok;Kim, Jee-Eun;Song, Tae-Jin
    • Annals of Clinical Neurophysiology
    • /
    • v.24 no.1
    • /
    • pp.7-16
    • /
    • 2022
  • Background: There is inadequate information on the validation of diabetic microvascular complications in the Korean National Health Insurance Service data set. We aimed to validate the diagnostic algorithms regarding the nephropathy, neuropathy, and retinopathy of diabetes. Methods: From various secondary and tertiary medical centers, we selected 6,493 patients aged ≥ 40 years who were diagnosed with diabetic microvascular complications more than once based on codes in the 10th version of the International Classification of Diseases (ICD-10). During 2019 and 2020, we randomly selected the diagnoses of 200 patients, 100 from each of two hospitals. The positive predictive value (PPV), negative predictive value, error rate, sensitivity, and specificity were determined for each diabetic microvascular complication according to the ICD-10 codes, laboratory findings, diagnostic studies, and treatment procedure codes. Results: Among the 200 patients who visited the hospital more than once and had the diagnostic codes of diabetic microvascular complications, 142, 110, and 154 patients were confirmed to have the gold standard of diabetic nephropathy (PPV, 71.0%), diabetic neuropathy (PPV, 55.0%), and diabetic retinopathy (PPV, 77.0%), respectively. The PPV and specificity of diabetic nephropathy (PPV, 71.0-81.4%; specificity, 10.3-53.4%), diabetic neuropathy (PPV, 55.0-81.3%; specificity, 66.7-76.7%) and diabetic retinopathy (PPV, 77.0-96.6%; specificity, 2.2-89.1%) increased after combining them with the laboratory findings, diagnostic studies, and treatment procedures codes. These change trends were observed similarly for both hospitals. Conclusions: Defining diabetic microvascular complications using ICD-10 codes and their related examination codes may be a feasible method for studying diabetic complications.

A measure of discrepancy based on margin of victory useful for the determination of random forest size (랜덤포레스트의 크기 결정에 유용한 승리표차에 기반한 불일치 측도)

  • Park, Cheolyong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.3
    • /
    • pp.515-524
    • /
    • 2017
  • In this study, a measure of discrepancy based on MV (margin of victory) has been suggested that might be useful in determining the size of random forest for classification. Here MV is a scaled difference in the votes, at infinite random forest, of two most popular classes of current random forest. More specifically, max(-MV,0) is proposed as a reasonable measure of discrepancy by noting that negative MV values mean a discrepancy in two most popular classes between the current and infinite random forests. We propose an appropriate diagnostic statistic based on this measure that might be useful for the determination of random forest size, and then we derive its asymptotic distribution. Finally, a simulation study has been conducted to compare the performances, in finite samples, between this proposed statistic and other recently proposed diagnostic statistics.

Time-Frequency Analysis Using Linear Combination Wavelet Transform and Its Application to Diagnostic Monitoring System (선형조합 웨이브릿 변환을 사용한 시간-주파수 분석 및 진단 모니터링 시스템의 적용)

  • 김민수;권기룡;김석태
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.1
    • /
    • pp.83-95
    • /
    • 1999
  • Wavelet transform has localization for time or frequency. It is useful to analyze a nonstationary signal. Basic function on wavelet transform is generated dilating and translating the original wavelet(mother wavelet). In this paper, time-frequency analysis method using linear combination wavelet transform is proposed. And it is applied to diagnostic monitoring system using the proposed linear combination wavelet transform. The stationary and nonstationary signal is used linear chirp signal, fan noise signal, a sinusoid signal from revolution body, electronic signal. Transform applied to signal analysis use fast Fourier transform (FFT), Daubechies, Haar and proposed linear combination method. The result of time-frequency analysis using linear combination wavelet transform is suited for portraying nonstationary time signal as well as stationary signal. Also the diagnostic monitoring system carry out the effective the signal analysis.

  • PDF