• Title/Summary/Keyword: Device to Device (D2D)

Search Result 1,734, Processing Time 0.031 seconds

Mixed-mode simulation of transient characteristics of 4H-SiC DMOSFETs - Impact off the interface changes (Mixde-mode simulation을 이용한 4H-SiC DMOSFETs의 계면상태에서 포획된 전하에 따른 transient 특성 분석)

  • Kang, Min-Seok;Choe, Chang-Yong;Bang, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.55-55
    • /
    • 2009
  • Silicon Carbide (SiC) is a material with a wide bandgap (3.26eV), a high critical electric field (~2.3MV/cm), a and a high bulk electron mobility (${\sim}900cm^2/Vs$). These electronic properties allow high breakdown voltage, high frequency, and high temperature operation compared to Silicon devices. Although various SiC DMOSFET structures have been reported so far for optimizing performances. the effect of channel dimension on the switching performance of SiC DMOSFETs has not been extensively examined. In this paper, we report the effect of the interface states ($Q_s$) on the transient characteristics of SiC DMOSFETs. The key design parameters for SiC DMOSFETs have been optimized and a physics-based two-dimensional (2-D) mixed device and circuit simulator by Silvaco Inc. has been used to understand the relationship with the switching characteristics. To investigate transient characteristic of the device, mixed-mode simulation has been performed, where the solution of the basic transport equations for the 2-D device structures is directly embedded into the solution procedure for the circuit equations. The result is a low-loss transient characteristic at low $Q_s$. Based on the simulation results, the DMOSFETs exhibit the turn-on time of 10ns at short channel and 9ns at without the interface charges. By reducing $SiO_2/SiC$ interface charge, power losses and switching time also decreases, primarily due to the lowered channel mobilities. As high density interface states can result in increased carrier trapping, or recombination centers or scattering sites. Therefore, the quality of $SiO_2/SiC$ interfaces is important for both static and transient properties of SiC MOSFET devices.

  • PDF

2D Backtracking Method of Ultrasonic Signal (초음파 신호의 2차원 역추적 방법에 관한 연구)

  • Kyu-Joung Lee;Choong Ho Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.172-177
    • /
    • 2023
  • In this paper, 2-dimensional backtracking method for ultrasonic signals. Ultrasonic sensors are a common technology used in industrial fields as many studies have been conducted on distance measurement and indoor location tracking using transmission and reception devices in pairs. A method for tracking a signal of an arbitrary ultrasonic transmission device on a 2D plane using only a receiver of an ultrasonic signal is proposed. In order to track the ultrasonic signal, the receiver receives the signal by making at least three. The three receivers may calculate a direction and a distance using a time difference in which the ultrasound reception sound is reached. The existing method of tracking signal sources using ultrasonic waves has a problem of time synchronization of devices because the transceivers must be paired or installed independently for each sensor. In order to solve this problem, the distance of the ultrasonic receiver is minimized, and it is configured as one device. The sensor installed as one device may be processed by one operator, thereby solving the time synchronization problem. To increase time difference accuracy, high-speed 32-bit timers with high time resolution can be used to quickly calculate and track distances and directions.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

A 20 GHz Band 1 Watt MMIC Power Amplifier (20 GHz대 1 Watt 고출력증폭 MMIC의 설계 및 제작)

  • 임종식;김종욱;강성춘;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.1044-1052
    • /
    • 1999
  • A 2-stage 1 watt MMIC(Monolithic Microwave Integrated Circuits) HPA(High Power Amplifiers) at 20 GHz band has been designed and fabricated. The $0.15\mu\textrm{m}$ with the width of $400\mu\textrm{m}$for single device pHEMT technology was used for the fabrication of this MMIC HPA. Due to the series feedback technique from source to ground, bias circuits and stabilization circuits on the main microstrip line, the stability factors(Ks) are more than one at full frequency. The independent operation for each stage and excellent S11, S22 less than -20 dB have been obtained by using lange couplers. For beginning the easy design, linear S-parameters have been extracted from the nonlinear equivalent circuit in foundry library, and equivalent circuits of devices at in/output ports were calculated from this S-parameters. The measured performances, which are in well agreement with the predicted ones, showed the MMIC HPA in this paper has the minimum 15 dB of linear gain, -20 dB of reflection coefficients and 31 dBm of output power over 17~25 GHz.

  • PDF

Synthesis and Characterization of Perylene-based Pyrrolopyrone Derivative for Organic Thin Film Transistor

  • Kim, Hyung-Sun;Jung, Sung-Ouk;Kim, Yun-Hi;Do, Lee-Mi;Kwon, Soon-Ki
    • Journal of Information Display
    • /
    • v.6 no.4
    • /
    • pp.1-5
    • /
    • 2005
  • Perylene-based pyrrolopyrone derivative (PPD) was synthesized via condensation reaction with perylenetetracarboxylic dianhydride and 1,2-phenylenediarnine as n-type channel material. The structure of PPD was characterized by spectroscopic methods such FT-IR and $^1H$-NMR. PPD exhibited high thermal stability ($T_{d5wt%}: 560^{\circ}C$) and was found to be soluble only in protonic solvents with high acidity such as methane sulfonic acid and trifluoroacetic acid. The PPD solution showed maximum absorption and emission at 601 and 628 nm, respectively. Thin film transistors were fabricated by vacuum deposition and solution casting method. The electron mobilities of the devices were achieved as high as $0.17{\times}10^{-6}cm^2/Vs$ for vacuum deposited device and $0.4{\times}10^{-6}cm^2/Vs$ for spin coated device, respectively.

The Design of Dual Phase LNB for DBS Receiving (DBS 수신을 위한 Dual Phase LNB 설계)

  • Lim, Yun-Doo;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.3
    • /
    • pp.188-194
    • /
    • 2002
  • DBS is utilized as very useful media in information-oriented society because it covers wide service area and provide high quality services. But DBS needs skill that can receive DBS signal at move. In this paper, it is considered a development of a device to receive DBS and design of a low noise downconverter that use tracking antenna to receive DBS at mobiles unit and ships which navigate in Korea peninsula coast. The structure of dual phase LNB is composed of LNA, BPF, oscillator, mixer, and IF amplifier. And for the position tracking, two input-output phase performed in phase. Measured results showed good performance that with respect to input signal 11.7 GHz~12.2 GHz, noise figure is 0.87 dBmax and conversion gain 62 dB, temperature characterization ${\pm}400$ kHz in respect to - 30 to $60^{\circ}C$, and phase noise -101 dBc/Hz in respect to offset 100 kHz.

  • PDF

4H-SiC Planar MESFET for Microwave Power Device Applications

  • Na, Hoon-Joo;Jung, Sang-Yong;Moon, Jeong-Hyun;Yim, Jeong-Hyuk;Song, Ho-Keun;Lee, Jae-Bin;Kim, Hyeong-Joon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.2
    • /
    • pp.113-119
    • /
    • 2005
  • 4H-SiC planar MESFETs were fabricated using ion-implantation on semi-insulating substrate without recess gate etching. A modified RCA method was used to clean the substrate before each procedure. A thin, thermal oxide layer was grown to passivate the surface and then a thick field oxide was deposited by CVD. The fabricated MESFET showed good contact properties and DC/RF performances. The maximum oscillation frequency of 34 GHz and the cut-off frequency of 9.3 GHz were obtained. The power gain was 10.1 dB and the output power of 1.4 W was obtained for 1 mm-gate length device at 2 GHz. The fabricated MESFETs showed the charge trapping-free characteristics and were characterized by the extracted small-signal equivalent circuit parameters.

A Study on a New Concept for the Structural Strength Assessment to Development of Membrane LNG Cargo Container System under Static Load (멤브레인형 LNG 화물창 개발을 위한 정적 구조 안전성 평가 모델 연구)

  • Hwang, Se Yun;Kim, Yooil;Kang, Joong Kyoo;Lee, Jang Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.2
    • /
    • pp.162-169
    • /
    • 2016
  • A new concept of membrane type LNG CCS was proposed. Also, its static behavior was numerically analyzed considering the interaction between primary and secondary barrier together with securing device. Hull deflection was taken into account as an external load, together with temperature distribution across the barriers. The suggested numerical model considers both sliding and contact between the two mating surfaces of both the primary and secondary barrier, and anisotropic material behavior of plywood, R-PUF was also taken into account. Furthermore, detailed local strength was evaluated for the securing device, which is arranged between two barriers to hold the primary barrier. It was confirmed through the numerical analysis that the new concept of membrane type CCS was structurally safe under static loading condition and securing concept was structurally reliable.

Development of Location based Augmented Reality System for Public Underground Facility Management (공공지하시설물 관리를 위한 증강현실 시스템 개발)

  • Lee, Hyo-Jin;Kim, Ji-Sung;Seo, Ho-Seok;Cho, Young-Sik
    • Journal of Digital Contents Society
    • /
    • v.19 no.2
    • /
    • pp.237-243
    • /
    • 2018
  • Most of public underground facilities are installed under the ground, thus it is difficult to recognize the accurate location even with the drawings. Studies are conducted to understand exact position of underground facilities using augmented reality. However, in those studies, establishing of additional 3D object model database is needed when AR system is used at field. Because most of public underground facility information are established as 2 dimensional. In this study, AR system is developed as mobile application which can use original 2D underground facility data to transfer 3D AR data automatically without additional 3D database establishment.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.