• Title/Summary/Keyword: Dia Analysis

Search Result 73, Processing Time 0.025 seconds

Detection of Variable Stars in the Open Cluster M11 Using Difference Image Analysis Pipeline

  • Lee, Chung-Uk;Koo, Jae-Rim;Kim, Seung-Lee;Lee, Jae-Woo;Park, Byeong-Gon;Han, Cheong-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.289-307
    • /
    • 2010
  • We developed a photometric pipeline to be used for a wide field survey. This pipeline employs the difference image analysis (DIA) method appropriate for the photometry of star dense field such as the Galactic bulge. To verify the performance of pipeline, the observed dataset of the open cluster M11 was re-processed. One hundred seventy eight variable stars were newly discovered by analyzing the light curves of which photometric accuracy was improved through the DIA. The total number of variable stars in the M11 observation region is 335, including 157 variable stars discovered by previous studies. We present the catalogue and light curves for the 178 variable stars. This study shows that the photometric pipeline using the DIA is very useful in the detection of variable stars in a cluster.

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF

Software Development for Dynamic Positron Emission Tomography : Dynamic Image Analysis (DIA) Tool (동적 양전자방출단층 영상 분석을 위한 소프트웨어 개발: DIA Tool)

  • Pyeon, Do-Yeong;Kim, Jung-Su;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.369-376
    • /
    • 2016
  • Positron Emission Tomography(PET) is nuclear medical tests which is a combination of several compounds with a radioactive isotope that can be injected into body to quantitatively measure the metabolic rate (in the body). Especially, Phenomena that increase (sing) glucose metabolism in cancer tissue using the $^{18}F$-FDG (Fluorodeoxyglucose) is utilized widely in cancer diagnosis. And then, Numerous studies have been reported that incidence seems high availability even in the modern diagnosis of dementia and Parkinson's (disease) in brain disease. When using a dynamic PET iamge including the time information in the static information that is provided for the diagnosis many can increase the accuracy of diagnosis. For this reason, clinical researchers getting great attention but, it is the lack of tools to conduct research. And, it interfered complex mathematical algorithm and programming skills for activation of research. In this study, in order to easy to use and enable research dPET, we developed the software based graphic user interface(GUI). In the future, by many clinical researcher using DIA-Tool is expected to be of great help to dPET research.

Evaluation of Gestational Age Median Value by Use of the Quad Test with Dimeric Inhibin A for Korea Pregnant Women (Inhibin-A를 추가한 Quad Test의 한국인 산모의 임신주수별 Median치에 대한 평가)

  • Yoo, Ja-Young;Choi, Sam-Kyu;Cho, Young-Suk;Hwang, Do-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • Human chorionic gonadotrophin (hCG) and unconjugated estriol (uE3) were added to AFP to make what is commonly known as the Triple test. The Triple test combines results from these three tests and has been a standard screening procedure for several years. Recent studies have demonstrated the usefulness of adding inhibin-A to Down's syndrome risk assessment. The Quad test adds dimeric Inhibin-A (DIA) to the three other markers and uses the same computer program to calculate risk factors. Testing was performed between 14 and 21 weeks of gestation. Sample size were 648 samples and period of study was from 1, July, 2004 to 30, September, 2004. Used analytical methods for AFP, hCG and uE3 were radioimmunoassay (RIA) and dimeric inhibin A was enzyme-linked immunosorbent assay (ELISA). Adding dimeric inhibin-A as a fourth marker to the standard triple test increases the detection rate from 62 % to 75 % with a false-positive rate of 5%. The DIA based Quad test has been shown to be the most effective second trimester screening test for Down's syndrome suitable for routine use. Increased DIA values are observed during normal pregnancy where a bimodal pattern response is seen. Values increase during the first trimester, decline after 14 weeks, and re-ascend between 17-25 weeks. Values for DIA may be additionally elevated during a Down's syndrome pregnancy. Dimeric inhibin A is a glycoprotein hormone made by the ovary and placenta. DIA levels are twice as high in Down's syndrome pregnancies. AFP, hCG, and uE3 levels vary with gestational age, and incorrect gestational dating will influence results. DIA levels do not vary substantially with gestational age, resulting in greater screening accuracy. Although the Quad test is an improvement over the Triple test, it is important to underscore the fact that a positive test on both should be done. Most women who initially screen positive will be found to be carrying normal babies when amniocentesis and definitive diagnostic chromosome analysis are done.

  • PDF

Crystal Structure and Comparative Sequence Analysis of GmhA from Colwellia psychrerythraea Strain 34H Provides Insight into Functional Similarity with DiaA

  • Do, Hackwon;Yun, Ji-Sook;Lee, Chang Woo;Choi, Young Jun;Kim, Hye-Yeon;Kim, Youn-Jung;Park, Hyun;Chang, Jeong Ho;Lee, Jun Hyuck
    • Molecules and Cells
    • /
    • v.38 no.12
    • /
    • pp.1086-1095
    • /
    • 2015
  • The psychrophilic organism Colwellia psychrerythraea strain 34H produces extracellular polysaccharide substances to tolerate cold environments. Sedoheptulose 7-phosphate isomerase (GmhA) is essential for producing $\small{D}$-glycero-$\small{D}$-mannoheptose 7-phosphate, a key mediator in the lipopolysaccharide biosynthetic pathway. We determined the crystal structure of GmhA from C. psychrerythraea strain 34H (CpsGmhA, UniProtKB code: Q47VU0) at a resolution of $2.8{\AA}$. The tetrameric structure is similar to that of homologous GmhA structures. Interestingly, one of the catalytic residues, glutamate, which has been reported to be critical for the activity of other homologous GmhA enzymes, is replaced by a glutamine residue in the CpsGmhA protein. We also found differences in the conformations of several other catalytic residues. Extensive structural and sequence analyses reveal that CpsGmhA shows high similarity to Escherichia coli DnaA initiatorassociating protein A (DiaA). Therefore, the CpsGmhA structure reported here may provide insight into the structural and functional correlations between GmhA and DiaA among specific microorganisms.

Bilateral Diagonal 2DLDA Method for Human Face Recognition (얼굴 인식을 위한 쌍대각 2DLDA 방법)

  • Kim, Young-Gil;Song, Young-Jun;Kim, Dong-Woo;Ahn, Jae-Hyeong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.5
    • /
    • pp.648-654
    • /
    • 2009
  • In this paper, a method called bilateral diagonal 2DLDA is proposed for face recognition. Two methods called Dia2DPCA and Dia2DLDA were suggested to reserve the correlations between the variations in the rows and columns of diagonal images. However, these methods work in the row direction of these images. A row-directional projection matrix can be obtained by calculating the between-class and within-class covariance matrices making an allowance for the column variation of alternative diagonal face images. In addition, column-directional projection matrix can be obtained by calculating the between-class and within-class covariance matrices making an allowance for the row variation in diagonal images. A bilateral projection scheme was applied using left and right multiplying projection matrices. As a result, the dimension of the feature matrix and computation time can be reduced. Experiments carried out on an ORL face database show that the proposed method with three different distance measures, namely, Frobenius, Yang and AMD, is more accurate than some methods, such as 2DPCA, B2DPCA, 2DLDA, etc.

The preparation of Al-Si alloy welding rod by the horizontal continuous casting process with the heating mold (가열주형 수평식연속주조법에 의한 Al-Si 합금 용접봉 제조)

  • 김원태;김명한;이보영
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.101-108
    • /
    • 1994
  • The horizontal continuous casting process with the heating mold was adopted for fabricating defect-free 4043 Al alloy rods of 3.2m dia. with mirror surfaces. These rods were drawn into 2.4mm dia. rods for GTAW welding. The GTAW welding tests were carried out by use of these welding rods with 6061 Al alloy as a base metal. After welding, the X-ray tests, tensile strength tests, bending tests, and microstructural analysis of welded zone and HAZ were carried out. The results represented that the welding rods with good surfaces and welding properties could be made by the horizontal continuous casting, and followed by the drawing process.

  • PDF