• Title/Summary/Keyword: Diagnostic Information

Search Result 1,412, Processing Time 0.036 seconds

Prognostic Factors in Postpsychotic Depressive Disorder of Schizophrenia (정신분열증의 정신증 후 우울장애의 예측인자)

  • Kim, Jin-Sung;Lee, Jong-Bum;Seo, Wan-Seok;Koo, Bon-Hoon;Bae, Dae-Seok;Kim, Yi-Youg;Kim, Jung-Youp
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.150-165
    • /
    • 2005
  • Purpose: This study was conducted to investigate the prognostic factors of postpsychotic depressive symptoms in patients with schizophrenia. Materials and Methods: Eighty patients were selected based on the diagnostic criteria from the DSM-IV, PANSS and ESRS. For all patients information was collected on demographic and clinical characteristics. The subjective depressive symptoms and the objective depressive symptoms, as well as patients insight regarding psychosis were evaluated. The subjective depressive symptoms were evaluated by BDI and ZDS; the objective depressive symptoms were evaluated by HDRS and CDSS, and patient insight into the psychosis was evaluated by KISP. Results: The comparisons using demographic and clinical characteristics showed that HDRS and CDSS had significant difference with regard to gender and suicide attempts; the BDI was associated with difference in education level and age of onset. The patients with scores above cuff-off score for each scale were 20(25.0%) for the BDI, 16(20.0%) for the ZDS, 18(22.5%) for the CDSS and 6(7.5%) for the HDRS. The results of the stepwise multiple regression analysis showed that the scores for the KISP, education levels, gender and suicide attempts were the main prognostic factors in patients with the psychotic depressive disorder of schizophrenia. Conclusion: The main prognostic factors in psychotic depressive disorder of schizophrenia included: insight into psychosis, suicidal attempts. Insight into the psychosis was the most reliable prognostic factor but this characteristic had a negative relationship to the with depressive symptoms.

  • PDF

The taxonomic implication of leaf micromorphological characteristics in the genus Aruncus (Rosaceae) (눈개승마속(장미과) 잎 표피 미세형태학적 형질 및 분류학적 유용성)

  • OAK, Min-Kyeong;SONG, Jun-Ho;HONG, Suk-Pyo
    • Korean Journal of Plant Taxonomy
    • /
    • v.48 no.2
    • /
    • pp.143-152
    • /
    • 2018
  • A comparative study of leaf epidermal microstructures in genus Aruncus (two species, five varieties) was carried out using scanning electron microscopy in order to evaluate their significance in terms of taxonomy. All of the leaves of the taxa studied here were amphistomatic with undulate anticlinal walls, and smooth and flat periclinal walls on both surfaces. The size range of the stomata complex is $8.95-21.97{\times}7.50-16.99{\mu}m$: the largest one was found in Aruncus dioicus var. astilboides (average $18.01{\times}13.47{\mu}m$) and the smallest was measured and determined to be A. gombalanus (average $11.11{\times}8.94{\mu}m$). An anomocytic stomata complex was found in all of the studied taxa. The stomatal frequency on average was $27.54/0.05mm^2$; it is highest in A. gombalanus ($60.4/0.05mm^2$) and lowest in A. dioicus var. acuminatus ($11.6/0.05mm^2$). Two types (short stalked capitate glandular trichome and non-glandular trichome) of trichomes are found in the leaves. The non-glandular trichome was divided into three types based on the presence and degree of development of subsidiary cells. Anomocytic stomata of the hypostomatic type and the distribution pattern of capitate glandular trichomes were the major characters in this genus. The stomata size and frequency, the epidermal cell structure, the trichome type and the distribution pattern may have diagnostic importance among the taxa in the genus. Our leaf micromorphological results provide useful information for the taxonomic revision of the genus Aruncus.

Full mouth rehabilitation for a patient with vertical dimension loss using digital diagnostic analysis: A clinical report (수직고경이 감소된 환자의 디지털 진단 분석을 이용한 완전 구강 회복 증례)

  • Choi, Yeawon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.487-496
    • /
    • 2021
  • Full mouth rehabilitation is re-organizing the occlusion of the remaining teeth and missing teeth considering the functions, esthetics, and neuromuscular harmony. With the loss of multiple teeth, the patient's occlusal plane gradually collapses and the vertical dimension can be reduced. Since reduced vertical dimension can be a potential etiology of the temporomandibular joint and masticatory muscles, prosthetic restoration with increased vertical dimension is required. This case report is about a 68 years old patient with vertical dimension loss due to worn dentition and multiple loss of teeth. In this case, the loss of vertical dimension is assessed carefully using the digital dentistry technology. Using CAD software in digital analysis step, the occlusal plane was established and evaluated using several criteria. Orienting the position of the bone and teeth using CBCT image, patient's condition was visualized in 3 dimension and treatment planning was possible virtually. The information that matches the patient's condylar position with the articulator, which is the virtual face bow, is reproduced on the actual articulator, and evaluated again. After the evaluation, provisional prosthesis was fabricated and it was confirmed that the patient adapts without any abnormality. This was implemented as a final prosthesis. As a result, the patient obtained satisfying results, utilizing the benefits of digital dentistry technology and traditional methods.

Diagnostic Availability of Estrogen Receptor Alpha mRNA on Cervical Cancer Tissue (자궁경부암 조직에서 에스트로겐 수용체 알파 mRNA의 진단적 유용성)

  • Kim, Geehyuk;Yu, Kwangmin;Kim, Jungho;Kim, Seoyong;Park, Sunyoung;Ahn, Sungwoo;Lee, Ji-Young;Kim, Sunghyun;Park, Ho-Hyun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.4
    • /
    • pp.449-456
    • /
    • 2018
  • Cervical cancer is the fourth most frequently diagnosed cancer in women worldwide. In lower Human Development Index countries, it has the second highest incidence and mortality among cancer in women. Therefore, better diagnosis and treatment systems are needed. Among them, estrogen receptor alpha ($ER-{\alpha}$) mRNA expression has been analyzed with RT-qPCR since several studies reported that $ER-{\alpha}$ is necessary in the maturation of the uterus and is related to cervical cancer. In this study, $ER-{\alpha}$ quantitative analysis was performed on various lesions and normal tissue samples. Based on the receiver operating characteristic (ROC) curve, its sensitivity and specificity were 85% and 75%, respectively, showing higher or similar results to those of conventional HPV tests. In addition, its expression level was analyzed with clinical information. With regression analysis, the R square value between the $ER-{\alpha}$ mRNA expression level and menopause status was 0.5041, indicating a strong correlation. This study was performed as part of a pilot study and suggests that $ER-{\alpha}$ is related to carcinogenesis. Future studies will examine other hormones and menopausal factors with a larger sample size.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Factors that Influence Physician Salary Payment through Analyzing on Internet Invitation Webpage in Korea (초빙광고 자료를 활용한 봉직 의사의 급여수준과 관련요인)

  • Kang, Hyun Goo;Lee, Ji Hyung;Jung, Da-Doo;Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.1
    • /
    • pp.12-22
    • /
    • 2021
  • Backgrounds: Proper distribution and supply of physicians are factors that affect national health care systems. This study investigated the payment distribution levels and the determinants that influence the salary levels of hospital hired physicians. Methods: We analyzed 4,014 job advertisements posted on an internet invitation information site about physician recruitment from May 2016 to May 2019. We used univariate analysis to determine the relationship between average monthly salary and the other related variables. Multiple regression analysis was used to determine the predictors of physician salary level. Results: The average monthly salary for the service physician was 15.4 million won, highest for orthopedic surgeons with 22.24 million won, and lowest for diagnostic laboratory physician with 11.4 million won. The factors significantly associated with average monthly salary were; non-major specialty, housing provision, no severance pay, and incentives(p<0.05). Non-major specialty, incentives, and the regions were predictors of the average standardized monthly salary(p<0.05). Conclusion: Factors associated with average monthly salary as revealed by this study were; medical specialty, hospital regional location, housing provision, payment of retirement allowance, and payment of other incentives respectively. However, this study was a cross-sectional study, and further studies will be required.

Does an extensive diagnostic workup for upfront resectable pancreatic cancer result in a delay which affects survival? Results from an international multicentre study

  • Thomas B. Russell;Peter L. Labib;Jemimah Denson;Fabio Ausania;Elizabeth Pando;Keith J. Roberts;Ambareen Kausar;Vasileios K. Mavroeidis;Gabriele Marangoni;Sarah C. Thomasset;Adam E. Frampton;Pavlos Lykoudis;Manuel Maglione;Nassir Alhaboob;Hassaan Bari;Andrew M. Smith;Duncan Spalding;Parthi Srinivasan;Brian R. Davidson;Ricky H. Bhogal;Daniel Croagh;Ashray Rajagopalan;Ismael Dominguez;Rohan Thakkar;Dhanny Gomez;Michael A. Silva;Pierfrancesco Lapolla;Andrea Mingoli;Alberto Porcu;Teresa Perra;Nehal S. Shah;Zaed Z. R. Hamady;Bilal Al-Sarrieh;Alejandro Serrablo;Somaiah Aroori
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.4
    • /
    • pp.403-414
    • /
    • 2023
  • Backgrounds/Aims: Pancreatoduodenectomy (PD) is recommended in fit patients with a carcinoma (PDAC) of the pancreatic head, and a delayed resection may affect survival. This study aimed to correlate the time from staging to PD with long-term survival, and study the impact of preoperative investigations (if any) on the timing of surgery. Methods: Data were extracted from the Recurrence After Whipple's (RAW) study, a multicentre retrospective study of PD outcomes. Only PDAC patients who underwent an upfront resection were included. Patients who received neoadjuvant chemo-/radiotherapy were excluded. Group A (PD within 28 days of most recent preoperative computed tomography [CT]) was compared to group B (> 28 days). Results: A total of 595 patents were included. Compared to group A (median CT-PD time: 12.5 days, interquartile range: 6-21), group B (49 days, 39-64.5) had similar one-year survival (73% vs. 75%, p = 0.6), five-year survival (23% vs. 21%, p = 0.6) and median time-to-death (17 vs. 18 months, p = 0.8). Staging laparoscopy (43 vs. 29.5 days, p = 0.009) and preoperative biliary stenting (39 vs. 20 days, p < 0.001) were associated with a delay to PD, but magnetic resonance imaging (32 vs. 32 days, p = 0.5), positron emission tomography (40 vs. 31 days, p > 0.99) and endoscopic ultrasonography (28 vs. 32 days, p > 0.99) were not. Conclusions: Although a treatment delay may give rise to patient anxiety, our findings would suggest this does not correlate with worse survival. A delay may be necessary to obtain further information and minimize the number of PD patients diagnosed with early disease recurrence.

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF