• Title/Summary/Keyword: Diagnose

Search Result 2,905, Processing Time 0.028 seconds

A Pilot Study on the Association Sasang Constitutions with Body Segments (사상체질과 신체분절의 연관성에 관한 예비연구)

  • Yoo, Jong-Hyang;Jang, Eun-Su;Kho, Joung-Hyun;Kim, Ho-Seok;Lee, Si-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.73-79
    • /
    • 2008
  • This pilot study aimed to set up a reasonable method for measuring body segments parameters and finding out some useful body segments parameters to diagnose Sasang constitutions. In this study, we have tried to take a secure effort in measuring and diagnosing of Sasang constitutions based on the consensus among Sasang constitution experts. And we also have tried to find out some useful body segments parameters based on the actual data. We measured 9 clinically meaningful body lengths specified by Sasang constitution experts and analyzed these parameters statistically according to each Sasang constitution. We have found that Taeeumin female's ratio of foot length to height was significantly large and Soyangin's ratio was significantly small, but more data are needed to confirm this finding.

  • PDF

The Site Planning of Idyllic Housing Development (전원주택단지 계획에 관한 연구)

  • 구시온;손세욱
    • Journal of the Korean housing association
    • /
    • v.12 no.2
    • /
    • pp.133-142
    • /
    • 2001
  • The development of idyllic housings, is in increasing growth in the suburban areas of Seoul, presents some critical problems such as in sufficient common open space and poor living condition, which are mainly caused by disorderly designed. Through comparing planning indices of idyllic housing, this paper aims to diagnose the condition and causes of those problems and to present some basic issues on improvement direction. The causes of problems can be summarized as the blind point in regulation system, the shortness of planning elements of a housing block which includes road systems and public facilities, and the mismatch of housing type with density, on which includes road systems and public facilities, and the mismatch of housing type with density, on which hereafter improvement suggestion should be focused. And this study suggest the simulation models on an ideal idyllic housing to be applied in our forthcoming idyllic housing of Korea, which can indeed become a generalized alternative to the livable idyllic housing.

  • PDF

Exploratory approach to measuring facility performance in public service facilities (공공서비스시설에서의 시설성능 요인에 대한 탐색적 연구)

  • Lee, So-Young;Shin, Hee-Young
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.284-287
    • /
    • 2009
  • In order to plan and manage public facilities effectively and efficiently, it is necessary to diagnose the current status of facilities and decide the objective features. Performance measurement is to provide managers with the information they need to measure competitive advantages. This paper discusses public facility performance in order to establish the conceptual framework for performance measurement for public facilities. In order to develop the measurement of public facility performance, a pilot study was conducted with facilities managers of facilities management corporation of public districts in Seoul. We investigated how public facilities management teams have assessed their performance and collected data regarding financial aspects, service aspects, community aspects, and building aspects. There is no standard format to measure facility performance since building sizes, programs, community needs widely differ. However, it is necessary to have a more consistent system to measure facility performance. In addition, each public municipal district needs to empower each district facilities management corporation to participate in managerial decisions and budget control.

  • PDF

신호장치 유지보수를 위한 채널별 신호상태분석 알고리즘 개발

  • 윤달환;임제탁
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.3
    • /
    • pp.318-326
    • /
    • 1993
  • It is not easy to diagnose rapidly the cause of trouble in the signal service which is currently provided by the fully electronic switching system such as TDX. To solve these problems, it is necessary to acquire and analyze the service signal. This paper describes the development of PCM acquirer which can analyze the signal characteristics by acquiring the PCM signal in SHW(subhighway). Also an algorithm which analyzes the acquired signal and determines the signal frequency si discussed by using CZT.

  • PDF

The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge (부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단)

  • 김성홍;박재준;김재환
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

A Study on the Improvement of Lifetime with Short-Term Test Method of AC PDP (AC PDP의 장수명 인자의 단시간 시험 방법에 의한 수명 증대 기술에 관한 연구)

  • Kim, Yun-Gi;Choi, Min-Seok;Lyu, Seong-Nam;Park, Cha-Soo;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1576-1578
    • /
    • 2001
  • In this paper, a short-term test method to diagnose and estimate the lifetime of AC PDP(Plasma Display Panel) has been proposed. As using this method, we investigated the lifetime of MgO layer in AC PDP. The lifetime was increased in proportion to an MgO thickness but it was allowed when the MgO thickness was raised until 5000$\AA$. Over 5000$\AA$, the lifetime was saturated with a thickness of MgO layer.

  • PDF

A Proposal of On-line Management Method for Distribution Transformer using Loss-of-life Calculation (수명 손실 계산을 이용한 온라인 배전용 변압기 관리 방안 제시)

  • Kim, Dong-Hyun;Kim, Jae-Chul;Choi, Joon-Ho;Kim, Oun-Seok;Yun, Yong-Han;Min, Kyeoung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.61-63
    • /
    • 2000
  • As increasing the failure of distribution transformers, we need to manage them efficiently. This paper proposes the method for distribution transformer's management using loss-of-life calculation. The Data Acquisition System(DAS) was developed to manage transformers and the HDLC protocol applied to the system. It will be feasible application to diagnose distribution transformers by checking load conditions such as top oil temperature, ambient temperature, load current, etc. and using loss-of-life calculation.

  • PDF

Multiple foreign bodies causing an orocutaneous fistula of the cheek

  • Kim, Woo Ju;Kim, Woo Seob;Kim, Han Koo;Bae, Tae Hui
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.139-142
    • /
    • 2018
  • Foreign bodies impacted in the maxillofacial region are often a diagnostic challenge. They can be a source of chronic inflammatory reactions and infections leading to the formation of an orocutaneous fistula. Such orocutaneous fistulas cause significant morbidity in most patients, eventually requiring surgery. Recently, we encountered a very rare case of an orocutaneous fistula caused by multiple foreign bodies in the cheek. Precise removal of the foreign bodies was required, and a double-sided anterolateral thigh free flap was used to reconstruct the defect. Surgeons should be aware of the complications of multiple foreign bodies and should be able to diagnose these on careful clinical examination.

Paradoxical Reactions following Intravenous Midazolam in Patients with Severe Anxiety for Dental Treatment -A Case Report- (치과 치료에 대한 심한 공포가 있는 환자들에서 미다졸람 정주 후 나타난 기이반응 -증례보고-)

  • O, Se-Ri
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2009
  • Intravenous midazolam has been frequently used for the relief of anxiety in dental treatment. This is likely the result of the sedative and anterograde amnestic properties of midazolam that are mediated through $\gamma$-Aminobutyric acid agonism. Unfortunately, Paradoxical reactions to midazolam include agitation, talkativeness, confusion, disinhibition, aggression,violent behavior, act of self-injury and need for restraints. These occur in less than 1% of all patients receiving midazolam, may occur at variable times after administration and are difficult to predict and diagnose. Two women with severe anxiety for dental treatment experienced paradoxical reactions associated with the use of intravenous midazolam. We are reviewed the management and prevention of paradoxical reactions and its different etiology.

  • PDF

The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System (적외선 열화상 카메라를 이용한 수전설비 온도분포해석)

  • Jeong, Seung-Cheon;Lim, Yeung-Bae;Kim, Jong-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF